Motorised regulating unit DN 32, for heating and cooling systems.
Product Description
Motorised regulating unit DN 32, for heating and cooling systems.
Available with three-point control signal actuator (note A) or 0(2)–10V control signal and 0–10V feedback signal (note B).
Regulation with three-way sector valve.
Right - left swappable.
With insulation.
Technical data
Maximum working pressure:
10 bar
Medium temperature range:
5–100 °C
Main centre distance:
125 mm
Type of pump:
Para 25-9
Note
Note A: three-point control signal actuator.
Operating time: 150 s.
Can be combined with regulators code 161010 and 1520 series.
Note B: 0(2)–10 V control signal actuator.
Feedback signal: 0–10 V.
Operating time: 75 s.
Can be combined with regulator code 161010 (for actuator electic supply use 230V / 24V transformer).
Certifications
Download
Drawings and specifications
Part number | System side connection | Boiler side connection | Electric supply |
---|---|---|---|
167662HE4 | G 1 1/4" (ISO 228-1) F |
G 1 1/2" A (ISO 228-1) M |
230 V AC |
Flow rate with available head 4 m.c.a.
2,2 m³/h
|
|||
2D drawings
3D models
Tender text
Motorised regulating unit DN 32, for heating and cooling systems.
With insulation.
With auxiliary microswitch.
Available with three-point control signal actuator (note A) or 0(2)–10V control signal and 0–10V feedback signal (note B).
Regulation with three-way sector valve.
Right - left swappable. System side connection: G 1 1/4" (ISO 228-1) F. Boiler side connection: G 1 1/2" A (ISO 228-1) M. Maximum working pressure: 10 bar. Medium temperature range: 5–100 °C. Electric supply: 230 V AC. Main centre distance: 125 mm. Flow rate with available head 4 m.c.a.: 2,2 m³/h. Type of pump: Para 25-9.
SCIP code
375fe02e-d029-4738-a96c-7828eac8c7d7
|
|||
167664HE4 | G 1 1/4" (ISO 228-1) F |
G 1 1/2" A (ISO 228-1) M |
24 V AC |
Flow rate with available head 4 m.c.a.
2,2 m³/h
|
|||
2D drawings
3D models
Tender text
Motorised regulating unit DN 32, for heating and cooling systems.
With insulation.
With auxiliary microswitch.
Available with three-point control signal actuator (note A) or 0(2)–10V control signal and 0–10V feedback signal (note B).
Regulation with three-way sector valve.
Right - left swappable. System side connection: G 1 1/4" (ISO 228-1) F. Boiler side connection: G 1 1/2" A (ISO 228-1) M. Maximum working pressure: 10 bar. Medium temperature range: 5–100 °C. Electric supply: 24 V AC. Main centre distance: 125 mm. Flow rate with available head 4 m.c.a.: 2,2 m³/h. Type of pump: Para 25-9.
SCIP code
e14c9fcb-10ce-4ca0-99e5-c101423be3e1
|