Hydraulic separator.
Product Description
Hydraulic separator.
Temperature probe connection: 1/2" F.
To be coupled with flat counterflanges EN 1092-1.
Complete with:
- automatic air vent;
- shut-off valve;
- drain valve.
With insulation.
Technical data
Maximum working pressure:
10 bar
Finish:
coated
Material:
steel
Note
The hydraulic separator should be sized according to the maximum flow rate value at the inlet. The selected design value must be the greatest between the primary circuit and the secondary circuit.
Download
Drawings and specifications
Part number | Connection | Medium temperature range | Maximum recommended flow rate |
---|---|---|---|
548052 | DN 50 (EN 1092-1) PN 16 |
0–105 °C | 9 m³/h |
3D models
Tender text
Hydraulic separator. With insulation.
Temperature probe connection: 1/2" F.
To be coupled with flat counterflanges EN 1092-1.
Complete with:
- automatic air vent;
- shut-off valve;
- drain valve.
Connection: DN 50 (EN 1092-1) PN 16. Maximum working pressure: 10 bar. Medium temperature range: 0–105 °C. Finish: coated. Maximum recommended flow rate: 9 m³/h. Material: steel.
SCIP code
bd12e2bf-4a5e-4d6b-b815-31f1c65211c3
|
|||
548062 | DN 65 (EN 1092-1) PN 16 |
0–105 °C | 18 m³/h |
3D models
Tender text
Hydraulic separator. With insulation.
Temperature probe connection: 1/2" F.
To be coupled with flat counterflanges EN 1092-1.
Complete with:
- automatic air vent;
- shut-off valve;
- drain valve.
Connection: DN 65 (EN 1092-1) PN 16. Maximum working pressure: 10 bar. Medium temperature range: 0–105 °C. Finish: coated. Maximum recommended flow rate: 18 m³/h. Material: steel.
SCIP code
a2ad2fd7-694c-40a4-8e5c-2f154df8b726
|
|||
548082 | DN 80 (EN 1092-1) PN 16 |
0–105 °C | 28 m³/h |
2D drawings
3D models
Tender text
Hydraulic separator. With insulation.
Temperature probe connection: 1/2" F.
To be coupled with flat counterflanges EN 1092-1.
Complete with:
- automatic air vent;
- shut-off valve;
- drain valve.
Connection: DN 80 (EN 1092-1) PN 16. Maximum working pressure: 10 bar. Medium temperature range: 0–105 °C. Finish: coated. Maximum recommended flow rate: 28 m³/h. Material: steel.
SCIP code
8313686b-3dfc-4f95-b5f5-8320d23d4a7b
|
|||
548102 | DN 100 (EN 1092-1) PN 16 |
0–105 °C | 56 m³/h |
2D drawings
3D models
Tender text
Hydraulic separator. With insulation.
Temperature probe connection: 1/2" F.
To be coupled with flat counterflanges EN 1092-1.
Complete with:
- automatic air vent;
- shut-off valve;
- drain valve.
Connection: DN 100 (EN 1092-1) PN 16. Maximum working pressure: 10 bar. Medium temperature range: 0–105 °C. Finish: coated. Maximum recommended flow rate: 56 m³/h. Material: steel.
SCIP code
76837b9e-dbda-4040-b8de-8ae4fe75f333
|
|||
548122 | DN 125 (EN 1092-1) PN 16 |
0–100 °C | 75 m³/h |
3D models
Tender text
Hydraulic separator. With insulation.
Temperature probe connection: 1/2" F.
To be coupled with flat counterflanges EN 1092-1.
Complete with:
- automatic air vent;
- shut-off valve;
- drain valve.
Connection: DN 125 (EN 1092-1) PN 16. Maximum working pressure: 10 bar. Medium temperature range: 0–100 °C. Finish: coated. Maximum recommended flow rate: 75 m³/h. Material: steel.
SCIP code
f1296f19-f149-42a9-b860-134ab2158884
|
|||
548152 | DN 150 (EN 1092-1) PN 16 |
0–100 °C | 110 m³/h |
3D models
Tender text
Hydraulic separator. With insulation.
Temperature probe connection: 1/2" F.
To be coupled with flat counterflanges EN 1092-1.
Complete with:
- automatic air vent;
- shut-off valve;
- drain valve.
Connection: DN 150 (EN 1092-1) PN 16. Maximum working pressure: 10 bar. Medium temperature range: 0–100 °C. Finish: coated. Maximum recommended flow rate: 110 m³/h. Material: steel.
SCIP code
45414492-95e2-4b02-ac8d-78505ac4bd4c
|