Series 172

Low temperature manifold mixing station (with 3-speed pump)

Go to
1725C1A.png
1725C1A.png
Download high resolution

Product Description

Low temperature manifold mixing station (with 3-speed pump)
Supply manifold complete with:

  • Flow meters
  • Adjustable balancing valves

Return manifold complete with:

  • Shut-off valves that can be replaced by thermo-electric actuators

Includes Grundfos UPMS 15-58U pump

Models with "IN" suffix are built inverted with tubing connections going upward

Technical data

Maximum operating pressure: 150 psi
Adjustment temperature range: 80 – 130 °F
Maximum inlet temperature: 195 °F
Outlet center distance: 2 "

Drawings and specifications

Part number Connection Outlet Connection Type of pump
3D models
Tender text
CALEFFI, 1725C1A. Low temperature manifold mixing station (with 3-speed pump) Supply manifold complete with: Flow meters Adjustable balancing valves Return manifold complete with: Shut-off valves that can be replaced by thermo-electric actuators Includes Grundfos UPMS 15-58U pump Models with "IN" suffix are built inverted with tubing connections going upward connection: 3/4" PRS. Outlet Connection: 3/4" M (non usare), 3 outlets. Maximum operating pressure: 150 psi. Adjustment temperature range: 80 – 130 °F. Maximum inlet temperature: 195 °F. Outlet center distance: 2 ". Type of pump: UPS 15-58.
3D models
Tender text
CALEFFI, 1725C1A IN. Low temperature manifold mixing station (with 3-speed pump) Supply manifold complete with: Flow meters Adjustable balancing valves Return manifold complete with: Shut-off valves that can be replaced by thermo-electric actuators Includes Grundfos UPMS 15-58U pump Models with "IN" suffix are built inverted with tubing connections going upward connection: 3/4" PRS. Outlet Connection: 3/4" M (non usare), 3 outlets. Maximum operating pressure: 150 psi. Adjustment temperature range: 80 – 130 °F. Maximum inlet temperature: 195 °F. Outlet center distance: 2 ". Type of pump: UPS 15-58.
3D models
Tender text
CALEFFI, 1725D1A. Low temperature manifold mixing station (with 3-speed pump) Supply manifold complete with: Flow meters Adjustable balancing valves Return manifold complete with: Shut-off valves that can be replaced by thermo-electric actuators Includes Grundfos UPMS 15-58U pump Models with "IN" suffix are built inverted with tubing connections going upward connection: 3/4" PRS. Outlet Connection: 3/4" M (non usare), 4 outlets. Maximum operating pressure: 150 psi. Adjustment temperature range: 80 – 130 °F. Maximum inlet temperature: 195 °F. Outlet center distance: 2 ". Type of pump: UPS 15-58.
3D models
Tender text
CALEFFI, 1725D1A IN. Low temperature manifold mixing station (with 3-speed pump) Supply manifold complete with: Flow meters Adjustable balancing valves Return manifold complete with: Shut-off valves that can be replaced by thermo-electric actuators Includes Grundfos UPMS 15-58U pump Models with "IN" suffix are built inverted with tubing connections going upward connection: 3/4" PRS. Outlet Connection: 3/4" M (non usare), 4 outlets. Maximum operating pressure: 150 psi. Adjustment temperature range: 80 – 130 °F. Maximum inlet temperature: 195 °F. Outlet center distance: 2 ". Type of pump: UPS 15-58.
3D models
Tender text
CALEFFI, 1725E1A. Low temperature manifold mixing station (with 3-speed pump) Supply manifold complete with: Flow meters Adjustable balancing valves Return manifold complete with: Shut-off valves that can be replaced by thermo-electric actuators Includes Grundfos UPMS 15-58U pump Models with "IN" suffix are built inverted with tubing connections going upward connection: 3/4" PRS. Outlet Connection: 3/4" M (non usare), 5 outlets. Maximum operating pressure: 150 psi. Adjustment temperature range: 80 – 130 °F. Maximum inlet temperature: 195 °F. Outlet center distance: 2 ". Type of pump: UPS 15-58.
3D models
Tender text
CALEFFI, 1725E1A IN. Low temperature manifold mixing station (with 3-speed pump) Supply manifold complete with: Flow meters Adjustable balancing valves Return manifold complete with: Shut-off valves that can be replaced by thermo-electric actuators Includes Grundfos UPMS 15-58U pump Models with "IN" suffix are built inverted with tubing connections going upward connection: 3/4" PRS. Outlet Connection: 3/4" M (non usare), 5 outlets. Maximum operating pressure: 150 psi. Adjustment temperature range: 80 – 130 °F. Maximum inlet temperature: 195 °F. Outlet center distance: 2 ". Type of pump: UPS 15-58.
3D models
Tender text
CALEFFI, 1725F1A. Low temperature manifold mixing station (with 3-speed pump) Supply manifold complete with: Flow meters Adjustable balancing valves Return manifold complete with: Shut-off valves that can be replaced by thermo-electric actuators Includes Grundfos UPMS 15-58U pump Models with "IN" suffix are built inverted with tubing connections going upward connection: 3/4" PRS. Outlet Connection: 3/4" M (non usare), 6 outlets. Maximum operating pressure: 150 psi. Adjustment temperature range: 80 – 130 °F. Maximum inlet temperature: 195 °F. Outlet center distance: 2 ". Type of pump: UPS 15-58.
3D models
Tender text
CALEFFI, 1725F1A IN. Low temperature manifold mixing station (with 3-speed pump) Supply manifold complete with: Flow meters Adjustable balancing valves Return manifold complete with: Shut-off valves that can be replaced by thermo-electric actuators Includes Grundfos UPMS 15-58U pump Models with "IN" suffix are built inverted with tubing connections going upward connection: 3/4" PRS. Outlet Connection: 3/4" M (non usare), 6 outlets. Maximum operating pressure: 150 psi. Adjustment temperature range: 80 – 130 °F. Maximum inlet temperature: 195 °F. Outlet center distance: 2 ". Type of pump: UPS 15-58.
3D models
Tender text
CALEFFI, 1725G1A. Low temperature manifold mixing station (with 3-speed pump) Supply manifold complete with: Flow meters Adjustable balancing valves Return manifold complete with: Shut-off valves that can be replaced by thermo-electric actuators Includes Grundfos UPMS 15-58U pump Models with "IN" suffix are built inverted with tubing connections going upward connection: 3/4" PRS. Outlet Connection: 3/4" M (non usare), 7 outlets. Maximum operating pressure: 150 psi. Adjustment temperature range: 80 – 130 °F. Maximum inlet temperature: 195 °F. Outlet center distance: 2 ". Type of pump: UPS 15-58.
3D models
Tender text
CALEFFI, 1725G1A IN. Low temperature manifold mixing station (with 3-speed pump) Supply manifold complete with: Flow meters Adjustable balancing valves Return manifold complete with: Shut-off valves that can be replaced by thermo-electric actuators Includes Grundfos UPMS 15-58U pump Models with "IN" suffix are built inverted with tubing connections going upward connection: 3/4" PRS. Outlet Connection: 3/4" M (non usare), 7 outlets. Maximum operating pressure: 150 psi. Adjustment temperature range: 80 – 130 °F. Maximum inlet temperature: 195 °F. Outlet center distance: 2 ". Type of pump: UPS 15-58.
3D models
Tender text
CALEFFI, 1725H1A. Low temperature manifold mixing station (with 3-speed pump) Supply manifold complete with: Flow meters Adjustable balancing valves Return manifold complete with: Shut-off valves that can be replaced by thermo-electric actuators Includes Grundfos UPMS 15-58U pump Models with "IN" suffix are built inverted with tubing connections going upward connection: 3/4" PRS. Outlet Connection: 3/4" M (non usare), 8 outlets. Maximum operating pressure: 150 psi. Adjustment temperature range: 80 – 130 °F. Maximum inlet temperature: 195 °F. Outlet center distance: 2 ". Type of pump: UPS 15-58.
3D models
Tender text
CALEFFI, 1725H1A IN. Low temperature manifold mixing station (with 3-speed pump) Supply manifold complete with: Flow meters Adjustable balancing valves Return manifold complete with: Shut-off valves that can be replaced by thermo-electric actuators Includes Grundfos UPMS 15-58U pump Models with "IN" suffix are built inverted with tubing connections going upward connection: 3/4" PRS. Outlet Connection: 3/4" M (non usare), 8 outlets. Maximum operating pressure: 150 psi. Adjustment temperature range: 80 – 130 °F. Maximum inlet temperature: 195 °F. Outlet center distance: 2 ". Type of pump: UPS 15-58.
3D models
Tender text
CALEFFI, 1725I1A. Low temperature manifold mixing station (with 3-speed pump) Supply manifold complete with: Flow meters Adjustable balancing valves Return manifold complete with: Shut-off valves that can be replaced by thermo-electric actuators Includes Grundfos UPMS 15-58U pump Models with "IN" suffix are built inverted with tubing connections going upward connection: 3/4" PRS. Outlet Connection: 3/4" M (non usare), 9 outlets. Maximum operating pressure: 150 psi. Adjustment temperature range: 80 – 130 °F. Maximum inlet temperature: 195 °F. Outlet center distance: 2 ". Type of pump: UPS 15-58.
3D models
Tender text
CALEFFI, 1725I1A IN. Low temperature manifold mixing station (with 3-speed pump) Supply manifold complete with: Flow meters Adjustable balancing valves Return manifold complete with: Shut-off valves that can be replaced by thermo-electric actuators Includes Grundfos UPMS 15-58U pump Models with "IN" suffix are built inverted with tubing connections going upward connection: 3/4" PRS. Outlet Connection: 3/4" M (non usare), 9 outlets. Maximum operating pressure: 150 psi. Adjustment temperature range: 80 – 130 °F. Maximum inlet temperature: 195 °F. Outlet center distance: 2 ". Type of pump: UPS 15-58.
3D models
Tender text
CALEFFI, 1725L1A. Low temperature manifold mixing station (with 3-speed pump) Supply manifold complete with: Flow meters Adjustable balancing valves Return manifold complete with: Shut-off valves that can be replaced by thermo-electric actuators Includes Grundfos UPMS 15-58U pump Models with "IN" suffix are built inverted with tubing connections going upward connection: 3/4" PRS. Outlet Connection: 3/4" M (non usare), 10 outlets. Maximum operating pressure: 150 psi. Adjustment temperature range: 80 – 130 °F. Maximum inlet temperature: 195 °F. Outlet center distance: 2 ". Type of pump: UPS 15-58.
3D models
Tender text
CALEFFI, 1725L1A IN. Low temperature manifold mixing station (with 3-speed pump) Supply manifold complete with: Flow meters Adjustable balancing valves Return manifold complete with: Shut-off valves that can be replaced by thermo-electric actuators Includes Grundfos UPMS 15-58U pump Models with "IN" suffix are built inverted with tubing connections going upward connection: 3/4" PRS. Outlet Connection: 3/4" M (non usare), 10 outlets. Maximum operating pressure: 150 psi. Adjustment temperature range: 80 – 130 °F. Maximum inlet temperature: 195 °F. Outlet center distance: 2 ". Type of pump: UPS 15-58.
3D models
Tender text
CALEFFI, 1725M1A. Low temperature manifold mixing station (with 3-speed pump) Supply manifold complete with: Flow meters Adjustable balancing valves Return manifold complete with: Shut-off valves that can be replaced by thermo-electric actuators Includes Grundfos UPMS 15-58U pump Models with "IN" suffix are built inverted with tubing connections going upward connection: 3/4" PRS. Outlet Connection: 3/4" M (non usare), 11 outlets. Maximum operating pressure: 150 psi. Adjustment temperature range: 80 – 130 °F. Maximum inlet temperature: 195 °F. Outlet center distance: 2 ". Type of pump: UPS 15-58.
3D models
Tender text
CALEFFI, 1725M1A IN. Low temperature manifold mixing station (with 3-speed pump) Supply manifold complete with: Flow meters Adjustable balancing valves Return manifold complete with: Shut-off valves that can be replaced by thermo-electric actuators Includes Grundfos UPMS 15-58U pump Models with "IN" suffix are built inverted with tubing connections going upward connection: 3/4" PRS. Outlet Connection: 3/4" M (non usare), 11 outlets. Maximum operating pressure: 150 psi. Adjustment temperature range: 80 – 130 °F. Maximum inlet temperature: 195 °F. Outlet center distance: 2 ". Type of pump: UPS 15-58.
3D models
Tender text
CALEFFI, 1725N1A. Low temperature manifold mixing station (with 3-speed pump) Supply manifold complete with: Flow meters Adjustable balancing valves Return manifold complete with: Shut-off valves that can be replaced by thermo-electric actuators Includes Grundfos UPMS 15-58U pump Models with "IN" suffix are built inverted with tubing connections going upward connection: 3/4" PRS. Outlet Connection: 3/4" M (non usare), 12 outlets. Maximum operating pressure: 150 psi. Adjustment temperature range: 80 – 130 °F. Maximum inlet temperature: 195 °F. Outlet center distance: 2 ". Type of pump: UPS 15-58.
3D models
Tender text
CALEFFI, 1725N1A IN. Low temperature manifold mixing station (with 3-speed pump) Supply manifold complete with: Flow meters Adjustable balancing valves Return manifold complete with: Shut-off valves that can be replaced by thermo-electric actuators Includes Grundfos UPMS 15-58U pump Models with "IN" suffix are built inverted with tubing connections going upward connection: 3/4" PRS. Outlet Connection: 3/4" M (non usare), 12 outlets. Maximum operating pressure: 150 psi. Adjustment temperature range: 80 – 130 °F. Maximum inlet temperature: 195 °F. Outlet center distance: 2 ". Type of pump: UPS 15-58.
3D models
Tender text
CALEFFI, 1725O1A. Low temperature manifold mixing station (with 3-speed pump) Supply manifold complete with: Flow meters Adjustable balancing valves Return manifold complete with: Shut-off valves that can be replaced by thermo-electric actuators Includes Grundfos UPMS 15-58U pump Models with "IN" suffix are built inverted with tubing connections going upward connection: 3/4" PRS. Outlet Connection: 3/4" M (non usare), 13 outlets. Maximum operating pressure: 150 psi. Adjustment temperature range: 80 – 130 °F. Maximum inlet temperature: 195 °F. Outlet center distance: 2 ". Type of pump: UPS 15-58.
3D models
Tender text
CALEFFI, 1725O1A IN. Low temperature manifold mixing station (with 3-speed pump) Supply manifold complete with: Flow meters Adjustable balancing valves Return manifold complete with: Shut-off valves that can be replaced by thermo-electric actuators Includes Grundfos UPMS 15-58U pump Models with "IN" suffix are built inverted with tubing connections going upward connection: 3/4" PRS. Outlet Connection: 3/4" M (non usare), 13 outlets. Maximum operating pressure: 150 psi. Adjustment temperature range: 80 – 130 °F. Maximum inlet temperature: 195 °F. Outlet center distance: 2 ". Type of pump: UPS 15-58.

Applications

Caleffi Rep Locator
Caleffi Rep Locator

Find your nearest Caleffi Representative