Series 116

Thermostatic regulator for domestic hot water recirculation circuits. Designed for automatic or controlled thermal disinfection function.

Go to
116140.png
116140_sez2~-~page-1.png
116140_dim~-~page-1.png
116140.png
116140_sez2~-~page-1.png
116140_dim~-~page-1.png
Download high resolution

Product Description

Thermostatic regulator for domestic hot water recirculation circuits. Designed for automatic or controlled thermal disinfection function.
With pocket for temperature gauge.

Technical data

Maximum working pressure: 16 bar
Material: dezincification resistant brass DR "low lead"
Low Lead

Certifications

DVGW DIN CERT
WRAS
HY-CERT
ACS
PZH

Drawings and specifications

Part number Connection Adjustment temperature range DN
2D drawings
Download
Download
3D models
Download
Download
Tender text
Thermostatic regulator for domestic hot water recirculation circuits. Designed for automatic or controlled thermal disinfection function. With pocket for temperature gauge. Connection: Rp 1/2" (EN 10226-1) F. Maximum working pressure: 16 bar. Adjustment temperature range: 35–60 °C. DN: DN 15 (body). Material: dezincification resistant brass DR "low lead".
SCIP code
CODICE IN FASE DI ANALISI
2D drawings
Download
Download
3D models
Download
Download
Tender text
Thermostatic regulator for domestic hot water recirculation circuits. Designed for automatic or controlled thermal disinfection function. With pocket for temperature gauge. Connection: Rp 3/4" (EN 10226-1) F. Maximum working pressure: 16 bar. Adjustment temperature range: 35–60 °C. DN: DN 20 (body). Material: dezincification resistant brass DR "low lead".
SCIP code
fdb7ddd8-bb42-4ac4-b893-6612cca17cc7
2D drawings
Download
Download
3D models
Download
Download
Tender text
Thermostatic regulator for domestic hot water recirculation circuits. Designed for automatic or controlled thermal disinfection function. With pocket for temperature gauge. Connection: Rp 1" (EN 10226-1) F. Maximum working pressure: 16 bar. Adjustment temperature range: 35–65 °C. DN: DN 25 (body). Material: dezincification resistant brass DR "low lead".
SCIP code
CODICE IN FASE DI ANALISI
2D drawings
Download
Download
3D models
Download
Download
Tender text
Thermostatic regulator for domestic hot water recirculation circuits. Designed for automatic or controlled thermal disinfection function. With pocket for temperature gauge. Connection: Rp 1 1/4" (EN 10226-1) F. Maximum working pressure: 16 bar. Adjustment temperature range: 35–65 °C. DN: DN 32 (body). Material: dezincification resistant brass DR "low lead".
SCIP code
CODICE IN FASE DI ANALISI

Applications

Pipe Sizer Caleffi
Pipe Sizer Caleffi

This application allows for sizing and making calculations for pipes and conduits carrying water or air, respectively for hydraulic or aeraulic plants.