Set point regulating unit pre-assembled in inspection wall box, with medium distribution kit for primary circuit.
Product Description
Set point regulating unit pre-assembled in inspection wall box, with medium distribution kit for primary circuit.
Complete with:
- set point thermostatic regulating unit;
- medium distribution kit with built-in lockshields and shut-off valves for primary circuit;
- distribution manifolds in composite with built-in flow meters and shut-off valves;
- primary circuit by-pass kit;
- safety thermostat;
- high-efficiency pump;
- inspection wall box, with floor supports.
Technical data
                        Maximum working pressure:
                        6 bar
                      
                                          
                        Adjustment temperature range:
                        25–55 °C
                      
                                          
                        Electric supply:
                        230 V AC 
                      
                                      Certifications
Download
Drawings and specifications
| Part number | Main connection | Outlet connection | Radiator connection | 
|---|---|---|---|
| 1826C1A2L 002 | G 1" (ISO 228-1) F | 
                      G 3/4" A (ISO 228-1) M 3 outlets  | 
                      G 3/4" A (ISO 228-1) M 2 outlets  | 
                  
| 
             3D models 
                    
                  Tender text 
                      
                      CALEFFI, 1826C1A2L 002.
Set point regulating unit pre-assembled in inspection wall box, with medium distribution kit for primary circuit. Complete with:
- set point thermostatic regulating unit;
- medium distribution kit with built-in lockshields and shut-off valves for primary circuit;
- distribution manifolds in composite with built-in flow meters and shut-off valves;
- primary circuit by-pass kit;
- safety thermostat;
- high-efficiency pump;
- inspection wall box, with floor supports.
 Main connection: G 1" (ISO 228-1) F. Outlet connection: G 3/4" A (ISO 228-1) M, 3 outlets, Connection for Caleffi fittings. Radiator connection: G 3/4" A (ISO 228-1) M, 2 outlets, Connection for Caleffi fittings. Maximum working pressure: 6 bar. Adjustment temperature range: 25–55 °C. Electric supply: 230 V AC. 
                     
                  SCIP code 
                        
                          0f9ab19d-a13b-4915-b77d-54ab3f96d708
                         
                       | 
        |||
| 1826D1A2L 002 | G 1" (ISO 228-1) F | 
                      G 3/4" A (ISO 228-1) M 4 outlets  | 
                      G 3/4" A (ISO 228-1) M 2 outlets  | 
                  
| 
             3D models 
                    
                  Tender text 
                      
                      CALEFFI, 1826D1A2L 002.
Set point regulating unit pre-assembled in inspection wall box, with medium distribution kit for primary circuit. Complete with:
- set point thermostatic regulating unit;
- medium distribution kit with built-in lockshields and shut-off valves for primary circuit;
- distribution manifolds in composite with built-in flow meters and shut-off valves;
- primary circuit by-pass kit;
- safety thermostat;
- high-efficiency pump;
- inspection wall box, with floor supports.
 Main connection: G 1" (ISO 228-1) F. Outlet connection: G 3/4" A (ISO 228-1) M, 4 outlets, Connection for Caleffi fittings. Radiator connection: G 3/4" A (ISO 228-1) M, 2 outlets, Connection for Caleffi fittings. Maximum working pressure: 6 bar. Adjustment temperature range: 25–55 °C. Electric supply: 230 V AC. 
                     
                  SCIP code 
                        
                          6566eff4-ccf8-432b-951a-90a2ef7e04be
                         
                       | 
        |||
| 1826E1A2L 002 | G 1" (ISO 228-1) F | 
                      G 3/4" A (ISO 228-1) M 5 outlets  | 
                      G 3/4" A (ISO 228-1) M 2 outlets  | 
                  
| 
             3D models 
                    
                  Tender text 
                      
                      CALEFFI, 1826E1A2L 002.
Set point regulating unit pre-assembled in inspection wall box, with medium distribution kit for primary circuit. Complete with:
- set point thermostatic regulating unit;
- medium distribution kit with built-in lockshields and shut-off valves for primary circuit;
- distribution manifolds in composite with built-in flow meters and shut-off valves;
- primary circuit by-pass kit;
- safety thermostat;
- high-efficiency pump;
- inspection wall box, with floor supports.
 Main connection: G 1" (ISO 228-1) F. Outlet connection: G 3/4" A (ISO 228-1) M, 5 outlets, Connection for Caleffi fittings. Radiator connection: G 3/4" A (ISO 228-1) M, 2 outlets, Connection for Caleffi fittings. Maximum working pressure: 6 bar. Adjustment temperature range: 25–55 °C. Electric supply: 230 V AC. 
                     
                  SCIP code 
                        
                          aa856a6b-af31-4c5d-be07-37dfb9635859
                         
                       | 
        |||
| 1826F1A2L 002 | G 1" (ISO 228-1) F | 
                      G 3/4" A (ISO 228-1) M 6 outlets  | 
                      G 3/4" A (ISO 228-1) M 2 outlets  | 
                  
| 
             3D models 
                    
                  Tender text 
                      
                      CALEFFI, 1826F1A2L 002.
Set point regulating unit pre-assembled in inspection wall box, with medium distribution kit for primary circuit. Complete with:
- set point thermostatic regulating unit;
- medium distribution kit with built-in lockshields and shut-off valves for primary circuit;
- distribution manifolds in composite with built-in flow meters and shut-off valves;
- primary circuit by-pass kit;
- safety thermostat;
- high-efficiency pump;
- inspection wall box, with floor supports.
 Main connection: G 1" (ISO 228-1) F. Outlet connection: G 3/4" A (ISO 228-1) M, 6 outlets, Connection for Caleffi fittings. Radiator connection: G 3/4" A (ISO 228-1) M, 2 outlets, Connection for Caleffi fittings. Maximum working pressure: 6 bar. Adjustment temperature range: 25–55 °C. Electric supply: 230 V AC. 
                     
                  SCIP code 
                        
                          a5af7a10-7804-4960-a8e0-fe66b6ea6940
                         
                       | 
        |||
| 1826G1A2L 002 | G 1" (ISO 228-1) F | 
                      G 3/4" A (ISO 228-1) M 7 outlets  | 
                      G 3/4" A (ISO 228-1) M 2 outlets  | 
                  
| 
             2D drawings 
                    3D models 
                    
                  Tender text 
                      
                      CALEFFI, 1826G1A2L 002.
Set point regulating unit pre-assembled in inspection wall box, with medium distribution kit for primary circuit. Complete with:
- set point thermostatic regulating unit;
- medium distribution kit with built-in lockshields and shut-off valves for primary circuit;
- distribution manifolds in composite with built-in flow meters and shut-off valves;
- primary circuit by-pass kit;
- safety thermostat;
- high-efficiency pump;
- inspection wall box, with floor supports.
 Main connection: G 1" (ISO 228-1) F. Outlet connection: G 3/4" A (ISO 228-1) M, 7 outlets, Connection for Caleffi fittings. Radiator connection: G 3/4" A (ISO 228-1) M, 2 outlets, Connection for Caleffi fittings. Maximum working pressure: 6 bar. Adjustment temperature range: 25–55 °C. Electric supply: 230 V AC. 
                     
                  SCIP code 
                        
                          1372ebf8-d589-4297-bb5f-a51f6ab7f72d
                         
                       | 
        |||
| 1826H1A2L 002 | G 1" (ISO 228-1) F | 
                      G 3/4" A (ISO 228-1) M 8 outlets  | 
                      G 3/4" A (ISO 228-1) M 2 outlets  | 
                  
| 
             3D models 
                    
                  Tender text 
                      
                      CALEFFI, 1826H1A2L 002.
Set point regulating unit pre-assembled in inspection wall box, with medium distribution kit for primary circuit. Complete with:
- set point thermostatic regulating unit;
- medium distribution kit with built-in lockshields and shut-off valves for primary circuit;
- distribution manifolds in composite with built-in flow meters and shut-off valves;
- primary circuit by-pass kit;
- safety thermostat;
- high-efficiency pump;
- inspection wall box, with floor supports.
 Main connection: G 1" (ISO 228-1) F. Outlet connection: G 3/4" A (ISO 228-1) M, 8 outlets, Connection for Caleffi fittings. Radiator connection: G 3/4" A (ISO 228-1) M, 2 outlets, Connection for Caleffi fittings. Maximum working pressure: 6 bar. Adjustment temperature range: 25–55 °C. Electric supply: 230 V AC. 
                     
                  SCIP code 
                        
                          a57a1da3-51cf-4e65-948d-84dcf788f8d6
                         
                       | 
        |||
| 1826I1A2L 002 | G 1" (ISO 228-1) F | 
                      G 3/4" A (ISO 228-1) M 9 outlets  | 
                      G 3/4" A (ISO 228-1) M 2 outlets  | 
                  
| 
             3D models 
                    
                  Tender text 
                      
                      CALEFFI, 1826I1A2L 002.
Set point regulating unit pre-assembled in inspection wall box, with medium distribution kit for primary circuit. Complete with:
- set point thermostatic regulating unit;
- medium distribution kit with built-in lockshields and shut-off valves for primary circuit;
- distribution manifolds in composite with built-in flow meters and shut-off valves;
- primary circuit by-pass kit;
- safety thermostat;
- high-efficiency pump;
- inspection wall box, with floor supports.
 Main connection: G 1" (ISO 228-1) F. Outlet connection: G 3/4" A (ISO 228-1) M, 9 outlets, Connection for Caleffi fittings. Radiator connection: G 3/4" A (ISO 228-1) M, 2 outlets, Connection for Caleffi fittings. Maximum working pressure: 6 bar. Adjustment temperature range: 25–55 °C. Electric supply: 230 V AC. 
                     
                  SCIP code 
                        
                          8531f9cf-4fb0-4f65-b2d3-b375c8984bd4
                         
                       | 
        |||
| 1826L1A2L 002 | G 1" (ISO 228-1) F | 
                      G 3/4" A (ISO 228-1) M 10 outlets  | 
                      G 3/4" A (ISO 228-1) M 2 outlets  | 
                  
| 
             3D models 
                    
                  Tender text 
                      
                      CALEFFI, 1826L1A2L 002.
Set point regulating unit pre-assembled in inspection wall box, with medium distribution kit for primary circuit. Complete with:
- set point thermostatic regulating unit;
- medium distribution kit with built-in lockshields and shut-off valves for primary circuit;
- distribution manifolds in composite with built-in flow meters and shut-off valves;
- primary circuit by-pass kit;
- safety thermostat;
- high-efficiency pump;
- inspection wall box, with floor supports.
 Main connection: G 1" (ISO 228-1) F. Outlet connection: G 3/4" A (ISO 228-1) M, 10 outlets, Connection for Caleffi fittings. Radiator connection: G 3/4" A (ISO 228-1) M, 2 outlets, Connection for Caleffi fittings. Maximum working pressure: 6 bar. Adjustment temperature range: 25–55 °C. Electric supply: 230 V AC. 
                     
                  SCIP code 
                        
                          40d380c8-ee2a-4b62-aacd-e55831d11421
                         
                       | 
        |||
| 1826M1A2L 002 | G 1" (ISO 228-1) F | 
                      G 3/4" A (ISO 228-1) M 11 outlets  | 
                      G 3/4" A (ISO 228-1) M 2 outlets  | 
                  
| 
             3D models 
                    
                  Tender text 
                      
                      CALEFFI, 1826M1A2L 002.
Set point regulating unit pre-assembled in inspection wall box, with medium distribution kit for primary circuit. Complete with:
- set point thermostatic regulating unit;
- medium distribution kit with built-in lockshields and shut-off valves for primary circuit;
- distribution manifolds in composite with built-in flow meters and shut-off valves;
- primary circuit by-pass kit;
- safety thermostat;
- high-efficiency pump;
- inspection wall box, with floor supports.
 Main connection: G 1" (ISO 228-1) F. Outlet connection: G 3/4" A (ISO 228-1) M, 11 outlets, Connection for Caleffi fittings. Radiator connection: G 3/4" A (ISO 228-1) M, 2 outlets, Connection for Caleffi fittings. Maximum working pressure: 6 bar. Adjustment temperature range: 25–55 °C. Electric supply: 230 V AC. 
                     
                  SCIP code 
                        
                          7676bad1-3680-49f3-b923-8e45b4451b21
                         
                       | 
        |||
| 1826N1A2L 002 | G 1" (ISO 228-1) F | 
                      G 3/4" A (ISO 228-1) M 12 outlets  | 
                      G 3/4" A (ISO 228-1) M 2 outlets  | 
                  
| 
             2D drawings 
                    3D models 
                    
                  Tender text 
                      
                      CALEFFI, 1826N1A2L 002.
Set point regulating unit pre-assembled in inspection wall box, with medium distribution kit for primary circuit. Complete with:
- set point thermostatic regulating unit;
- medium distribution kit with built-in lockshields and shut-off valves for primary circuit;
- distribution manifolds in composite with built-in flow meters and shut-off valves;
- primary circuit by-pass kit;
- safety thermostat;
- high-efficiency pump;
- inspection wall box, with floor supports.
 Main connection: G 1" (ISO 228-1) F. Outlet connection: G 3/4" A (ISO 228-1) M, 12 outlets, Connection for Caleffi fittings. Radiator connection: G 3/4" A (ISO 228-1) M, 2 outlets, Connection for Caleffi fittings. Maximum working pressure: 6 bar. Adjustment temperature range: 25–55 °C. Electric supply: 230 V AC. 
                     
                  SCIP code 
                        
                          66c45064-7438-4e05-8a0a-11ae8bb8ab6c
                         
                       | 
        |||
| 1826O1A2L 002 | G 1" (ISO 228-1) F | 
                      G 3/4" A (ISO 228-1) M 13 outlets  | 
                      G 3/4" A (ISO 228-1) M 2 outlets  | 
                  
| 
             3D models 
                    
                  Tender text 
                      
                      CALEFFI, 1826O1A2L 002.
Set point regulating unit pre-assembled in inspection wall box, with medium distribution kit for primary circuit. Complete with:
- set point thermostatic regulating unit;
- medium distribution kit with built-in lockshields and shut-off valves for primary circuit;
- distribution manifolds in composite with built-in flow meters and shut-off valves;
- primary circuit by-pass kit;
- safety thermostat;
- high-efficiency pump;
- inspection wall box, with floor supports.
 Main connection: G 1" (ISO 228-1) F. Outlet connection: G 3/4" A (ISO 228-1) M, 13 outlets, Connection for Caleffi fittings. Radiator connection: G 3/4" A (ISO 228-1) M, 2 outlets, Connection for Caleffi fittings. Maximum working pressure: 6 bar. Adjustment temperature range: 25–55 °C. Electric supply: 230 V AC. 
                     
                  SCIP code 
                        
                          47024d5c-af75-45f7-b22f-9f58a42ebc16
                         
                       | 
        |||