Series 6452

Two-way motorised ball zone valve for heating and cooling systems.

Go to
645242.png
645242_dim~-~page-1.png
645242_sez~-~page-1.png
645242.png
645242_dim~-~page-1.png
645242_sez~-~page-1.png
Download high resolution

Product Description

Two-way motorised ball zone valve for heating and cooling systems.
With manual opening lever.
With insulation.
With auxiliary microswitch.

Technical data

Maximum working pressure: 10 bar
Medium temperature range: -10–110 °C
Ambient temperature range: -10–55 °C
Power consumption: 6 VA
Protection class: IP 65
Supply cable length: 0,8 m
Auxiliary microswitch contact rating (230 V): 6 (2) A
△p max.: 10 bar
Operating time: 50 s
Operating time - Note: 90° rotation

Certifications

CE
ENEC13

Drawings and specifications

Part number Connection Electric supply Kv
3D models
Tender text
Two-way motorised ball zone valve for heating and cooling systems. With auxiliary microswitch. With manual opening lever. Connection: G 1/2" A (ISO 228-1) M. Maximum working pressure: 10 bar. Medium temperature range: -10–110 °C. Ambient temperature range: -10–55 °C. Electric supply: 230 V (AC). Power consumption: 6 VA. Protection class: IP 65. Supply cable length: 0,8 m. Auxiliary microswitch contact rating (230 V): 6 (2) A. △p max.: 10 bar. Kv: 17,00 m³/h. Operating time: 50 s (90° rotation).
SCIP code
ca959b44-b7d8-4e08-9eed-e8b1bdeae1ea
3D models
Tender text
Two-way motorised ball zone valve for heating and cooling systems. With auxiliary microswitch. With manual opening lever. Connection: G 3/4" A (ISO 228-1) M. Maximum working pressure: 10 bar. Medium temperature range: -10–110 °C. Ambient temperature range: -10–55 °C. Electric supply: 230 V (AC). Power consumption: 6 VA. Protection class: IP 65. Supply cable length: 0,8 m. Auxiliary microswitch contact rating (230 V): 6 (2) A. △p max.: 10 bar. Kv: 17,27 m³/h. Operating time: 50 s (90° rotation).
SCIP code
d61f2474-bca5-40ad-9ee0-a228173af647
3D models
Tender text
Two-way motorised ball zone valve for heating and cooling systems. With auxiliary microswitch. With manual opening lever. Connection: G 1" A (ISO 228-1) M. Maximum working pressure: 10 bar. Medium temperature range: -10–110 °C. Ambient temperature range: -10–55 °C. Electric supply: 230 V (AC). Power consumption: 6 VA. Protection class: IP 65. Supply cable length: 0,8 m. Auxiliary microswitch contact rating (230 V): 6 (2) A. △p max.: 10 bar. Kv: 36,58 m³/h. Operating time: 50 s (90° rotation).
SCIP code
0a23ed13-c9e9-43ee-829f-63fa731d9124
2D drawings
Download
Download
3D models
Download
Download
Tender text
Two-way motorised ball zone valve for heating and cooling systems. With auxiliary microswitch. With manual opening lever. Connection: G 1 1/4" A (ISO 228-1) M. Maximum working pressure: 10 bar. Medium temperature range: -10–110 °C. Ambient temperature range: -10–55 °C. Electric supply: 230 V (AC). Power consumption: 6 VA. Protection class: IP 65. Supply cable length: 0,8 m. Auxiliary microswitch contact rating (230 V): 6 (2) A. △p max.: 10 bar. Kv: 39,50 m³/h. Operating time: 50 s (90° rotation).
SCIP code
db931e29-0219-45fa-9da4-7021fb982e66
3D models
Tender text
Two-way motorised ball zone valve for heating and cooling systems. With auxiliary microswitch. With manual opening lever. Connection: G 1/2" A (ISO 228-1) M. Maximum working pressure: 10 bar. Medium temperature range: -10–110 °C. Ambient temperature range: -10–55 °C. Electric supply: 24 V (AC). Power consumption: 6 VA. Protection class: IP 65. Supply cable length: 0,8 m. Auxiliary microswitch contact rating (230 V): 6 (2) A. △p max.: 10 bar. Kv: 17,00 m³/h. Operating time: 50 s (90° rotation).
SCIP code
037a7711-f379-4c54-979d-9e7c07a7d769
3D models
Tender text
Two-way motorised ball zone valve for heating and cooling systems. With auxiliary microswitch. With manual opening lever. Connection: G 3/4" A (ISO 228-1) M. Maximum working pressure: 10 bar. Medium temperature range: -10–110 °C. Ambient temperature range: -10–55 °C. Electric supply: 24 V (AC). Power consumption: 6 VA. Protection class: IP 65. Supply cable length: 0,8 m. Auxiliary microswitch contact rating (230 V): 6 (2) A. △p max.: 10 bar. Kv: 17,27 m³/h. Operating time: 50 s (90° rotation).
SCIP code
92c992d6-4146-476a-8b54-a02961658839
3D models
Tender text
Two-way motorised ball zone valve for heating and cooling systems. With auxiliary microswitch. With manual opening lever. Connection: G 1" A (ISO 228-1) M. Maximum working pressure: 10 bar. Medium temperature range: -10–110 °C. Ambient temperature range: -10–55 °C. Electric supply: 24 V (AC). Power consumption: 6 VA. Protection class: IP 65. Supply cable length: 0,8 m. Auxiliary microswitch contact rating (230 V): 6 (2) A. △p max.: 10 bar. Kv: 36,58 m³/h. Operating time: 50 s (90° rotation).
SCIP code
a9eeb3ab-7050-43ef-a8cf-5cea1c64032c
3D models
Tender text
Two-way motorised ball zone valve for heating and cooling systems. With auxiliary microswitch. With manual opening lever. Connection: G 1 1/4" A (ISO 228-1) M. Maximum working pressure: 10 bar. Medium temperature range: -10–110 °C. Ambient temperature range: -10–55 °C. Electric supply: 24 V (AC). Power consumption: 6 VA. Protection class: IP 65. Supply cable length: 0,8 m. Auxiliary microswitch contact rating (230 V): 6 (2) A. △p max.: 10 bar. Kv: 39,50 m³/h. Operating time: 50 s (90° rotation).
SCIP code
0480d701-e313-4eca-9538-999410e7aa86

Applications

Pipe Sizer Caleffi
Pipe Sizer Caleffi

This application allows for sizing and making calculations for pipes and conduits carrying water or air, respectively for hydraulic or aeraulic plants.