Series 7941

Template for domestic water meter.

Go to
794140.png
794140_dim~-~page-1.png
794140.png
794140_dim~-~page-1.png
Download high resolution

Product Description

Template for domestic water meter.
Complete with:
- ball shut-off valve with built-in check valve BALLSTOP;
- flow meter with pulse output;
- shut-off ball valve (outlet);
- fixing collars.

Technical data

Nominal pressure: PN 16
Medium: domestic water
Pulse weight: 10 l/pulse

Certifications

MI001
ACS

Drawings and specifications

Part number Inlet connection Outlet connection Note
Medium temperature range
0–50 °C
Permanent flow rate (Domestic water circuit) (Q3)
2,5 m³/h
2D drawings
Download
Download
3D models
Tender text
Template for domestic water meter. Complete with: - ball shut-off valve with built-in check valve BALLSTOP; - flow meter with pulse output; - shut-off ball valve (outlet); - fixing collars. Inlet connection: G 1/2" (ISO 228-1) F. Outlet connection: G 1/2" A (ISO 228-1) M. Medium temperature range: 0–50 °C. Nominal pressure: PN 16. Medium: domestic water. Permanent flow rate (Domestic water circuit) (Q3): 2,5 m³/h. Permanent flow rate (Qp): . Pulse weight: 10 l/pulse.
SCIP code
906c1bb0-fc2a-4cba-ad1a-500c1d60c87a
Medium temperature range
30–90 °C
Permanent flow rate (Domestic water circuit) (Q3)
2,5 m³/h
2D drawings
Download
Download
3D models
Tender text
Template for domestic water meter. Complete with: - ball shut-off valve with built-in check valve BALLSTOP; - flow meter with pulse output; - shut-off ball valve (outlet); - fixing collars. Inlet connection: G 1/2" (ISO 228-1) F. Outlet connection: G 1/2" A (ISO 228-1) M. Medium temperature range: 30–90 °C. Nominal pressure: PN 16. Medium: domestic water. Permanent flow rate (Domestic water circuit) (Q3): 2,5 m³/h. Permanent flow rate (Qp): . Pulse weight: 10 l/pulse.
SCIP code
3cca919f-db4b-4d12-8a7c-a8e2c3f596fe
Medium temperature range
0–50 °C
Permanent flow rate (Domestic water circuit) (Q3)
4,0 m³/h
2D drawings
Download
Download
3D models
Tender text
Template for domestic water meter. Complete with: - ball shut-off valve with built-in check valve BALLSTOP; - flow meter with pulse output; - shut-off ball valve (outlet); - fixing collars. Inlet connection: G 3/4" (ISO 228-1) F. Outlet connection: G 3/4" A (ISO 228-1) M. Medium temperature range: 0–50 °C. Nominal pressure: PN 16. Medium: domestic water. Permanent flow rate (Domestic water circuit) (Q3): 4,0 m³/h. Permanent flow rate (Qp): . Pulse weight: 10 l/pulse.
SCIP code
452728fe-a7c9-48be-bac7-7069810452f0
Medium temperature range
30–90 °C
Permanent flow rate (Domestic water circuit) (Q3)
4,0 m³/h
2D drawings
Download
Download
3D models
Tender text
Template for domestic water meter. Complete with: - ball shut-off valve with built-in check valve BALLSTOP; - flow meter with pulse output; - shut-off ball valve (outlet); - fixing collars. Inlet connection: G 3/4" (ISO 228-1) F. Outlet connection: G 3/4" A (ISO 228-1) M. Medium temperature range: 30–90 °C. Nominal pressure: PN 16. Medium: domestic water. Permanent flow rate (Domestic water circuit) (Q3): 4,0 m³/h. Permanent flow rate (Qp): . Pulse weight: 10 l/pulse.
SCIP code
c4d90371-cae0-4382-8f4e-d1eb416b5ec5

Applications

DWS

Caleffi Domestic Water Sizer allows fast and correct sizing of the main components of domestic water systems.