Motorised two-way ball valve.
Product Description
Motorised two-way ball valve.
With auxiliary microswitch.
Actuator torque 15 N·m.
With auxiliary microswitch.
Technical data
Maximum working pressure:
16 bar
Medium temperature range:
-10–110 °C
Ambient temperature range:
-10–55 °C
Protection class:
IP 65
Auxiliary microswitch contact rating (230V):
6 (2) A
△p max.:
10 bar, 5 bar
Operating time:
50 s
Rotation:
90° rotation
Certifications
Download
Drawings and specifications
Part number | Connection | Electric supply | Kv |
---|---|---|---|
638052 | R 3/4" (EN 10226-1) M |
230 V AC | 17 m³/h |
3D models
Tender text
Motorised two-way ball valve. With auxiliary microswitch.
With auxiliary microswitch.
Actuator torque 15 N·m. Connection: R 3/4" (EN 10226-1) M. Maximum working pressure: 16 bar. Medium temperature range: -10–110 °C. Ambient temperature range: -10–55 °C. Electric supply: 230 V AC. Running power consumption: 6 VA. Protection class: IP 65. Auxiliary microswitch contact rating (230V): 6 (2) A. Kv: 17 m³/h. Operating time: 50 s (90° rotation).
SCIP code
e501bc74-cab6-4288-b6aa-f146ce28f273
|
|||
638062 | R 1" (EN 10226-1) M |
230 V AC | 36,5 m³/h |
2D drawings
3D models
Tender text
Motorised two-way ball valve. With auxiliary microswitch.
Actuator torque 15 N·m. Connection: R 1" (EN 10226-1) M. Maximum working pressure: 16 bar. Medium temperature range: -10–110 °C. Ambient temperature range: -10–55 °C. Electric supply: 230 V AC. Running power consumption: 6 VA. Protection class: IP 65. Auxiliary microswitch contact rating (230V): 6 (2) A. Kv: 36,5 m³/h. Operating time: 50 s (90° rotation).
SCIP code
d01731e6-4f8c-4c68-962f-b79ee72a9299
|
|||
638072 | R 1 1/4" (EN 10226-1) M |
230 V AC | 48 m³/h |
3D models
Tender text
Motorised two-way ball valve. With auxiliary microswitch.
Actuator torque 15 N·m. Connection: R 1 1/4" (EN 10226-1) M. Maximum working pressure: 16 bar. Medium temperature range: -10–110 °C. Ambient temperature range: -10–55 °C. Electric supply: 230 V AC. Running power consumption: 6 VA. Protection class: IP 65. Auxiliary microswitch contact rating (230V): 6 (2) A. Kv: 48 m³/h. Operating time: 50 s (90° rotation).
SCIP code
926620bc-6544-49a9-b07a-e9e5839fa8e7
|
|||
638082 | R 1 1/2" (EN 10226-1) M |
230 V AC | 77 m³/h |
2D drawings
3D models
Tender text
Motorised two-way ball valve. With auxiliary microswitch.
Actuator torque 15 N·m. Connection: R 1 1/2" (EN 10226-1) M. Maximum working pressure: 16 bar. Medium temperature range: -10–110 °C. Ambient temperature range: -10–55 °C. Electric supply: 230 V AC. Running power consumption: 6 VA. Protection class: IP 65. Auxiliary microswitch contact rating (230V): 6 (2) A. Kv: 77 m³/h. Operating time: 50 s (90° rotation).
SCIP code
ce93ca03-e3ba-4b93-a419-99964e6334f5
|
|||
638092 | R 2" (EN 10226-1) M |
230 V AC | 140 m³/h |
2D drawings
3D models
Tender text
Motorised two-way ball valve. With auxiliary microswitch.
Actuator torque 15 N·m. Connection: R 2" (EN 10226-1) M. Maximum working pressure: 16 bar. Medium temperature range: -10–110 °C. Ambient temperature range: -10–55 °C. Electric supply: 230 V AC. Running power consumption: 6 VA. Protection class: IP 65. Auxiliary microswitch contact rating (230V): 6 (2) A. Kv: 140 m³/h. Operating time: 50 s (90° rotation).
SCIP code
e97651b6-603d-4a0b-a4db-9a7ec2c160c7
|
|||
638054 | R 3/4" (EN 10226-1) M |
24 V AC | 17 m³/h |
3D models
Tender text
Motorised two-way ball valve. With auxiliary microswitch.
Actuator torque 15 N·m. Connection: R 3/4" (EN 10226-1) M. Maximum working pressure: 16 bar. Medium temperature range: -10–110 °C. Ambient temperature range: -10–55 °C. Electric supply: 24 V AC. Running power consumption: 6 VA. Protection class: IP 65. Auxiliary microswitch contact rating (230V): 6 (2) A. Kv: 17 m³/h. Operating time: 50 s (90° rotation).
SCIP code
3b1deff1-31c6-4bfe-a12d-c6bbb7a976ad
|
|||
638064 | R 1" (EN 10226-1) M |
24 V AC | 36,5 m³/h |
3D models
Tender text
Motorised two-way ball valve. With auxiliary microswitch.
Actuator torque 15 N·m. Connection: R 1" (EN 10226-1) M. Maximum working pressure: 16 bar. Medium temperature range: -10–110 °C. Ambient temperature range: -10–55 °C. Electric supply: 24 V AC. Running power consumption: 6 VA. Protection class: IP 65. Auxiliary microswitch contact rating (230V): 6 (2) A. Kv: 36,5 m³/h. Operating time: 50 s (90° rotation).
SCIP code
72a7d6e4-6d25-427e-8444-8a634155b546
|
|||
638074 | R 1 1/4" (EN 10226-1) M |
24 V AC | 48 m³/h |
3D models
Tender text
Motorised two-way ball valve. With auxiliary microswitch.
Actuator torque 15 N·m. Connection: R 1 1/4" (EN 10226-1) M. Maximum working pressure: 16 bar. Medium temperature range: -10–110 °C. Ambient temperature range: -10–55 °C. Electric supply: 24 V AC. Running power consumption: 6 VA. Protection class: IP 65. Auxiliary microswitch contact rating (230V): 6 (2) A. Kv: 48 m³/h. Operating time: 50 s (90° rotation).
SCIP code
ad3ff286-908c-495b-b8e1-ebc232b07aa6
|
|||
638084 | R 1 1/2" (EN 10226-1) M |
24 V AC | 77 m³/h |
3D models
Tender text
Motorised two-way ball valve. With auxiliary microswitch.
Actuator torque 15 N·m. Connection: R 1 1/2" (EN 10226-1) M. Maximum working pressure: 16 bar. Medium temperature range: -10–110 °C. Ambient temperature range: -10–55 °C. Electric supply: 24 V AC. Running power consumption: 6 VA. Protection class: IP 65. Auxiliary microswitch contact rating (230V): 6 (2) A. Kv: 77 m³/h. Operating time: 50 s (90° rotation).
SCIP code
709adde7-d6dc-41a0-a49b-71cfe1d7620e
|
|||
638094 | R 2" (EN 10226-1) M |
24 V AC | 140 m³/h |
3D models
Tender text
Motorised two-way ball valve. With auxiliary microswitch.
Actuator torque 15 N·m. Connection: R 2" (EN 10226-1) M. Maximum working pressure: 16 bar. Medium temperature range: -10–110 °C. Ambient temperature range: -10–55 °C. Electric supply: 24 V AC. Running power consumption: 6 VA. Protection class: IP 65. Auxiliary microswitch contact rating (230V): 6 (2) A. Kv: 140 m³/h. Operating time: 50 s (90° rotation).
SCIP code
cf4ed957-d612-49e3-ae8b-d1457002d5de
|