Series 182

Set point regulating unit pre-assembled, with medium distribution kit for primary circuit.

Go to
1826d5a2l002.png
Download high resolution

Product Description

Set point regulating unit pre-assembled, with medium distribution kit for primary circuit.
Complete with:
- thermostatic set point regulating unit;
- medium distribution kit with built-in lockshields and shut-off valves for primary circuit;
- distribution manifolds in composite with built-in flow meters and shut-off valves;
- primary circuit by-pass kit;
- safety thermostat;
- high-efficiency pump, UPM3S Auto 25-60.

Technical data

Maximum working pressure: 6 bar
Adjustment temperature range: 25–55 °C
Electric supply: 230 V (AC)

Certifications

CE

Drawings and specifications

Part number Connection Outlet connection Radiator connection
Width
800
3D models
Tender text
Set point regulating unit pre-assembled, with medium distribution kit for primary circuit. Complete with: - thermostatic set point regulating unit; - medium distribution kit with built-in lockshields and shut-off valves for primary circuit; - distribution manifolds in composite with built-in flow meters and shut-off valves; - primary circuit by-pass kit; - safety thermostat; - high-efficiency pump, UPM3S Auto 25-60. Connection: G 1" (ISO 228-1) F, Connection for Caleffi fittings. outlet connection: G 3/4" A (ISO 228-1) M, 3 outlets. radiator connection: G 3/4" A (ISO 228-1) M, 2 outlets. Maximum working pressure: 6 bar. Adjustment temperature range: 25–55 °C. Electric supply: 230 V (AC). Width: 800.
SCIP code
034f96cd-6f00-4933-b4f4-24c0ef729e5b
Width
800
3D models
Tender text
Set point regulating unit pre-assembled, with medium distribution kit for primary circuit. Complete with: - thermostatic set point regulating unit; - medium distribution kit with built-in lockshields and shut-off valves for primary circuit; - distribution manifolds in composite with built-in flow meters and shut-off valves; - primary circuit by-pass kit; - safety thermostat; - high-efficiency pump, UPM3S Auto 25-60. Connection: G 1" (ISO 228-1) F, Connection for Caleffi fittings. outlet connection: G 3/4" A (ISO 228-1) M, 4 outlets. radiator connection: G 3/4" A (ISO 228-1) M, 2 outlets. Maximum working pressure: 6 bar. Adjustment temperature range: 25–55 °C. Electric supply: 230 V (AC). Width: 800.
SCIP code
91d51799-f718-4633-81f4-00a2299c1246
Width
800
3D models
Tender text
Set point regulating unit pre-assembled, with medium distribution kit for primary circuit. Complete with: - thermostatic set point regulating unit; - medium distribution kit with built-in lockshields and shut-off valves for primary circuit; - distribution manifolds in composite with built-in flow meters and shut-off valves; - primary circuit by-pass kit; - safety thermostat; - high-efficiency pump, UPM3S Auto 25-60. Connection: G 1" (ISO 228-1) F, Connection for Caleffi fittings. outlet connection: G 3/4" A (ISO 228-1) M, 5 outlets. radiator connection: G 3/4" A (ISO 228-1) M, 2 outlets. Maximum working pressure: 6 bar. Adjustment temperature range: 25–55 °C. Electric supply: 230 V (AC). Width: 800.
SCIP code
8d393098-f2df-4c81-afd2-ff3bb22de446
Width
1000
3D models
Tender text
Set point regulating unit pre-assembled, with medium distribution kit for primary circuit. Complete with: - thermostatic set point regulating unit; - medium distribution kit with built-in lockshields and shut-off valves for primary circuit; - distribution manifolds in composite with built-in flow meters and shut-off valves; - primary circuit by-pass kit; - safety thermostat; - high-efficiency pump, UPM3S Auto 25-60. Connection: G 1" (ISO 228-1) F, Connection for Caleffi fittings. outlet connection: G 3/4" A (ISO 228-1) M, 6 outlets. radiator connection: G 3/4" A (ISO 228-1) M, 2 outlets. Maximum working pressure: 6 bar. Adjustment temperature range: 25–55 °C. Electric supply: 230 V (AC). Width: 1000.
SCIP code
905420c5-4434-49be-9d61-25b676daf7a2
Width
1000
3D models
Tender text
Set point regulating unit pre-assembled, with medium distribution kit for primary circuit. Complete with: - thermostatic set point regulating unit; - medium distribution kit with built-in lockshields and shut-off valves for primary circuit; - distribution manifolds in composite with built-in flow meters and shut-off valves; - primary circuit by-pass kit; - safety thermostat; - high-efficiency pump, UPM3S Auto 25-60. Connection: G 1" (ISO 228-1) F, Connection for Caleffi fittings. outlet connection: G 3/4" A (ISO 228-1) M, 7 outlets. radiator connection: G 3/4" A (ISO 228-1) M, 2 outlets. Maximum working pressure: 6 bar. Adjustment temperature range: 25–55 °C. Electric supply: 230 V (AC). Width: 1000.
SCIP code
c2ec2e87-8a91-416a-9489-1e7cae54196b
Width
1000
3D models
Tender text
Set point regulating unit pre-assembled, with medium distribution kit for primary circuit. Complete with: - thermostatic set point regulating unit; - medium distribution kit with built-in lockshields and shut-off valves for primary circuit; - distribution manifolds in composite with built-in flow meters and shut-off valves; - primary circuit by-pass kit; - safety thermostat; - high-efficiency pump, UPM3S Auto 25-60. Connection: G 1" (ISO 228-1) F, Connection for Caleffi fittings. outlet connection: G 3/4" A (ISO 228-1) M, 8 outlets. radiator connection: G 3/4" A (ISO 228-1) M, 2 outlets. Maximum working pressure: 6 bar. Adjustment temperature range: 25–55 °C. Electric supply: 230 V (AC). Width: 1000.
SCIP code
3a386e2e-420b-4736-a76f-018ccdae6695
Width
1000
3D models
Tender text
Set point regulating unit pre-assembled, with medium distribution kit for primary circuit. Complete with: - thermostatic set point regulating unit; - medium distribution kit with built-in lockshields and shut-off valves for primary circuit; - distribution manifolds in composite with built-in flow meters and shut-off valves; - primary circuit by-pass kit; - safety thermostat; - high-efficiency pump, UPM3S Auto 25-60. Connection: G 1" (ISO 228-1) F, Connection for Caleffi fittings. outlet connection: G 3/4" A (ISO 228-1) M, 9 outlets. radiator connection: G 3/4" A (ISO 228-1) M, 2 outlets. Maximum working pressure: 6 bar. Adjustment temperature range: 25–55 °C. Electric supply: 230 V (AC). Width: 1000.
SCIP code
cba862ce-8829-4478-9509-b0b4a6ee75e0
Width
1000
3D models
Tender text
Set point regulating unit pre-assembled, with medium distribution kit for primary circuit. Complete with: - thermostatic set point regulating unit; - medium distribution kit with built-in lockshields and shut-off valves for primary circuit; - distribution manifolds in composite with built-in flow meters and shut-off valves; - primary circuit by-pass kit; - safety thermostat; - high-efficiency pump, UPM3S Auto 25-60. Connection: G 1" (ISO 228-1) F, Connection for Caleffi fittings. outlet connection: G 3/4" A (ISO 228-1) M, 10 outlets. radiator connection: G 3/4" A (ISO 228-1) M, 2 outlets. Maximum working pressure: 6 bar. Adjustment temperature range: 25–55 °C. Electric supply: 230 V (AC). Width: 1000.
SCIP code
f76a67a8-bc3d-4ab4-9d28-de74aaf30701
Width
1200
3D models
Tender text
Set point regulating unit pre-assembled, with medium distribution kit for primary circuit. Complete with: - thermostatic set point regulating unit; - medium distribution kit with built-in lockshields and shut-off valves for primary circuit; - distribution manifolds in composite with built-in flow meters and shut-off valves; - primary circuit by-pass kit; - safety thermostat; - high-efficiency pump, UPM3S Auto 25-60. Connection: G 1" (ISO 228-1) F, Connection for Caleffi fittings. outlet connection: G 3/4" A (ISO 228-1) M, 11 outlets. radiator connection: G 3/4" A (ISO 228-1) M, 2 outlets. Maximum working pressure: 6 bar. Adjustment temperature range: 25–55 °C. Electric supply: 230 V (AC). Width: 1200.
SCIP code
4e30a97e-ab18-40ea-9b6b-6dab3db6a365
Width
1200
3D models
Tender text
Set point regulating unit pre-assembled, with medium distribution kit for primary circuit. Complete with: - thermostatic set point regulating unit; - medium distribution kit with built-in lockshields and shut-off valves for primary circuit; - distribution manifolds in composite with built-in flow meters and shut-off valves; - primary circuit by-pass kit; - safety thermostat; - high-efficiency pump, UPM3S Auto 25-60. Connection: G 1" (ISO 228-1) F, Connection for Caleffi fittings. outlet connection: G 3/4" A (ISO 228-1) M, 12 outlets. radiator connection: G 3/4" A (ISO 228-1) M, 2 outlets. Maximum working pressure: 6 bar. Adjustment temperature range: 25–55 °C. Electric supply: 230 V (AC). Width: 1200.
SCIP code
b2a2b518-fb46-4cef-bec4-2e684a2fcda7
Width
1200
3D models
Tender text
Set point regulating unit pre-assembled, with medium distribution kit for primary circuit. Complete with: - thermostatic set point regulating unit; - medium distribution kit with built-in lockshields and shut-off valves for primary circuit; - distribution manifolds in composite with built-in flow meters and shut-off valves; - primary circuit by-pass kit; - safety thermostat; - high-efficiency pump, UPM3S Auto 25-60. Connection: G 1" (ISO 228-1) F, Connection for Caleffi fittings. outlet connection: G 3/4" A (ISO 228-1) M, 13 outlets. radiator connection: G 3/4" A (ISO 228-1) M, 2 outlets. Maximum working pressure: 6 bar. Adjustment temperature range: 25–55 °C. Electric supply: 230 V (AC). Width: 1200.
SCIP code
b7582fd7-de66-43cb-b22e-2327d0842aef

Applications

Pipe Sizer Caleffi
Pipe Sizer Caleffi

This application allows for sizing and making calculations for pipes and conduits carrying water or air, respectively for hydraulic or aeraulic plants.