Series 75025

CONTECA® EASY SOLAR, Compact direct heat meter for heating solar systems.

Go to
750254.png
750254_dim~-~page-1.png
750254_app~-~page-1.png
750254.png
750254_dim~-~page-1.png
750254_app~-~page-1.png
Download high resolution

Product Description

Compact direct heat meter for heating solar systems.
The metering module is supplied complete with:
- pair of temperature probes with immersion pockets;
- Y pockets for immersion probes;
- electronic integrator with LCD display.
Local reading via LCD display/centralised reading via BUS transmission.

Technical data

Medium temperature range: 5–120 °C
Electric supply: 24 V AC/DC
Running power consumption: 1 W
Protection class: IP 54
Probe/cable length: 1,9 m
Nominal pressure: PN 16
Accuracy class: 3
Maximum percentage of glycol: 50 %
Communication protocol: M-Bus on RS485

Certifications

CE
MI004

Drawings and specifications

Part number Connection Nominal flow rate Minimum flow rate (Qi)
Measure type
single nozzle
3D models
Tender text
CALEFFI, 750254, CONTECA® EASY SOLAR. Compact direct heat meter for heating solar systems. The metering module is supplied complete with: - pair of temperature probes with immersion pockets; - Y pockets for immersion probes; - electronic integrator with LCD display. Local reading via LCD display/centralised reading via BUS transmission. Connection: G 1/2" A (ISO 228-1) M. Medium temperature range: 5–120 °C. Electric supply: 24 V AC/DC. Running power consumption: 1 W. Protection class: IP 54. Probe/cable length: 1,9 m. Nominal pressure: PN 16. Accuracy class: 3. Maximum percentage of glycol: 50 %. Nominal flow rate: 1,5 m³/h. Minimum flow rate (Qi): 30 l/h. Communication protocol: M-Bus on RS485. Measure type: single nozzle.
SCIP code
02d7fc68-9da5-451b-af86-77cebdec727f
Measure type
single nozzle
2D drawings
Download
Download
3D models
Download
Download
Tender text
CALEFFI, 750255, CONTECA® EASY SOLAR. Compact direct heat meter for heating solar systems. The metering module is supplied complete with: - pair of temperature probes with immersion pockets; - Y pockets for immersion probes; - electronic integrator with LCD display. Local reading via LCD display/centralised reading via BUS transmission. Connection: G 3/4" A (ISO 228-1) M. Medium temperature range: 5–120 °C. Electric supply: 24 V AC/DC. Running power consumption: 1 W. Protection class: IP 54. Probe/cable length: 1,9 m. Nominal pressure: PN 16. Accuracy class: 3. Maximum percentage of glycol: 50 %. Nominal flow rate: 2,5 m³/h. Minimum flow rate (Qi): 50 l/h. Communication protocol: M-Bus on RS485. Measure type: single nozzle.
SCIP code
4632fb5e-3681-406a-aa22-ed23fad31ed5
Measure type
multi-nozzle
3D models
Tender text
CALEFFI, 750256, CONTECA® EASY SOLAR. Compact direct heat meter for heating solar systems. The metering module is supplied complete with: - pair of temperature probes with immersion pockets; - Y pockets for immersion probes; - electronic integrator with LCD display. Local reading via LCD display/centralised reading via BUS transmission. Connection: G 1" A (ISO 228-1) M. Medium temperature range: 5–120 °C. Electric supply: 24 V AC/DC. Running power consumption: 1 W. Protection class: IP 54. Probe/cable length: 1,9 m. Nominal pressure: PN 16. Accuracy class: 3. Maximum percentage of glycol: 50 %. Nominal flow rate: 3,5 m³/h. Minimum flow rate (Qi): 70 l/h. Communication protocol: M-Bus on RS485. Measure type: multi-nozzle.
SCIP code
edcfc008-d4d0-4758-8a48-b8a9a91a905a
Measure type
multi-nozzle
3D models
Tender text
CALEFFI, 750257, CONTECA® EASY SOLAR. Compact direct heat meter for heating solar systems. The metering module is supplied complete with: - pair of temperature probes with immersion pockets; - Y pockets for immersion probes; - electronic integrator with LCD display. Local reading via LCD display/centralised reading via BUS transmission. Connection: G 1 1/4" A (ISO 228-1) M. Medium temperature range: 5–120 °C. Electric supply: 24 V AC/DC. Running power consumption: 1 W. Protection class: IP 54. Probe/cable length: 1,9 m. Nominal pressure: PN 16. Accuracy class: 3. Maximum percentage of glycol: 50 %. Nominal flow rate: 6 m³/h. Minimum flow rate (Qi): 120 l/h. Communication protocol: M-Bus on RS485. Measure type: multi-nozzle.
SCIP code
1db3ff43-236b-4ffb-b95b-b4c979570b56
Measure type
multi-nozzle
2D drawings
Download
Download
3D models
Download
Download
Tender text
CALEFFI, 750258, CONTECA® EASY SOLAR. Compact direct heat meter for heating solar systems. The metering module is supplied complete with: - pair of temperature probes with immersion pockets; - Y pockets for immersion probes; - electronic integrator with LCD display. Local reading via LCD display/centralised reading via BUS transmission. Connection: G 1 1/2" A (ISO 228-1) M. Medium temperature range: 5–120 °C. Electric supply: 24 V AC/DC. Running power consumption: 1 W. Protection class: IP 54. Probe/cable length: 1,9 m. Nominal pressure: PN 16. Accuracy class: 3. Maximum percentage of glycol: 50 %. Nominal flow rate: 10 m³/h. Minimum flow rate (Qi): 200 l/h. Communication protocol: M-Bus on RS485. Measure type: multi-nozzle.
SCIP code
10449ebe-c9d7-4003-bc0d-323d29007172
Measure type
multi-nozzle
3D models
Tender text
CALEFFI, 750259, CONTECA® EASY SOLAR. Compact direct heat meter for heating solar systems. The metering module is supplied complete with: - pair of temperature probes with immersion pockets; - Y pockets for immersion probes; - electronic integrator with LCD display. Local reading via LCD display/centralised reading via BUS transmission. Connection: G 2" A (ISO 228-1) M. Medium temperature range: 5–120 °C. Electric supply: 24 V AC/DC. Running power consumption: 1 W. Protection class: IP 54. Probe/cable length: 1,9 m. Nominal pressure: PN 16. Accuracy class: 3. Maximum percentage of glycol: 50 %. Nominal flow rate: 15 m³/h. Minimum flow rate (Qi): 300 l/h. Communication protocol: M-Bus on RS485. Measure type: multi-nozzle.
SCIP code
90696bf0-a03e-4e7b-817a-758a427adb8f