Series 6000

LEGIOMIX®, Electronic mixing valve with programmable thermal disinfection and check on disinfection, 230 V. Male threaded connections with union.

Go to
600051.png
600051_dim~-~page-1.png
600051_sez~-~page-1.png
600051.png
600051_dim~-~page-1.png
600051_sez~-~page-1.png
Download high resolution

Product Description

Electronic mixing valve with programmable thermal disinfection and check on disinfection, 230 V. Male threaded connections with union.
Complete with:
- 3-way ball valve;
- actuator;
- regulator;
- flow temperature prob;
- return temperature probe.
With auxiliary microswitch.
PATENT

Technical data

Maximum working pressure: 10 bar
Medium temperature range: 0–100 °C
Adjustment temperature range: 20–85 °C
Disinfection temperature range: 40–85 °C
Electric supply: 230 V (AC)
Power consumption: (6,5+6) VA
Protection class: IP 65

Certifications

CE
HY-CERT
ACS
PZH

Drawings and specifications

Part number Connection Connection Kv
2D drawings
Download
Download
3D models
Download
Tender text
Electronic mixing valve with programmable thermal disinfection and check on disinfection, 230 V. Male threaded connections with union. With auxiliary microswitch. Complete with: - 3-way ball valve; - actuator; - regulator; - flow temperature prob; - return temperature probe. connection: R 3/4" (EN 10226-1) M, inlet, union. connection: G 3/4" (ISO 228-1) F, end outlet. Maximum working pressure: 10 bar. Medium temperature range: 0–100 °C. Adjustment temperature range: 20–85 °C. Disinfection temperature range: 40–85 °C. Electric supply: 230 V (AC). Power consumption: (6,5+6) VA. Protection class: IP 65. Kv: 8,4 m³/h.
2D drawings
Download
Download
3D models
Download
Download
Tender text
Electronic mixing valve with programmable thermal disinfection and check on disinfection, 230 V. Male threaded connections with union. With auxiliary microswitch. Complete with: - 3-way ball valve; - actuator; - regulator; - flow temperature prob; - return temperature probe. connection: R 1" (EN 10226-1) M, inlet, union. connection: G 1" (ISO 228-1) F, end outlet. Maximum working pressure: 10 bar. Medium temperature range: 0–100 °C. Adjustment temperature range: 20–85 °C. Disinfection temperature range: 40–85 °C. Electric supply: 230 V (AC). Power consumption: (6,5+6) VA. Protection class: IP 65. Kv: 10,6 m³/h.
2D drawings
Download
Download
3D models
Download
Tender text
Electronic mixing valve with programmable thermal disinfection and check on disinfection, 230 V. Male threaded connections with union. With auxiliary microswitch. Complete with: - 3-way ball valve; - actuator; - regulator; - flow temperature prob; - return temperature probe. connection: R 1 1/4" (EN 10226-1) M, inlet, union. connection: G 1 1/4" (ISO 228-1) F, end outlet. Maximum working pressure: 10 bar. Medium temperature range: 0–100 °C. Adjustment temperature range: 20–85 °C. Disinfection temperature range: 40–85 °C. Electric supply: 230 V (AC). Power consumption: (6,5+6) VA. Protection class: IP 65. Kv: 21,2 m³/h.
2D drawings
Download
Download
3D models
Download
Download
Tender text
Electronic mixing valve with programmable thermal disinfection and check on disinfection, 230 V. Male threaded connections with union. With auxiliary microswitch. Complete with: - 3-way ball valve; - actuator; - regulator; - flow temperature prob; - return temperature probe. connection: R 1 1/2" (EN 10226-1) M, inlet, union. connection: G 1 1/2" (ISO 228-1) F, end outlet. Maximum working pressure: 10 bar. Medium temperature range: 0–100 °C. Adjustment temperature range: 20–85 °C. Disinfection temperature range: 40–85 °C. Electric supply: 230 V (AC). Power consumption: (6,5+6) VA. Protection class: IP 65. Kv: 32,5 m³/h.
2D drawings
Download
Download
3D models
Download
Download
Tender text
Electronic mixing valve with programmable thermal disinfection and check on disinfection, 230 V. Male threaded connections with union. With auxiliary microswitch. Complete with: - 3-way ball valve; - actuator; - regulator; - flow temperature prob; - return temperature probe. connection: R 2" (EN 10226-1) M, inlet, union. connection: G 2" (ISO 228-1) F, end outlet. Maximum working pressure: 10 bar. Medium temperature range: 0–100 °C. Adjustment temperature range: 20–85 °C. Disinfection temperature range: 40–85 °C. Electric supply: 230 V (AC). Power consumption: (6,5+6) VA. Protection class: IP 65. Kv: 41,0 m³/h.

Applications

Pipe Sizer Caleffi
Pipe Sizer Caleffi

This application allows for sizing and making calculations for pipes and conduits carrying water or air, respectively for hydraulic or aeraulic plants.

DWS

Caleffi Domestic Water Sizer allows fast and correct sizing of the main components of domestic water systems.

Scroll