Control unit for domestic hot water temperature at the point of distribution, complete with recirculation connection.
Product Description
Control unit for domestic hot water temperature at the point of distribution, complete with recirculation connection.
Complete with:
- thermostatic mixing valve with thermal shut-off function;
- tee for cold water connection complete with check valves
- kit for recirculation connection complete with check valves;
- shut-off valves;
- temperature gauge with pocket on the mixed water outlet.
Mixing valve certified to EN 1111 and EN 1287.
Technical data
Maximum working pressure:
10 bar
Primary inlet working temperature range:
2–90 °C
Download
Drawings and specifications
Part number | IN connection | OUT connection | Adjustment temperature range |
---|---|---|---|
520155 | G 3/4" A (ISO 228-1) M |
G 3/4" (ISO 228-1) F |
35–65 °C |
DN
DN 20 (body)
|
Kv
1,7 m³/h
|
||
3D models
Tender text
Control unit for domestic hot water temperature at the point of distribution, complete with recirculation connection. Complete with:
- thermostatic mixing valve with thermal shut-off function;
- tee for cold water connection complete with check valves
- kit for recirculation connection complete with check valves;
- shut-off valves;
- temperature gauge with pocket on the mixed water outlet.
Mixing valve certified to EN 1111 and EN 1287. IN connection: G 3/4" A (ISO 228-1) M. OUT connection: G 3/4" (ISO 228-1) F. Maximum working pressure: 10 bar. Adjustment temperature range: 35–65 °C. Primary inlet working temperature range: 2–90 °C. DN: DN 20 (body). Kv: 1,7 m³/h.
SCIP code
fb115163-b209-4f89-a162-ab77a392d314
|