CONTECA® EASY SOLAR, Compact direct heat meter for heating solar systems.
Product Description
Compact direct heat meter for heating solar systems.
The metering module is supplied complete with:
- pair of temperature probes with immersion pockets;
- Y pockets for immersion probes;
- electronic integrator with LCD display.
Local reading via LCD display/centralised reading via BUS transmission.
Technical data
Maximum working pressure:
10 bar
Medium temperature range:
5–120 °C
Electric supply:
24 V (AC) / (DC)
Power consumption:
1 W
Maximum percentage of glycol:
50 %
Medium:
water, glycol solutions
Transmission:
RS-485
Certifications
Download
Drawings and specifications
Part number | Connection | Nominal flow rate | Measure type |
---|---|---|---|
750254 | G 1/2" A (ISO 228-1) M union |
1,5 m³/h | single nozzle |
3D models
Tender text
Compact direct heat meter for heating solar systems. The metering module is supplied complete with:
- pair of temperature probes with immersion pockets;
- Y pockets for immersion probes;
- electronic integrator with LCD display.
Local reading via LCD display/centralised reading via BUS transmission. Connection: G 1/2" A (ISO 228-1) M, union. Maximum working pressure: 10 bar. Medium temperature range: 5–120 °C. Electric supply: 24 V (AC) / (DC). Power consumption: 1 W. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions. Nominal flow rate: 1,5 m³/h. Transmission: RS-485. Measure type: single nozzle.
SCIP code
02d7fc68-9da5-451b-af86-77cebdec727f
|
|||
750255 | G 3/4" A (ISO 228-1) M union |
2,5 m³/h | single nozzle |
2D drawings
3D models
Tender text
Compact direct heat meter for heating solar systems. The metering module is supplied complete with:
- pair of temperature probes with immersion pockets;
- Y pockets for immersion probes;
- electronic integrator with LCD display.
Local reading via LCD display/centralised reading via BUS transmission. Connection: G 3/4" A (ISO 228-1) M, union. Maximum working pressure: 10 bar. Medium temperature range: 5–120 °C. Electric supply: 24 V (AC) / (DC). Power consumption: 1 W. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions. Nominal flow rate: 2,5 m³/h. Transmission: RS-485. Measure type: single nozzle.
SCIP code
4632fb5e-3681-406a-aa22-ed23fad31ed5
|
|||
750256 | G 1" A (ISO 228-1) M union |
3,5 m³/h | multi-nozzle |
3D models
Tender text
Compact direct heat meter for heating solar systems. The metering module is supplied complete with:
- pair of temperature probes with immersion pockets;
- Y pockets for immersion probes;
- electronic integrator with LCD display.
Local reading via LCD display/centralised reading via BUS transmission. Connection: G 1" A (ISO 228-1) M, union. Maximum working pressure: 10 bar. Medium temperature range: 5–120 °C. Electric supply: 24 V (AC) / (DC). Power consumption: 1 W. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions. Nominal flow rate: 3,5 m³/h. Transmission: RS-485. Measure type: multi-nozzle.
SCIP code
edcfc008-d4d0-4758-8a48-b8a9a91a905a
|
|||
750257 | G 1 1/4" A (ISO 228-1) M union |
6 m³/h | multi-nozzle |
3D models
Tender text
Compact direct heat meter for heating solar systems. The metering module is supplied complete with:
- pair of temperature probes with immersion pockets;
- Y pockets for immersion probes;
- electronic integrator with LCD display.
Local reading via LCD display/centralised reading via BUS transmission. Connection: G 1 1/4" A (ISO 228-1) M, union. Maximum working pressure: 10 bar. Medium temperature range: 5–120 °C. Electric supply: 24 V (AC) / (DC). Power consumption: 1 W. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions. Nominal flow rate: 6 m³/h. Transmission: RS-485. Measure type: multi-nozzle.
SCIP code
1db3ff43-236b-4ffb-b95b-b4c979570b56
|
|||
750258 | G 1 1/2" A (ISO 228-1) M union |
10 m³/h | multi-nozzle |
3D models
Tender text
Compact direct heat meter for heating solar systems. The metering module is supplied complete with:
- pair of temperature probes with immersion pockets;
- Y pockets for immersion probes;
- electronic integrator with LCD display.
Local reading via LCD display/centralised reading via BUS transmission. Connection: G 1 1/2" A (ISO 228-1) M, union. Maximum working pressure: 10 bar. Medium temperature range: 5–120 °C. Electric supply: 24 V (AC) / (DC). Power consumption: 1 W. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions. Nominal flow rate: 10 m³/h. Transmission: RS-485. Measure type: multi-nozzle.
SCIP code
10449ebe-c9d7-4003-bc0d-323d29007172
|
|||
750259 | G 2" A (ISO 228-1) M union |
15 m³/h | multi-nozzle |
3D models
Tender text
Compact direct heat meter for heating solar systems. The metering module is supplied complete with:
- pair of temperature probes with immersion pockets;
- Y pockets for immersion probes;
- electronic integrator with LCD display.
Local reading via LCD display/centralised reading via BUS transmission. Connection: G 2" A (ISO 228-1) M, union. Maximum working pressure: 10 bar. Medium temperature range: 5–120 °C. Electric supply: 24 V (AC) / (DC). Power consumption: 1 W. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions. Nominal flow rate: 15 m³/h. Transmission: RS-485. Measure type: multi-nozzle.
SCIP code
90696bf0-a03e-4e7b-817a-758a427adb8f
|