Series 121

AUTOFLOW, Combination of automatic flow rate regulator and ball valve. AUTOFLOW® high-performance polymer cartridge.

Go to
121161.png
121141_dim~-~page-1.png
121141_sez~-~page-1.png
121161.png
121141_dim~-~page-1.png
121141_sez~-~page-1.png
Download high resolution

Product Description

Combination of automatic flow rate regulator and ball valve. AUTOFLOW® high-performance polymer cartridge.
Accuracy: ± 5 %. Flow rates: 0,085–11,0 m3/h.
Designed for pressure point and drain valve connection.
PATENT

Technical data

Maximum working pressure: 25 bar
Medium temperature range: 0–110 °C
Maximum percentage of glycol: 50 %
Medium: water, glycol solutions
Range △p: 15–200 kPa
Material: dezincification resistant brass DR

Drawings and specifications

Part number Connection Kv
3D models
Tender text
Combination of automatic flow rate regulator and ball valve. AUTOFLOW® high-performance polymer cartridge. Accuracy: ± 5 %. Flow rates: 0,085–11,0 m3/h. Designed for pressure point and drain valve connection. Connection: G 1/2" (ISO 228-1) F. Maximum working pressure: 25 bar. Medium temperature range: 0–110 °C. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions. Range △p: 15–200 kPa. Kv: 6,90 m³/h. Material: dezincification resistant brass DR.
3D models
Tender text
Combination of automatic flow rate regulator and ball valve. AUTOFLOW® high-performance polymer cartridge. Accuracy: ± 5 %. Flow rates: 0,085–11,0 m3/h. Designed for pressure point and drain valve connection. Connection: G 3/4" (ISO 228-1) F. Maximum working pressure: 25 bar. Medium temperature range: 0–110 °C. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions. Range △p: 15–200 kPa. Kv: 7,73 m³/h. Material: dezincification resistant brass DR.
3D models
Tender text
Combination of automatic flow rate regulator and ball valve. AUTOFLOW® high-performance polymer cartridge. Accuracy: ± 5 %. Flow rates: 0,085–11,0 m3/h. Designed for pressure point and drain valve connection. Connection: G 1" (ISO 228-1) F. Maximum working pressure: 25 bar. Medium temperature range: 0–110 °C. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions. Range △p: 15–200 kPa. Kv: 18,00 m³/h. Material: dezincification resistant brass DR.
3D models
Tender text
Combination of automatic flow rate regulator and ball valve. AUTOFLOW® high-performance polymer cartridge. Accuracy: ± 5 %. Flow rates: 0,085–11,0 m3/h. Designed for pressure point and drain valve connection. Connection: G 1 1/4" (ISO 228-1) F. Maximum working pressure: 25 bar. Medium temperature range: 0–110 °C. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions. Range △p: 15–200 kPa. Kv: 18,50 m³/h. Material: dezincification resistant brass DR.
3D models
Tender text
Combination of automatic flow rate regulator and ball valve. AUTOFLOW® high-performance polymer cartridge. Accuracy: ± 5 %. Flow rates: 0,085–11,0 m3/h. Designed for pressure point and drain valve connection. Connection: G 1 1/2" (ISO 228-1) F. Maximum working pressure: 25 bar. Medium temperature range: 0–110 °C. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions. Range △p: 15–200 kPa. Kv: 47,24 m³/h. Material: dezincification resistant brass DR.
3D models
Tender text
Combination of automatic flow rate regulator and ball valve. AUTOFLOW® high-performance polymer cartridge. Accuracy: ± 5 %. Flow rates: 0,085–11,0 m3/h. Designed for pressure point and drain valve connection. Connection: G 2" (ISO 228-1) F. Maximum working pressure: 25 bar. Medium temperature range: 0–110 °C. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions. Range △p: 15–200 kPa. Kv: 48,89 m³/h. Material: dezincification resistant brass DR.

Applications

Pipe Sizer Caleffi
Pipe Sizer Caleffi

This application allows for sizing and making calculations for pipes and conduits carrying water or air, respectively for hydraulic or aeraulic plants.