Series 838

Solenoid valve for gas, normally closed.

Go to
838004.png
Download high resolution

Product Description

Solenoid valve for gas, normally closed.
Class A - Group 2.

Technical data

Maximum working pressure: 360 mbar
Protection class: IP 65

Certifications

CE

Drawings and specifications

Part number Connection Note Electric supply
3D models
Download
Download
Tender text
Solenoid valve for gas, normally closed. Class A - Group 2. Connection: Rp 1/2" (EN 10226-1) F. Maximum working pressure: 360 mbar. Electric supply: 230 V (AC). Protection class: IP 65.
SCIP code
5a64e3ec-aac5-49b5-870a-8722ed1e8bdd
3D models
Download
Download
Tender text
Solenoid valve for gas, normally closed. Class A - Group 2. Connection: Rp 3/4" (EN 10226-1) F. Maximum working pressure: 360 mbar. Electric supply: 230 V (AC). Protection class: IP 65.
SCIP code
5a64e3ec-aac5-49b5-870a-8722ed1e8bdd
3D models
Download
Download
Tender text
Solenoid valve for gas, normally closed. Class A - Group 2. Connection: Rp 1" (EN 10226-1) F. Maximum working pressure: 360 mbar. Electric supply: 230 V (AC). Protection class: IP 65.
SCIP code
5a64e3ec-aac5-49b5-870a-8722ed1e8bdd
3D models
Download
Download
Tender text
Solenoid valve for gas, normally closed. Class A - Group 2. Connection: Rp 1 1/4" (EN 10226-1) F. Maximum working pressure: 360 mbar. Electric supply: 230 V (AC). Protection class: IP 65.
SCIP code
5a64e3ec-aac5-49b5-870a-8722ed1e8bdd
3D models
Download
Download
Tender text
Solenoid valve for gas, normally closed. Class A - Group 2. Connection: Rp 1 1/2" (EN 10226-1) F. Maximum working pressure: 360 mbar. Electric supply: 230 V (AC). Protection class: IP 65.
SCIP code
5a64e3ec-aac5-49b5-870a-8722ed1e8bdd
3D models
Download
Download
Tender text
Solenoid valve for gas, normally closed. Class A - Group 2. Connection: Rp 2" (EN 10226-1) F. Maximum working pressure: 360 mbar. Electric supply: 230 V (AC). Protection class: IP 65.
SCIP code
5a64e3ec-aac5-49b5-870a-8722ed1e8bdd
3D models
Download
Download
Tender text
Solenoid valve for gas, normally closed. Class A - Group 2. Connection: Rp 1/2" (EN 10226-1) F. Maximum working pressure: 360 mbar. Electric supply: 24 V (AC). Protection class: IP 65.
SCIP code
5a64e3ec-aac5-49b5-870a-8722ed1e8bdd
3D models
Download
Download
Tender text
Solenoid valve for gas, normally closed. Class A - Group 2. Connection: Rp 3/4" (EN 10226-1) F. Maximum working pressure: 360 mbar. Electric supply: 24 V (AC). Protection class: IP 65.
SCIP code
5a64e3ec-aac5-49b5-870a-8722ed1e8bdd
3D models
Download
Download
Tender text
Solenoid valve for gas, normally closed. Class A - Group 2. Connection: Rp 1" (EN 10226-1) F. Maximum working pressure: 360 mbar. Electric supply: 24 V (AC). Protection class: IP 65.
SCIP code
5a64e3ec-aac5-49b5-870a-8722ed1e8bdd
3D models
Download
Download
Tender text
Solenoid valve for gas, normally closed. Class A - Group 2. Connection: Rp 1 1/4" (EN 10226-1) F. Maximum working pressure: 360 mbar. Electric supply: 24 V (AC). Protection class: IP 65.
SCIP code
5a64e3ec-aac5-49b5-870a-8722ed1e8bdd
3D models
Download
Download
Tender text
Solenoid valve for gas, normally closed. Class A - Group 2. Connection: Rp 1 1/2" (EN 10226-1) F. Maximum working pressure: 360 mbar. Electric supply: 24 V (AC). Protection class: IP 65.
SCIP code
5a64e3ec-aac5-49b5-870a-8722ed1e8bdd
3D models
Download
Download
Tender text
Solenoid valve for gas, normally closed. Class A - Group 2. Connection: Rp 2" (EN 10226-1) F. Maximum working pressure: 360 mbar. Electric supply: 24 V (AC). Protection class: IP 65.
SCIP code
5a64e3ec-aac5-49b5-870a-8722ed1e8bdd

Applications

Pipe Sizer Caleffi
Pipe Sizer Caleffi

This application allows for sizing and making calculations for pipes and conduits carrying water or air, respectively for hydraulic or aeraulic plants.