Zone cut-off module with three-way zone valve and distribution manifold.
Product Description
Zone cut-off module with three-way zone valve and distribution manifold.
Complete with:
- recessed box with galvanised backplate and RAL 9010 painted door for interior use, h = 650 mm, depth = 110 (140) mm;
- pair of ball shut-off;
- three-way ball zone valve 6480 series with by-pass tee 6490 series and servomotor 6460 series;
- air vent 5021 series;
- template for heat meter;
- probe holder pocket (flow pocket with strainer mesh);
- connections for domestic water function 794 series or alternatively connections for water function mix 793 series.
Technical data
Electric supply:
230 V AC
Depth:
110–140 mm
Height:
650 mm
Note
If 798 series insulation is requested, the width of the box may increase by 200 mm. Maximum box width 1200 mm.
Download
Drawings and specifications
Part number | Main connection | Outlet connection | Note |
---|---|---|---|
796560 | G 3/4" (ISO 228-1) F |
- |
Without manifolds |
Width
600 mm
|
|||
2D drawings
3D models
Tender text
Zone cut-off module with three-way zone valve and distribution manifold. Complete with:
- recessed box with galvanised backplate and RAL 9010 painted door for interior use, h = 650 mm, depth = 110 (140) mm;
- pair of ball shut-off;
- three-way ball zone valve 6480 series with by-pass tee 6490 series and servomotor 6460 series;
- air vent 5021 series;
- template for heat meter;
- probe holder pocket (flow pocket with strainer mesh);
- connections for domestic water function 794 series or alternatively connections for water function mix 793 series.
Main connection: G 3/4" (ISO 228-1) F. Outlet connection: -. Electric supply: 230 V AC. Depth: 110–140 mm. Height: 650 mm. Width: 600 mm.
SCIP code
53789721-fd15-4d86-955d-83e721c27363
|
|||
79658B | G 3/4" (ISO 228-1) F |
23 p. 1,5 2 outlets |
- |
Width
800 mm
|
|||
3D models
Tender text
Zone cut-off module with three-way zone valve and distribution manifold. Complete with:
- recessed box with galvanised backplate and RAL 9010 painted door for interior use, h = 650 mm, depth = 110 (140) mm;
- pair of ball shut-off;
- three-way ball zone valve 6480 series with by-pass tee 6490 series and servomotor 6460 series;
- air vent 5021 series;
- template for heat meter;
- probe holder pocket (flow pocket with strainer mesh);
- connections for domestic water function 794 series or alternatively connections for water function mix 793 series.
Main connection: G 3/4" (ISO 228-1) F. Outlet connection: 23 p. 1,5, 2 outlets. Electric supply: 230 V AC. Depth: 110–140 mm. Height: 650 mm. Width: 800 mm.
SCIP code
b1837d2d-e7d3-4e51-9a1d-c733192dc423
|
|||
79658C | G 3/4" (ISO 228-1) F |
23 p. 1,5 3 outlets |
- |
Width
800 mm
|
|||
3D models
Tender text
Zone cut-off module with three-way zone valve and distribution manifold. Complete with:
- recessed box with galvanised backplate and RAL 9010 painted door for interior use, h = 650 mm, depth = 110 (140) mm;
- pair of ball shut-off;
- three-way ball zone valve 6480 series with by-pass tee 6490 series and servomotor 6460 series;
- air vent 5021 series;
- template for heat meter;
- probe holder pocket (flow pocket with strainer mesh);
- connections for domestic water function 794 series or alternatively connections for water function mix 793 series.
Main connection: G 3/4" (ISO 228-1) F. Outlet connection: 23 p. 1,5, 3 outlets. Electric supply: 230 V AC. Depth: 110–140 mm. Height: 650 mm. Width: 800 mm.
SCIP code
127d5940-8997-4cf3-826b-ea9cb9cbf102
|
|||
79658D | G 3/4" (ISO 228-1) F |
23 p. 1,5 4 outlets |
- |
Width
800 mm
|
|||
2D drawings
3D models
Tender text
Zone cut-off module with three-way zone valve and distribution manifold. Complete with:
- recessed box with galvanised backplate and RAL 9010 painted door for interior use, h = 650 mm, depth = 110 (140) mm;
- pair of ball shut-off;
- three-way ball zone valve 6480 series with by-pass tee 6490 series and servomotor 6460 series;
- air vent 5021 series;
- template for heat meter;
- probe holder pocket (flow pocket with strainer mesh);
- connections for domestic water function 794 series or alternatively connections for water function mix 793 series.
Main connection: G 3/4" (ISO 228-1) F. Outlet connection: 23 p. 1,5, 4 outlets. Electric supply: 230 V AC. Depth: 110–140 mm. Height: 650 mm. Width: 800 mm.
SCIP code
174bbfff-b804-4dc5-a9be-0fcb05b61186
|
|||
79658E | G 3/4" (ISO 228-1) F |
23 p. 1,5 5 outlets |
- |
Width
800 mm
|
|||
3D models
Tender text
Zone cut-off module with three-way zone valve and distribution manifold. Complete with:
- recessed box with galvanised backplate and RAL 9010 painted door for interior use, h = 650 mm, depth = 110 (140) mm;
- pair of ball shut-off;
- three-way ball zone valve 6480 series with by-pass tee 6490 series and servomotor 6460 series;
- air vent 5021 series;
- template for heat meter;
- probe holder pocket (flow pocket with strainer mesh);
- connections for domestic water function 794 series or alternatively connections for water function mix 793 series.
Main connection: G 3/4" (ISO 228-1) F. Outlet connection: 23 p. 1,5, 5 outlets. Electric supply: 230 V AC. Depth: 110–140 mm. Height: 650 mm. Width: 800 mm.
SCIP code
b0758730-c73f-4bd1-ab21-1e35b1364b34
|
|||
79658F | G 3/4" (ISO 228-1) F |
23 p. 1,5 6 outlets |
- |
Width
1000 mm
|
|||
3D models
Tender text
Zone cut-off module with three-way zone valve and distribution manifold. Complete with:
- recessed box with galvanised backplate and RAL 9010 painted door for interior use, h = 650 mm, depth = 110 (140) mm;
- pair of ball shut-off;
- three-way ball zone valve 6480 series with by-pass tee 6490 series and servomotor 6460 series;
- air vent 5021 series;
- template for heat meter;
- probe holder pocket (flow pocket with strainer mesh);
- connections for domestic water function 794 series or alternatively connections for water function mix 793 series.
Main connection: G 3/4" (ISO 228-1) F. Outlet connection: 23 p. 1,5, 6 outlets. Electric supply: 230 V AC. Depth: 110–140 mm. Height: 650 mm. Width: 1000 mm.
SCIP code
24a08d9c-2439-42ed-a2de-795f425c2217
|
|||
79651G | G 3/4" (ISO 228-1) F |
23 p. 1,5 7 outlets |
- |
Width
1000 mm
|
|||
3D models
Tender text
Zone cut-off module with three-way zone valve and distribution manifold. Complete with:
- recessed box with galvanised backplate and RAL 9010 painted door for interior use, h = 650 mm, depth = 110 (140) mm;
- pair of ball shut-off;
- three-way ball zone valve 6480 series with by-pass tee 6490 series and servomotor 6460 series;
- air vent 5021 series;
- template for heat meter;
- probe holder pocket (flow pocket with strainer mesh);
- connections for domestic water function 794 series or alternatively connections for water function mix 793 series.
Main connection: G 3/4" (ISO 228-1) F. Outlet connection: 23 p. 1,5, 7 outlets. Electric supply: 230 V AC. Depth: 110–140 mm. Height: 650 mm. Width: 1000 mm.
SCIP code
7a8c573f-d0d6-41a5-b2c6-e20f1f1eeeff
|
|||
79651H | G 3/4" (ISO 228-1) F |
23 p. 1,5 8 outlets |
- |
Width
1000 mm
|
|||
3D models
Tender text
Zone cut-off module with three-way zone valve and distribution manifold. Complete with:
- recessed box with galvanised backplate and RAL 9010 painted door for interior use, h = 650 mm, depth = 110 (140) mm;
- pair of ball shut-off;
- three-way ball zone valve 6480 series with by-pass tee 6490 series and servomotor 6460 series;
- air vent 5021 series;
- template for heat meter;
- probe holder pocket (flow pocket with strainer mesh);
- connections for domestic water function 794 series or alternatively connections for water function mix 793 series.
Main connection: G 3/4" (ISO 228-1) F. Outlet connection: 23 p. 1,5, 8 outlets. Electric supply: 230 V AC. Depth: 110–140 mm. Height: 650 mm. Width: 1000 mm.
SCIP code
7e8ce0f2-e4b0-4b1f-a71d-a9529a5e5e8b
|
|||
796680 | G 1" (ISO 228-1) F |
- |
Without manifolds |
Width
800 mm
|
|||
2D drawings
3D models
Tender text
Zone cut-off module with three-way zone valve and distribution manifold. Complete with:
- recessed box with galvanised backplate and RAL 9010 painted door for interior use, h = 650 mm, depth = 110 (140) mm;
- pair of ball shut-off;
- three-way ball zone valve 6480 series with by-pass tee 6490 series and servomotor 6460 series;
- air vent 5021 series;
- template for heat meter;
- probe holder pocket (flow pocket with strainer mesh);
- connections for domestic water function 794 series or alternatively connections for water function mix 793 series.
Main connection: G 1" (ISO 228-1) F. Outlet connection: -. Electric supply: 230 V AC. Depth: 110–140 mm. Height: 650 mm. Width: 800 mm.
SCIP code
9cf9dce6-a2eb-4cec-ad4a-95c4a5a4e8b4
|
|||
79661C | G 1" (ISO 228-1) F |
23 p. 1,5 3 outlets |
- |
Width
1000 mm
|
|||
3D models
Tender text
Zone cut-off module with three-way zone valve and distribution manifold. Complete with:
- recessed box with galvanised backplate and RAL 9010 painted door for interior use, h = 650 mm, depth = 110 (140) mm;
- pair of ball shut-off;
- three-way ball zone valve 6480 series with by-pass tee 6490 series and servomotor 6460 series;
- air vent 5021 series;
- template for heat meter;
- probe holder pocket (flow pocket with strainer mesh);
- connections for domestic water function 794 series or alternatively connections for water function mix 793 series.
Main connection: G 1" (ISO 228-1) F. Outlet connection: 23 p. 1,5, 3 outlets. Electric supply: 230 V AC. Depth: 110–140 mm. Height: 650 mm. Width: 1000 mm.
SCIP code
15ebf3fc-d0ea-4f26-ad0b-86941b37abc0
|
|||
79661D | G 1" (ISO 228-1) F |
23 p. 1,5 4 outlets |
- |
Width
1000 mm
|
|||
3D models
Tender text
Zone cut-off module with three-way zone valve and distribution manifold. Complete with:
- recessed box with galvanised backplate and RAL 9010 painted door for interior use, h = 650 mm, depth = 110 (140) mm;
- pair of ball shut-off;
- three-way ball zone valve 6480 series with by-pass tee 6490 series and servomotor 6460 series;
- air vent 5021 series;
- template for heat meter;
- probe holder pocket (flow pocket with strainer mesh);
- connections for domestic water function 794 series or alternatively connections for water function mix 793 series.
Main connection: G 1" (ISO 228-1) F. Outlet connection: 23 p. 1,5, 4 outlets. Electric supply: 230 V AC. Depth: 110–140 mm. Height: 650 mm. Width: 1000 mm.
SCIP code
76327ab7-488c-4162-9973-01664bdfd3f1
|
|||
79661E | G 1" (ISO 228-1) F |
23 p. 1,5 5 outlets |
- |
Width
1000 mm
|
|||
3D models
Tender text
Zone cut-off module with three-way zone valve and distribution manifold. Complete with:
- recessed box with galvanised backplate and RAL 9010 painted door for interior use, h = 650 mm, depth = 110 (140) mm;
- pair of ball shut-off;
- three-way ball zone valve 6480 series with by-pass tee 6490 series and servomotor 6460 series;
- air vent 5021 series;
- template for heat meter;
- probe holder pocket (flow pocket with strainer mesh);
- connections for domestic water function 794 series or alternatively connections for water function mix 793 series.
Main connection: G 1" (ISO 228-1) F. Outlet connection: 23 p. 1,5, 5 outlets. Electric supply: 230 V AC. Depth: 110–140 mm. Height: 650 mm. Width: 1000 mm.
SCIP code
94cf1a35-b90f-403e-84bd-dd3824e09a39
|
|||
79661F | G 1" (ISO 228-1) F |
23 p. 1,5 6 outlets |
- |
Width
1000 mm
|
|||
3D models
Tender text
Zone cut-off module with three-way zone valve and distribution manifold. Complete with:
- recessed box with galvanised backplate and RAL 9010 painted door for interior use, h = 650 mm, depth = 110 (140) mm;
- pair of ball shut-off;
- three-way ball zone valve 6480 series with by-pass tee 6490 series and servomotor 6460 series;
- air vent 5021 series;
- template for heat meter;
- probe holder pocket (flow pocket with strainer mesh);
- connections for domestic water function 794 series or alternatively connections for water function mix 793 series.
Main connection: G 1" (ISO 228-1) F. Outlet connection: 23 p. 1,5, 6 outlets. Electric supply: 230 V AC. Depth: 110–140 mm. Height: 650 mm. Width: 1000 mm.
SCIP code
087fbef7-7b5c-4bca-943f-306f662d80b4
|
|||
79662G | G 1" (ISO 228-1) F |
23 p. 1,5 7 outlets |
- |
Width
1200 mm
|
|||
3D models
Tender text
Zone cut-off module with three-way zone valve and distribution manifold. Complete with:
- recessed box with galvanised backplate and RAL 9010 painted door for interior use, h = 650 mm, depth = 110 (140) mm;
- pair of ball shut-off;
- three-way ball zone valve 6480 series with by-pass tee 6490 series and servomotor 6460 series;
- air vent 5021 series;
- template for heat meter;
- probe holder pocket (flow pocket with strainer mesh);
- connections for domestic water function 794 series or alternatively connections for water function mix 793 series.
Main connection: G 1" (ISO 228-1) F. Outlet connection: 23 p. 1,5, 7 outlets. Electric supply: 230 V AC. Depth: 110–140 mm. Height: 650 mm. Width: 1200 mm.
SCIP code
39c2a70d-dd24-4bfd-bae0-0f9fbf25e226
|
|||
79662H | G 1" (ISO 228-1) F |
23 p. 1,5 8 outlets |
- |
Width
1200 mm
|
|||
3D models
Tender text
Zone cut-off module with three-way zone valve and distribution manifold. Complete with:
- recessed box with galvanised backplate and RAL 9010 painted door for interior use, h = 650 mm, depth = 110 (140) mm;
- pair of ball shut-off;
- three-way ball zone valve 6480 series with by-pass tee 6490 series and servomotor 6460 series;
- air vent 5021 series;
- template for heat meter;
- probe holder pocket (flow pocket with strainer mesh);
- connections for domestic water function 794 series or alternatively connections for water function mix 793 series.
Main connection: G 1" (ISO 228-1) F. Outlet connection: 23 p. 1,5, 8 outlets. Electric supply: 230 V AC. Depth: 110–140 mm. Height: 650 mm. Width: 1200 mm.
SCIP code
bc05bf4b-107e-4ef5-86a1-390bd7a56718
|
|||
79662I | G 1" (ISO 228-1) F |
23 p. 1,5 9 outlets |
- |
Width
1200 mm
|
|||
3D models
Tender text
Zone cut-off module with three-way zone valve and distribution manifold. Complete with:
- recessed box with galvanised backplate and RAL 9010 painted door for interior use, h = 650 mm, depth = 110 (140) mm;
- pair of ball shut-off;
- three-way ball zone valve 6480 series with by-pass tee 6490 series and servomotor 6460 series;
- air vent 5021 series;
- template for heat meter;
- probe holder pocket (flow pocket with strainer mesh);
- connections for domestic water function 794 series or alternatively connections for water function mix 793 series.
Main connection: G 1" (ISO 228-1) F. Outlet connection: 23 p. 1,5, 9 outlets. Electric supply: 230 V AC. Depth: 110–140 mm. Height: 650 mm. Width: 1200 mm.
SCIP code
8015d04b-bf99-4daa-aad4-b1aae4180912
|
|||
79662L | G 1" (ISO 228-1) F |
23 p. 1,5 10 outlets |
- |
Width
1200 mm
|
|||
3D models
Tender text
Zone cut-off module with three-way zone valve and distribution manifold. Complete with:
- recessed box with galvanised backplate and RAL 9010 painted door for interior use, h = 650 mm, depth = 110 (140) mm;
- pair of ball shut-off;
- three-way ball zone valve 6480 series with by-pass tee 6490 series and servomotor 6460 series;
- air vent 5021 series;
- template for heat meter;
- probe holder pocket (flow pocket with strainer mesh);
- connections for domestic water function 794 series or alternatively connections for water function mix 793 series.
Main connection: G 1" (ISO 228-1) F. Outlet connection: 23 p. 1,5, 10 outlets. Electric supply: 230 V AC. Depth: 110–140 mm. Height: 650 mm. Width: 1200 mm.
SCIP code
2074133b-dfbf-4119-a099-e25ea02d3bd5
|
|||
796780 | G 1 1/4" (ISO 228-1) F |
- |
Without manifolds |
Width
800 mm
|
|||
2D drawings
3D models
Tender text
Zone cut-off module with three-way zone valve and distribution manifold. Complete with:
- recessed box with galvanised backplate and RAL 9010 painted door for interior use, h = 650 mm, depth = 110 (140) mm;
- pair of ball shut-off;
- three-way ball zone valve 6480 series with by-pass tee 6490 series and servomotor 6460 series;
- air vent 5021 series;
- template for heat meter;
- probe holder pocket (flow pocket with strainer mesh);
- connections for domestic water function 794 series or alternatively connections for water function mix 793 series.
Main connection: G 1 1/4" (ISO 228-1) F. Outlet connection: -. Electric supply: 230 V AC. Depth: 110–140 mm. Height: 650 mm. Width: 800 mm.
SCIP code
b4f02773-02fc-44da-b835-68270eae3d69
|
|||
79671C | G 1 1/4" (ISO 228-1) F |
G 3/4" A (ISO 228-1) M 3 outlets |
- |
Width
1000 mm
|
|||
3D models
Tender text
Zone cut-off module with three-way zone valve and distribution manifold. Complete with:
- recessed box with galvanised backplate and RAL 9010 painted door for interior use, h = 650 mm, depth = 110 (140) mm;
- pair of ball shut-off;
- three-way ball zone valve 6480 series with by-pass tee 6490 series and servomotor 6460 series;
- air vent 5021 series;
- template for heat meter;
- probe holder pocket (flow pocket with strainer mesh);
- connections for domestic water function 794 series or alternatively connections for water function mix 793 series.
Main connection: G 1 1/4" (ISO 228-1) F. Outlet connection: G 3/4" A (ISO 228-1) M, 3 outlets. Electric supply: 230 V AC. Depth: 110–140 mm. Height: 650 mm. Width: 1000 mm.
SCIP code
e3eb51ed-f8c9-45e7-9154-40b8c5a45eaf
|
|||
79671D | G 1 1/4" (ISO 228-1) F |
G 3/4" A (ISO 228-1) M 4 outlets |
- |
Width
1000 mm
|
|||
3D models
Tender text
Zone cut-off module with three-way zone valve and distribution manifold. Complete with:
- recessed box with galvanised backplate and RAL 9010 painted door for interior use, h = 650 mm, depth = 110 (140) mm;
- pair of ball shut-off;
- three-way ball zone valve 6480 series with by-pass tee 6490 series and servomotor 6460 series;
- air vent 5021 series;
- template for heat meter;
- probe holder pocket (flow pocket with strainer mesh);
- connections for domestic water function 794 series or alternatively connections for water function mix 793 series.
Main connection: G 1 1/4" (ISO 228-1) F. Outlet connection: G 3/4" A (ISO 228-1) M, 4 outlets. Electric supply: 230 V AC. Depth: 110–140 mm. Height: 650 mm. Width: 1000 mm.
SCIP code
d85b3607-b1f8-4d16-a23e-c84d255796f4
|
|||
79672E | G 1 1/4" (ISO 228-1) F |
G 3/4" A (ISO 228-1) M 5 outlets |
- |
Width
1200 mm
|
|||
3D models
Tender text
Zone cut-off module with three-way zone valve and distribution manifold. Complete with:
- recessed box with galvanised backplate and RAL 9010 painted door for interior use, h = 650 mm, depth = 110 (140) mm;
- pair of ball shut-off;
- three-way ball zone valve 6480 series with by-pass tee 6490 series and servomotor 6460 series;
- air vent 5021 series;
- template for heat meter;
- probe holder pocket (flow pocket with strainer mesh);
- connections for domestic water function 794 series or alternatively connections for water function mix 793 series.
Main connection: G 1 1/4" (ISO 228-1) F. Outlet connection: G 3/4" A (ISO 228-1) M, 5 outlets. Electric supply: 230 V AC. Depth: 110–140 mm. Height: 650 mm. Width: 1200 mm.
SCIP code
8e34fe86-d66b-47ea-a3b4-b4cfc1c35f0f
|
|||
79672F | G 1 1/4" (ISO 228-1) F |
G 3/4" A (ISO 228-1) M 6 outlets |
- |
Width
1200 mm
|
|||
3D models
Tender text
Zone cut-off module with three-way zone valve and distribution manifold. Complete with:
- recessed box with galvanised backplate and RAL 9010 painted door for interior use, h = 650 mm, depth = 110 (140) mm;
- pair of ball shut-off;
- three-way ball zone valve 6480 series with by-pass tee 6490 series and servomotor 6460 series;
- air vent 5021 series;
- template for heat meter;
- probe holder pocket (flow pocket with strainer mesh);
- connections for domestic water function 794 series or alternatively connections for water function mix 793 series.
Main connection: G 1 1/4" (ISO 228-1) F. Outlet connection: G 3/4" A (ISO 228-1) M, 6 outlets. Electric supply: 230 V AC. Depth: 110–140 mm. Height: 650 mm. Width: 1200 mm.
SCIP code
3f57436b-faf6-4f10-a38e-5c5c5c435537
|
|||
79672G | G 1 1/4" (ISO 228-1) F |
G 3/4" A (ISO 228-1) M 7 outlets |
- |
Width
1200 mm
|
|||
3D models
Tender text
Zone cut-off module with three-way zone valve and distribution manifold. Complete with:
- recessed box with galvanised backplate and RAL 9010 painted door for interior use, h = 650 mm, depth = 110 (140) mm;
- pair of ball shut-off;
- three-way ball zone valve 6480 series with by-pass tee 6490 series and servomotor 6460 series;
- air vent 5021 series;
- template for heat meter;
- probe holder pocket (flow pocket with strainer mesh);
- connections for domestic water function 794 series or alternatively connections for water function mix 793 series.
Main connection: G 1 1/4" (ISO 228-1) F. Outlet connection: G 3/4" A (ISO 228-1) M, 7 outlets. Electric supply: 230 V AC. Depth: 110–140 mm. Height: 650 mm. Width: 1200 mm.
SCIP code
4e2b3ccd-2cba-4eb1-a584-db575567bb88
|
|||
79672H | G 1 1/4" (ISO 228-1) F |
G 3/4" A (ISO 228-1) M 8 outlets |
- |
Width
1200 mm
|
|||
3D models
Tender text
Zone cut-off module with three-way zone valve and distribution manifold. Complete with:
- recessed box with galvanised backplate and RAL 9010 painted door for interior use, h = 650 mm, depth = 110 (140) mm;
- pair of ball shut-off;
- three-way ball zone valve 6480 series with by-pass tee 6490 series and servomotor 6460 series;
- air vent 5021 series;
- template for heat meter;
- probe holder pocket (flow pocket with strainer mesh);
- connections for domestic water function 794 series or alternatively connections for water function mix 793 series.
Main connection: G 1 1/4" (ISO 228-1) F. Outlet connection: G 3/4" A (ISO 228-1) M, 8 outlets. Electric supply: 230 V AC. Depth: 110–140 mm. Height: 650 mm. Width: 1200 mm.
SCIP code
01394d8f-0c2d-483f-b9af-d72e9b40f2fe
|