Balancing valve with flow meter and direct reading of flow rate.
Product Description
Balancing valve with flow meter and direct reading of flow rate.
Graduated scale flow meter with magnetic movement flow rate indicator.
Brass flow meter.
To be coupled with flat counterflanges EN 1092-1.
 
PATENT
Technical data
                        Maximum working pressure:
                        10 bar
                      
                                          
                        Medium temperature range:
                        -10–110 °C
                      
                                          
                        Maximum percentage of glycol:
                        50 %
                      
                                          
                        Medium:
                        water, glycol solutions
                      
                                          
                        Material:
                        cast iron 
                      
                                      Download
Drawings and specifications
| Part number | Connection | Flow rate regulation range | |
|---|---|---|---|
| 132060 | DN 65 (EN 1092-1) PN 16 | 6–24 m³/h | |
| 3D models Tender text 
                      CALEFFI, 132060.
Balancing valve with flow meter and direct reading of flow rate.
 Graduated scale flow meter with magnetic movement flow rate indicator.
Brass flow meter.
To be coupled with flat counterflanges EN 1092-1.
  Connection: DN 65 (EN 1092-1) PN 16. Maximum working pressure: 10 bar. Medium temperature range: -10–110 °C. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions. Flow rate regulation range: 6–24 m³/h. Material: cast iron. 
                     SCIP code 
                          cb753e9f-0218-47fb-85d5-a048c3c408ee
                         | |||
| 132080 | DN 80 (EN 1092-1) PN 16 | 8–32 m³/h | |
| 3D models Tender text 
                      CALEFFI, 132080.
Balancing valve with flow meter and direct reading of flow rate.
 Graduated scale flow meter with magnetic movement flow rate indicator.
Brass flow meter.
To be coupled with flat counterflanges EN 1092-1.
  Connection: DN 80 (EN 1092-1) PN 16. Maximum working pressure: 10 bar. Medium temperature range: -10–110 °C. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions. Flow rate regulation range: 8–32 m³/h. Material: cast iron. 
                     SCIP code 
                          80cd2dc8-7d5f-4126-b3ba-28c08727e9d3
                         | |||
| 132100 | DN 100 (EN 1092-1) PN 16 | 12–48 m³/h | |
| 3D models Tender text 
                      CALEFFI, 132100.
Balancing valve with flow meter and direct reading of flow rate.
 Graduated scale flow meter with magnetic movement flow rate indicator.
Brass flow meter.
To be coupled with flat counterflanges EN 1092-1.
  Connection: DN 100 (EN 1092-1) PN 16. Maximum working pressure: 10 bar. Medium temperature range: -10–110 °C. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions. Flow rate regulation range: 12–48 m³/h. 
                     SCIP code 
                          467b3baa-3b40-47dc-9fa8-a36d00f9e95e
                         | |||
 
   
   
 
 
 
           
        