CONTECA EASY SOLAR, Compact direct heat meter for heating solar systems.
Product Description
Compact direct heat meter for heating solar systems.
The metering module is supplied complete with:
- pair of temperature probes with immersion pockets;
- Y pockets for immersion probes;
- electronic integrator with LCD display.
Local reading via LCD display/centralised reading via BUS transmission.
Technical data
Medium temperature range:
2–120 °C
Electric supply:
24 V AC
Running power consumption:
1 W
Protection class:
IP 54
Probe/cable length:
1,9 m
Nominal pressure:
PN 16
Accuracy class:
3
Maximum percentage of glycol:
50 %
Communication protocol:
M-Bus on RS485
Certifications
Download
Drawings and specifications
Part number | Connection | Nominal flow rate | Minimum flow rate (Qi) |
---|---|---|---|
750254 | G 1/2" A (ISO 228-1) M |
1,5 m³/h | 30 l/h |
Measure type
single nozzle
|
|||
3D models
Tender text
Compact direct heat meter for heating solar systems. The metering module is supplied complete with:
- pair of temperature probes with immersion pockets;
- Y pockets for immersion probes;
- electronic integrator with LCD display.
Local reading via LCD display/centralised reading via BUS transmission. Connection: G 1/2" A (ISO 228-1) M. Medium temperature range: 2–120 °C. Electric supply: 24 V AC. Running power consumption: 1 W. Protection class: IP 54. Probe cable length: 1,9 m. Nominal pressure: PN 16. Accuracy class: 3. Maximum percentage of glycol: 50 %. Nominal flow rate: 1,5 m³/h. Minimum flow rate (Qi): 30 l/h. Communication protocol: M-Bus on RS485. Measure type: single nozzle.
SCIP code
02d7fc68-9da5-451b-af86-77cebdec727f
|
|||
750255 | G 3/4" A (ISO 228-1) M |
2,5 m³/h | 50 l/h |
Measure type
single nozzle
|
|||
2D drawings
3D models
Tender text
Compact direct heat meter for heating solar systems. The metering module is supplied complete with:
- pair of temperature probes with immersion pockets;
- Y pockets for immersion probes;
- electronic integrator with LCD display.
Local reading via LCD display/centralised reading via BUS transmission. Connection: G 3/4" A (ISO 228-1) M. Medium temperature range: 2–120 °C. Electric supply: 24 V AC. Running power consumption: 1 W. Protection class: IP 54. Probe cable length: 1,9 m. Nominal pressure: PN 16. Accuracy class: 3. Maximum percentage of glycol: 50 %. Nominal flow rate: 2,5 m³/h. Minimum flow rate (Qi): 50 l/h. Communication protocol: M-Bus on RS485. Measure type: single nozzle.
SCIP code
4632fb5e-3681-406a-aa22-ed23fad31ed5
|
|||
750256 | G 1" A (ISO 228-1) M |
3,5 m³/h | 70 l/h |
Measure type
multi-nozzle
|
|||
3D models
Tender text
Compact direct heat meter for heating solar systems. The metering module is supplied complete with:
- pair of temperature probes with immersion pockets;
- Y pockets for immersion probes;
- electronic integrator with LCD display.
Local reading via LCD display/centralised reading via BUS transmission. Connection: G 1" A (ISO 228-1) M. Medium temperature range: 2–120 °C. Electric supply: 24 V AC. Running power consumption: 1 W. Protection class: IP 54. Probe cable length: 1,9 m. Nominal pressure: PN 16. Accuracy class: 3. Maximum percentage of glycol: 50 %. Nominal flow rate: 3,5 m³/h. Minimum flow rate (Qi): 70 l/h. Communication protocol: M-Bus on RS485. Measure type: multi-nozzle.
SCIP code
edcfc008-d4d0-4758-8a48-b8a9a91a905a
|
|||
750257 | G 1 1/4" A (ISO 228-1) M |
6 m³/h | 120 l/h |
Measure type
multi-nozzle
|
|||
3D models
Tender text
Compact direct heat meter for heating solar systems. The metering module is supplied complete with:
- pair of temperature probes with immersion pockets;
- Y pockets for immersion probes;
- electronic integrator with LCD display.
Local reading via LCD display/centralised reading via BUS transmission. Connection: G 1 1/4" A (ISO 228-1) M. Medium temperature range: 2–120 °C. Electric supply: 24 V AC. Running power consumption: 1 W. Protection class: IP 54. Probe cable length: 1,9 m. Nominal pressure: PN 16. Accuracy class: 3. Maximum percentage of glycol: 50 %. Nominal flow rate: 6 m³/h. Minimum flow rate (Qi): 120 l/h. Communication protocol: M-Bus on RS485. Measure type: multi-nozzle.
SCIP code
1db3ff43-236b-4ffb-b95b-b4c979570b56
|
|||
750258 | G 1 1/2" A (ISO 228-1) M |
10 m³/h | 200 l/h |
Measure type
multi-nozzle
|
|||
2D drawings
3D models
Tender text
Compact direct heat meter for heating solar systems. The metering module is supplied complete with:
- pair of temperature probes with immersion pockets;
- Y pockets for immersion probes;
- electronic integrator with LCD display.
Local reading via LCD display/centralised reading via BUS transmission. Connection: G 1 1/2" A (ISO 228-1) M. Medium temperature range: 2–120 °C. Electric supply: 24 V AC. Running power consumption: 1 W. Protection class: IP 54. Probe cable length: 1,9 m. Nominal pressure: PN 16. Accuracy class: 3. Maximum percentage of glycol: 50 %. Nominal flow rate: 10 m³/h. Minimum flow rate (Qi): 200 l/h. Communication protocol: M-Bus on RS485. Measure type: multi-nozzle.
SCIP code
10449ebe-c9d7-4003-bc0d-323d29007172
|
|||
750259 | G 2" A (ISO 228-1) M |
15 m³/h | 300 l/h |
Measure type
multi-nozzle
|
|||
3D models
Tender text
Compact direct heat meter for heating solar systems. The metering module is supplied complete with:
- pair of temperature probes with immersion pockets;
- Y pockets for immersion probes;
- electronic integrator with LCD display.
Local reading via LCD display/centralised reading via BUS transmission. Connection: G 2" A (ISO 228-1) M. Medium temperature range: 2–120 °C. Electric supply: 24 V AC. Running power consumption: 1 W. Protection class: IP 54. Probe cable length: 1,9 m. Nominal pressure: PN 16. Accuracy class: 3. Maximum percentage of glycol: 50 %. Nominal flow rate: 15 m³/h. Minimum flow rate (Qi): 300 l/h. Communication protocol: M-Bus on RS485. Measure type: multi-nozzle.
SCIP code
90696bf0-a03e-4e7b-817a-758a427adb8f
|