Series 850

Gas pressure closing filter regulator, double diaphragm. Threaded connections.

850006.png
Download high resolution

Product Description

Gas pressure closing filter regulator, double diaphragm. Threaded connections.
Filtering capacity: Ø ≥ 50 µm.
Regulation and closing at null flow according to UNI EN 88.
Compliance with directive ATEX (II 2G - II 2D).

Technical data

Gas filtration class: G2 (according to EN 779)
Medium temperature range: -15–60 °C
Maximum upstream pressure: 500 mbar

Certifications

ATEX
CE

Drawings and specifications

Part number Connection Adjustment pressure range Actions
850004 Rp 1/2" (EN 10226-1) F
18–40 mbar
3D models
Download
Download
Tender text
CALEFFI, 850004. Gas pressure closing filter regulator, double diaphragm. Threaded connections. Filtering capacity: Ø ≥ 50 µm. Regulation and closing at null flow according to UNI EN 88. Compliance with directive ATEX (II 2G - II 2D). Connection: Rp 1/2" (EN 10226-1) F. Maximum upstream pressure: 500 mbar. Medium temperature range: -15–60 °C. Adjustment pressure range: 18–40 mbar. Gas filtration class: G2 (according to EN 779).
SCIP code
3675bfb8-8677-4ea7-bb72-f94ab1329546
850005 Rp 3/4" (EN 10226-1) F
18–40 mbar
3D models
Download
Tender text
CALEFFI, 850005. Gas pressure closing filter regulator, double diaphragm. Threaded connections. Filtering capacity: Ø ≥ 50 µm. Regulation and closing at null flow according to UNI EN 88. Compliance with directive ATEX (II 2G - II 2D). Connection: Rp 3/4" (EN 10226-1) F. Maximum upstream pressure: 500 mbar. Medium temperature range: -15–60 °C. Adjustment pressure range: 18–40 mbar. Gas filtration class: G2 (according to EN 779).
SCIP code
3675bfb8-8677-4ea7-bb72-f94ab1329546
850006 Rp 1" (EN 10226-1) F
18–40 mbar
3D models
Download
Download
Tender text
CALEFFI, 850006. Gas pressure closing filter regulator, double diaphragm. Threaded connections. Filtering capacity: Ø ≥ 50 µm. Regulation and closing at null flow according to UNI EN 88. Compliance with directive ATEX (II 2G - II 2D). Connection: Rp 1" (EN 10226-1) F. Maximum upstream pressure: 500 mbar. Medium temperature range: -15–60 °C. Adjustment pressure range: 18–40 mbar. Gas filtration class: G2 (according to EN 779).
SCIP code
3675bfb8-8677-4ea7-bb72-f94ab1329546
850007 Rp 1 1/4" (EN 10226-1) F
13–23 mbar
3D models
Download
Download
Tender text
CALEFFI, 850007. Gas pressure closing filter regulator, double diaphragm. Threaded connections. Filtering capacity: Ø ≥ 50 µm. Regulation and closing at null flow according to UNI EN 88. Compliance with directive ATEX (II 2G - II 2D). Connection: Rp 1 1/4" (EN 10226-1) F. Maximum upstream pressure: 500 mbar. Medium temperature range: -15–60 °C. Adjustment pressure range: 13–23 mbar. Gas filtration class: G2 (according to EN 779).
SCIP code
3675bfb8-8677-4ea7-bb72-f94ab1329546
850008 Rp 1 1/2" (EN 10226-1) F
13–23 mbar
3D models
Download
Download
Tender text
CALEFFI, 850008. Gas pressure closing filter regulator, double diaphragm. Threaded connections. Filtering capacity: Ø ≥ 50 µm. Regulation and closing at null flow according to UNI EN 88. Compliance with directive ATEX (II 2G - II 2D). Connection: Rp 1 1/2" (EN 10226-1) F. Maximum upstream pressure: 500 mbar. Medium temperature range: -15–60 °C. Adjustment pressure range: 13–23 mbar. Gas filtration class: G2 (according to EN 779).
SCIP code
3675bfb8-8677-4ea7-bb72-f94ab1329546
850009 Rp 2" (EN 10226-1) F
13–23 mbar
3D models
Download
Download
Tender text
CALEFFI, 850009. Gas pressure closing filter regulator, double diaphragm. Threaded connections. Filtering capacity: Ø ≥ 50 µm. Regulation and closing at null flow according to UNI EN 88. Compliance with directive ATEX (II 2G - II 2D). Connection: Rp 2" (EN 10226-1) F. Maximum upstream pressure: 500 mbar. Medium temperature range: -15–60 °C. Adjustment pressure range: 13–23 mbar. Gas filtration class: G2 (according to EN 779).
SCIP code
3675bfb8-8677-4ea7-bb72-f94ab1329546

Applications

Pipe Sizer Caleffi
Pipe Sizer Caleffi

This application allows for sizing and making calculations for pipes and conduits carrying water or air, respectively for hydraulic or aeraulic plants.