Series 75025

CONTECA EASY SOLAR, Compact direct heat meter for heating solar systems.

Go to
750254.png
750254_dim~-~page-1.png
750254_app~-~page-1.png
750254.png
750254_dim~-~page-1.png
750254_app~-~page-1.png
Download high resolution

Product Description

Compact direct heat meter for heating solar systems.
The metering module is supplied complete with:
- pair of temperature probes with immersion pockets;
- Y pockets for immersion probes;
- electronic integrator with LCD display.
Local reading via LCD display/centralised reading via BUS transmission.

Technical data

Medium temperature range: 2–120 °C
Electric supply: 24 V AC
Running power consumption: 1 W
Protection class: IP 54
Probe/cable length: 1,9 m
Nominal pressure: PN 16
Accuracy class: 3
Maximum percentage of glycol: 50 %
Communication protocol: M-Bus on RS485

Certifications

CE
MI004

Drawings and specifications

Part number Connection Nominal flow rate Minimum flow rate (Qi)
Measure type
single nozzle
3D models
Tender text
Compact direct heat meter for heating solar systems. The metering module is supplied complete with: - pair of temperature probes with immersion pockets; - Y pockets for immersion probes; - electronic integrator with LCD display. Local reading via LCD display/centralised reading via BUS transmission. Connection: G 1/2" A (ISO 228-1) M. Medium temperature range: 2–120 °C. Electric supply: 24 V AC. Running power consumption: 1 W. Protection class: IP 54. Probe cable length: 1,9 m. Nominal pressure: PN 16. Accuracy class: 3. Maximum percentage of glycol: 50 %. Nominal flow rate: 1,5 m³/h. Minimum flow rate (Qi): 30 l/h. Communication protocol: M-Bus on RS485. Measure type: single nozzle.
SCIP code
02d7fc68-9da5-451b-af86-77cebdec727f
Measure type
single nozzle
2D drawings
Download
Download
3D models
Download
Download
Tender text
Compact direct heat meter for heating solar systems. The metering module is supplied complete with: - pair of temperature probes with immersion pockets; - Y pockets for immersion probes; - electronic integrator with LCD display. Local reading via LCD display/centralised reading via BUS transmission. Connection: G 3/4" A (ISO 228-1) M. Medium temperature range: 2–120 °C. Electric supply: 24 V AC. Running power consumption: 1 W. Protection class: IP 54. Probe cable length: 1,9 m. Nominal pressure: PN 16. Accuracy class: 3. Maximum percentage of glycol: 50 %. Nominal flow rate: 2,5 m³/h. Minimum flow rate (Qi): 50 l/h. Communication protocol: M-Bus on RS485. Measure type: single nozzle.
SCIP code
4632fb5e-3681-406a-aa22-ed23fad31ed5
Measure type
multi-nozzle
3D models
Tender text
Compact direct heat meter for heating solar systems. The metering module is supplied complete with: - pair of temperature probes with immersion pockets; - Y pockets for immersion probes; - electronic integrator with LCD display. Local reading via LCD display/centralised reading via BUS transmission. Connection: G 1" A (ISO 228-1) M. Medium temperature range: 2–120 °C. Electric supply: 24 V AC. Running power consumption: 1 W. Protection class: IP 54. Probe cable length: 1,9 m. Nominal pressure: PN 16. Accuracy class: 3. Maximum percentage of glycol: 50 %. Nominal flow rate: 3,5 m³/h. Minimum flow rate (Qi): 70 l/h. Communication protocol: M-Bus on RS485. Measure type: multi-nozzle.
SCIP code
edcfc008-d4d0-4758-8a48-b8a9a91a905a
Measure type
multi-nozzle
3D models
Tender text
Compact direct heat meter for heating solar systems. The metering module is supplied complete with: - pair of temperature probes with immersion pockets; - Y pockets for immersion probes; - electronic integrator with LCD display. Local reading via LCD display/centralised reading via BUS transmission. Connection: G 1 1/4" A (ISO 228-1) M. Medium temperature range: 2–120 °C. Electric supply: 24 V AC. Running power consumption: 1 W. Protection class: IP 54. Probe cable length: 1,9 m. Nominal pressure: PN 16. Accuracy class: 3. Maximum percentage of glycol: 50 %. Nominal flow rate: 6 m³/h. Minimum flow rate (Qi): 120 l/h. Communication protocol: M-Bus on RS485. Measure type: multi-nozzle.
SCIP code
1db3ff43-236b-4ffb-b95b-b4c979570b56
Measure type
multi-nozzle
2D drawings
Download
Download
3D models
Download
Download
Tender text
Compact direct heat meter for heating solar systems. The metering module is supplied complete with: - pair of temperature probes with immersion pockets; - Y pockets for immersion probes; - electronic integrator with LCD display. Local reading via LCD display/centralised reading via BUS transmission. Connection: G 1 1/2" A (ISO 228-1) M. Medium temperature range: 2–120 °C. Electric supply: 24 V AC. Running power consumption: 1 W. Protection class: IP 54. Probe cable length: 1,9 m. Nominal pressure: PN 16. Accuracy class: 3. Maximum percentage of glycol: 50 %. Nominal flow rate: 10 m³/h. Minimum flow rate (Qi): 200 l/h. Communication protocol: M-Bus on RS485. Measure type: multi-nozzle.
SCIP code
10449ebe-c9d7-4003-bc0d-323d29007172
Measure type
multi-nozzle
3D models
Tender text
Compact direct heat meter for heating solar systems. The metering module is supplied complete with: - pair of temperature probes with immersion pockets; - Y pockets for immersion probes; - electronic integrator with LCD display. Local reading via LCD display/centralised reading via BUS transmission. Connection: G 2" A (ISO 228-1) M. Medium temperature range: 2–120 °C. Electric supply: 24 V AC. Running power consumption: 1 W. Protection class: IP 54. Probe cable length: 1,9 m. Nominal pressure: PN 16. Accuracy class: 3. Maximum percentage of glycol: 50 %. Nominal flow rate: 15 m³/h. Minimum flow rate (Qi): 300 l/h. Communication protocol: M-Bus on RS485. Measure type: multi-nozzle.
SCIP code
90696bf0-a03e-4e7b-817a-758a427adb8f