Series 167

Motorised regulating unit DN 32, for heating and cooling systems.

Go to
167662he4.png
167662he4.png
Download high resolution

Product Description

Motorised regulating unit DN 32, for heating and cooling systems.
Right - left convertible.
Available with three-point control signal actuator (note A) or 0(2)–10V control signal and 0–10V feedback signal (note B).
Regulation with three-way sector valve.
With insulation.

Technical data

Maximum working pressure: 10 bar
Medium temperature range: 5–100 °C
Outlet centre distance: 125 mm
Type of pump: Para 25-9

Note

Note A: three-point control signal actuator.
Operating time: 150 s.
Can be combined with regulators code 161010 and 1520 series.

Note B: 0(2)–10 V control signal actuator.
Feedback signal: 0–10 V.
Operating time: 75 s.
Can be combined with regulator code 161010 (for actuator electic supply use 230V / 24V transformer).

Certifications

CE

Drawings and specifications

Part number System side connection Boiler side connection Note
Electric supply
230 V AC
Flow rate with available head 4 m w.g.
2,2 m³/h
2D drawings
Download
Download
3D models
Download
Download
Tender text
Motorised regulating unit DN 32, for heating and cooling systems. With insulation. With auxiliary microswitch. Right - left convertible. Available with three-point control signal actuator (note A) or 0(2)–10V control signal and 0–10V feedback signal (note B). Regulation with three-way sector valve. System side connection: G 1 1/2" A (ISO 228-1) M. Boiler side connection: G 1 1/4" (ISO 228-1) F. Maximum working pressure: 10 bar. Medium temperature range: 5–100 °C. Electric supply: 230 V AC. Outlet centre distance: 125 mm. Flow rate with available head 4 m w.g.: 2,2 m³/h. Type of pump: Para 25-9.
SCIP code
375fe02e-d029-4738-a96c-7828eac8c7d7
Electric supply
24 V AC
Flow rate with available head 4 m w.g.
2,2 m³/h
2D drawings
Download
Download
3D models
Download
Download
Tender text
Motorised regulating unit DN 32, for heating and cooling systems. With insulation. With auxiliary microswitch. Right - left convertible. Available with three-point control signal actuator (note A) or 0(2)–10V control signal and 0–10V feedback signal (note B). Regulation with three-way sector valve. System side connection: G 1 1/2" A (ISO 228-1) M, end outlet. Boiler side connection: G 1 1/4" (ISO 228-1) F. Maximum working pressure: 10 bar. Medium temperature range: 5–100 °C. Electric supply: 24 V AC. Outlet centre distance: 125 mm. Flow rate with available head 4 m w.g.: 2,2 m³/h. Type of pump: Para 25-9.
SCIP code
e14c9fcb-10ce-4ca0-99e5-c101423be3e1

Applications

Pipe Sizer Caleffi
Pipe Sizer Caleffi

This application allows for sizing and making calculations for pipes and conduits carrying water or air, respectively for hydraulic or aeraulic plants.