Series 7507

CONTECA EASY ULTRA, Direct ultrasonic heat meter for zone systems and central heating systems.

Go to
750704.png
750704_dim~-~page-1.png
750704_app~-~page-1.png
750704.png
750704_dim~-~page-1.png
750704_app~-~page-1.png
Download high resolution

Product Description

Direct ultrasonic heat meter for zone systems and central heating systems.
The metering module is supplied complete with:
- pair of immersion temperature probes (L= 1,9 m);
- pair of Y pockets;
- Ultrasound measuring device;
- electronic integrator with LCD display.
Local reading via LCD display/centralised reading via BUS transmission.
Strainer mesh located in flow pocket.

Technical data

Medium temperature range: 2–90 °C
Electric supply: 24 V (AC)
Power consumption: 1 W
PN (Nominal pressure): PN 16
Accuracy class: 2

Certifications

CE
MI004

Drawings and specifications

Part number Connection Note Permanent flow rate (Qp)
Minimum flow rate (Qi)
10 l/h
2D drawings
Download
Download
3D models
Download
Download
Tender text
Direct ultrasonic heat meter for zone systems and central heating systems. The metering module is supplied complete with: - pair of immersion temperature probes (L= 1,9 m); - pair of Y pockets; - Ultrasound measuring device; - electronic integrator with LCD display. Local reading via LCD display/centralised reading via BUS transmission. Strainer mesh located in flow pocket. Connection: G 3/4" A (ISO 228-1) M, union. Medium temperature range: 2–90 °C. Electric supply: 24 V (AC). Power consumption: 1 W. PN (Nominal pressure): PN 16. Accuracy class: 2. Permanent flow rate (Qp): 2,5 m³/h. Minimum flow rate (Qi): 10 l/h.
SCIP code
9e1bc076-97f0-4a31-98d4-b124b1b252c8
Minimum flow rate (Qi)
35 l/h
2D drawings
Download
Download
3D models
Download
Download
Tender text
Direct ultrasonic heat meter for zone systems and central heating systems. The metering module is supplied complete with: - pair of immersion temperature probes (L= 1,9 m); - pair of Y pockets; - Ultrasound measuring device; - electronic integrator with LCD display. Local reading via LCD display/centralised reading via BUS transmission. Strainer mesh located in flow pocket. Connection: G 1" A (ISO 228-1) M, union. Medium temperature range: 2–90 °C. Electric supply: 24 V (AC). Power consumption: 1 W. PN (Nominal pressure): PN 16. Accuracy class: 2. Permanent flow rate (Qp): 3,5 m³/h. Minimum flow rate (Qi): 35 l/h.
SCIP code
1e960c85-a71e-4e62-af6e-3daf525350de
Minimum flow rate (Qi)
24 l/h
2D drawings
Download
Download
3D models
Download
Download
Tender text
Direct ultrasonic heat meter for zone systems and central heating systems. The metering module is supplied complete with: - pair of immersion temperature probes (L= 1,9 m); - pair of Y pockets; - Ultrasound measuring device; - electronic integrator with LCD display. Local reading via LCD display/centralised reading via BUS transmission. Strainer mesh located in flow pocket. Connection: G 1 1/4" A (ISO 228-1) M, union. Medium temperature range: 2–90 °C. Electric supply: 24 V (AC). Power consumption: 1 W. PN (Nominal pressure): PN 16. Accuracy class: 2. Permanent flow rate (Qp): 6 m³/h. Minimum flow rate (Qi): 24 l/h.
SCIP code
4807cc06-544d-420c-9c21-265b8be20208