Technical data

Maximum working pressure: 10 bar
Medium temperature range: 5–120 °C
Electric supply: 24 V (AC) / (DC)
Power consumption: 1 W
Maximum percentage of glycol: 50 %
Medium: water, glycol solutions
Transmission: RS-485

Certifications

CE
MI004

Drawings and specifications

Part number Connection Nominal flow rate Measure type
3D models
Tender text
Compact direct heat meter for heating solar systems. The metering module is supplied complete with: - pair of temperature probes with immersion pockets; - Y pockets for immersion probes; - electronic integrator with LCD display. Local reading via LCD display/centralised reading via BUS transmission. Connection: G 1/2" A (ISO 228-1) M, union. Maximum working pressure: 10 bar. Medium temperature range: 5–120 °C. Electric supply: 24 V (AC) / (DC). Power consumption: 1 W. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions. Nominal flow rate: 1,5 m³/h. Transmission: RS-485. Measure type: single nozzle.
SCIP code
02d7fc68-9da5-451b-af86-77cebdec727f
2D drawings
Download
Download
3D models
Download
Download
Tender text
Compact direct heat meter for heating solar systems. The metering module is supplied complete with: - pair of temperature probes with immersion pockets; - Y pockets for immersion probes; - electronic integrator with LCD display. Local reading via LCD display/centralised reading via BUS transmission. Connection: G 3/4" A (ISO 228-1) M, union. Maximum working pressure: 10 bar. Medium temperature range: 5–120 °C. Electric supply: 24 V (AC) / (DC). Power consumption: 1 W. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions. Nominal flow rate: 2,5 m³/h. Transmission: RS-485. Measure type: single nozzle.
SCIP code
4632fb5e-3681-406a-aa22-ed23fad31ed5
3D models
Tender text
Compact direct heat meter for heating solar systems. The metering module is supplied complete with: - pair of temperature probes with immersion pockets; - Y pockets for immersion probes; - electronic integrator with LCD display. Local reading via LCD display/centralised reading via BUS transmission. Connection: G 1" A (ISO 228-1) M, union. Maximum working pressure: 10 bar. Medium temperature range: 5–120 °C. Electric supply: 24 V (AC) / (DC). Power consumption: 1 W. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions. Nominal flow rate: 3,5 m³/h. Transmission: RS-485. Measure type: multi-nozzle.
SCIP code
edcfc008-d4d0-4758-8a48-b8a9a91a905a
3D models
Tender text
Compact direct heat meter for heating solar systems. The metering module is supplied complete with: - pair of temperature probes with immersion pockets; - Y pockets for immersion probes; - electronic integrator with LCD display. Local reading via LCD display/centralised reading via BUS transmission. Connection: G 1 1/4" A (ISO 228-1) M, union. Maximum working pressure: 10 bar. Medium temperature range: 5–120 °C. Electric supply: 24 V (AC) / (DC). Power consumption: 1 W. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions. Nominal flow rate: 6 m³/h. Transmission: RS-485. Measure type: multi-nozzle.
SCIP code
1db3ff43-236b-4ffb-b95b-b4c979570b56
3D models
Tender text
Compact direct heat meter for heating solar systems. The metering module is supplied complete with: - pair of temperature probes with immersion pockets; - Y pockets for immersion probes; - electronic integrator with LCD display. Local reading via LCD display/centralised reading via BUS transmission. Connection: G 1 1/2" A (ISO 228-1) M, union. Maximum working pressure: 10 bar. Medium temperature range: 5–120 °C. Electric supply: 24 V (AC) / (DC). Power consumption: 1 W. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions. Nominal flow rate: 10 m³/h. Transmission: RS-485. Measure type: multi-nozzle.
SCIP code
10449ebe-c9d7-4003-bc0d-323d29007172
3D models
Tender text
Compact direct heat meter for heating solar systems. The metering module is supplied complete with: - pair of temperature probes with immersion pockets; - Y pockets for immersion probes; - electronic integrator with LCD display. Local reading via LCD display/centralised reading via BUS transmission. Connection: G 2" A (ISO 228-1) M, union. Maximum working pressure: 10 bar. Medium temperature range: 5–120 °C. Electric supply: 24 V (AC) / (DC). Power consumption: 1 W. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions. Nominal flow rate: 15 m³/h. Transmission: RS-485. Measure type: multi-nozzle.
SCIP code
90696bf0-a03e-4e7b-817a-758a427adb8f