Preassembled geothermal manifold.
Product Description
Preassembled geothermal manifold.
Complete with:
- automatic air vent;
- Ø80 mm temperature gauges;
- filler/drain cocks;
- composite flow and return manifolds;
- end fitting caps with insulation;
- stainless steel wall mounting brackets;
- set of flow direction and circuit identification labels;
- wall anchors.
Outlet connections with mechanical seal for 112 series balancing valves and 871 series ball valves.
Technical data
Maximum working pressure:
6 bar
Maximum hydraulic test pressure:
10 bar
Medium temperature range:
-10–60 °C
Ambient temperature range:
-20–60 °C
Maximum percentage of glycol:
50 %
Medium:
glycol solutions, water
Maximum recommended flow rate:
7 m³/h
DN:
DN 50 (body)
Note
For more than 8 outlet circuits, see the modular manifold.
Download
Drawings and specifications
Part number | Connection | Outlet connection | |
---|---|---|---|
1107B5 | G 1 1/4" (ISO 228-1) F |
42 p.2,5 TR 2 outlets |
|
3D models
Tender text
Preassembled geothermal manifold. Complete with:
- automatic air vent;
- Ø80 mm temperature gauges;
- filler/drain cocks;
- composite flow and return manifolds;
- end fitting caps with insulation;
- stainless steel wall mounting brackets;
- set of flow direction and circuit identification labels;
- wall anchors.
Outlet connections with mechanical seal for 112 series balancing valves and 871 series ball valves. Connection: G 1 1/4" (ISO 228-1) F. Outlet connection: 42 p.2,5 TR, 2 outlets. Maximum working pressure: 6 bar. Maximum hydraulic test pressure: 10 bar. Medium temperature range: -10–60 °C. Ambient temperature range: -20–60 °C. Maximum percentage of glycol: 50 %. Medium: glycol solutions. Maximum recommended flow rate: 7 m³/h. DN: DN 50 (body).
SCIP code
f1dd7568-340c-44ae-b328-25975dc45cc0
|
|||
1107C5 | G 1 1/4" (ISO 228-1) F |
42 p.2,5 TR 3 outlets |
|
2D drawings
3D models
Tender text
Preassembled geothermal manifold. Complete with:
- automatic air vent;
- Ø80 mm temperature gauges;
- filler/drain cocks;
- composite flow and return manifolds;
- end fitting caps with insulation;
- stainless steel wall mounting brackets;
- set of flow direction and circuit identification labels;
- wall anchors.
Outlet connections with mechanical seal for 112 series balancing valves and 871 series ball valves. Connection: G 1 1/4" (ISO 228-1) F. Outlet connection: 42 p.2,5 TR, 3 outlets. Maximum working pressure: 6 bar. Maximum hydraulic test pressure: 10 bar. Medium temperature range: -10–60 °C. Ambient temperature range: -20–60 °C. Maximum percentage of glycol: 50 %. Medium: water. Maximum recommended flow rate: 7 m³/h. DN: DN 50 (body).
SCIP code
52fcd6ec-6a94-44f3-8f42-26fc62720005
|
|||
1107D5 | G 1 1/4" (ISO 228-1) F |
42 p.2,5 TR 4 outlets |
|
2D drawings
3D models
Tender text
Preassembled geothermal manifold. Complete with:
- automatic air vent;
- Ø80 mm temperature gauges;
- filler/drain cocks;
- composite flow and return manifolds;
- end fitting caps with insulation;
- stainless steel wall mounting brackets;
- set of flow direction and circuit identification labels;
- wall anchors.
Outlet connections with mechanical seal for 112 series balancing valves and 871 series ball valves. Connection: G 1 1/4" (ISO 228-1) F. Outlet connection: 42 p.2,5 TR, 4 outlets. Maximum working pressure: 6 bar. Maximum hydraulic test pressure: 10 bar. Medium temperature range: -10–60 °C. Ambient temperature range: -20–60 °C. Maximum percentage of glycol: 50 %. Medium: glycol solutions. Maximum recommended flow rate: 7 m³/h. DN: DN 50 (body).
SCIP code
dadb4ebc-10b0-42a8-9024-a2a6f8e4b525
|
|||
1107E5 | G 1 1/4" (ISO 228-1) F |
42 p.2,5 TR 5 outlets |
|
3D models
Tender text
Preassembled geothermal manifold. Complete with:
- automatic air vent;
- Ø80 mm temperature gauges;
- filler/drain cocks;
- composite flow and return manifolds;
- end fitting caps with insulation;
- stainless steel wall mounting brackets;
- set of flow direction and circuit identification labels;
- wall anchors.
Outlet connections with mechanical seal for 112 series balancing valves and 871 series ball valves. Connection: G 1 1/4" (ISO 228-1) F. Outlet connection: 42 p.2,5 TR, 5 outlets. Maximum working pressure: 6 bar. Medium temperature range: -10–60 °C. Ambient temperature range: -20–60 °C. Maximum percentage of glycol: 50 %. Medium: glycol solutions, water. Maximum recommended flow rate: 7 m³/h. DN: DN 50 (body).
SCIP code
3f1a41df-74cd-4ff7-b527-9c54baa7d6e0
|
|||
1107F5 | G 1 1/4" (ISO 228-1) F |
42 p.2,5 TR 6 outlets |
|
3D models
Tender text
Preassembled geothermal manifold. Complete with:
- automatic air vent;
- Ø80 mm temperature gauges;
- filler/drain cocks;
- composite flow and return manifolds;
- end fitting caps with insulation;
- stainless steel wall mounting brackets;
- set of flow direction and circuit identification labels;
- wall anchors.
Outlet connections with mechanical seal for 112 series balancing valves and 871 series ball valves. Connection: G 1 1/4" (ISO 228-1) F. Outlet connection: 42 p.2,5 TR, 6 outlets. Maximum working pressure: 6 bar. Maximum hydraulic test pressure: 10 bar. Medium temperature range: -10–60 °C. Ambient temperature range: -20–60 °C. Maximum percentage of glycol: 50 %. Medium: glycol solutions. Maximum recommended flow rate: 7 m³/h. DN: DN 50 (body).
SCIP code
a18650b9-7323-425a-9a53-56431b4b8fe8
|
|||
1107G5 | G 1 1/4" (ISO 228-1) F |
42 p.2,5 TR 7 outlets |
|
3D models
Tender text
Preassembled geothermal manifold. Complete with:
- automatic air vent;
- Ø80 mm temperature gauges;
- filler/drain cocks;
- composite flow and return manifolds;
- end fitting caps with insulation;
- stainless steel wall mounting brackets;
- set of flow direction and circuit identification labels;
- wall anchors.
Outlet connections with mechanical seal for 112 series balancing valves and 871 series ball valves. Connection: G 1 1/4" (ISO 228-1) F. Outlet connection: 42 p.2,5 TR, 7 outlets. Maximum working pressure: 6 bar. Maximum hydraulic test pressure: 10 bar. Medium temperature range: -10–60 °C. Ambient temperature range: -20–60 °C. Maximum percentage of glycol: 50 %. Medium: glycol solutions. Maximum recommended flow rate: 7 m³/h. DN: DN 50 (body).
SCIP code
b446b73a-f172-4281-a597-2a07d6a56648
|
|||
1107H5 | G 1 1/4" (ISO 228-1) F |
42 p.2,5 TR 8 outlets |
|
3D models
Tender text
Preassembled geothermal manifold. Complete with:
- automatic air vent;
- Ø80 mm temperature gauges;
- filler/drain cocks;
- composite flow and return manifolds;
- end fitting caps with insulation;
- stainless steel wall mounting brackets;
- set of flow direction and circuit identification labels;
- wall anchors.
Outlet connections with mechanical seal for 112 series balancing valves and 871 series ball valves. Connection: G 1 1/4" (ISO 228-1) F. Outlet connection: 42 p.2,5 TR, 8 outlets. Maximum working pressure: 6 bar. Maximum hydraulic test pressure: 10 bar. Medium temperature range: -10–60 °C. Ambient temperature range: -20–60 °C. Maximum percentage of glycol: 50 %. Medium: water. Maximum recommended flow rate: 7 m³/h. DN: DN 50 (body).
SCIP code
55deb742-f706-42f5-bfcc-9c75d612b6f8
|