Technical data
Medium temperature range:
5–65 °C
Nominal pressure:
PN 10
Material:
dezincification resistant brass DR
Certifications
![ACS ACS](/sites/default/files/certifications/ACS.png)
![BELGAQUA BELGAQUA](/sites/default/files/certifications/BELGAQUA.png)
![DVGW DIN CERT DVGW DIN CERT](/sites/default/files/certifications/DVGW%2520DIN%2520CERT.png)
![KIWA KIWA](/sites/default/files/certifications/KIWA.png)
![NF NF](/sites/default/files/certifications/NF.png)
![SVGW SVGW](/sites/default/files/certifications/SVGW.png)
![HY-CERT HY-CERT](/sites/default/files/certifications/HY-CERT.png)
![PZH PZH](/sites/default/files/certifications/NIZP%2520ATEST%2520PIB.png)
Download
Drawings and specifications
Part number | Inlet Connection | Outlet connection | DN |
---|---|---|---|
580104 | G 3/4" (ISO 228-1) F captive nut |
G 3/4" A (ISO 228-1) M |
DN 15 (body) |
2D drawings
3D models
Tender text
Backflow preventer with multifunction geometry. BA type. Complete with connection fitting to the tap at the inlet and hose connection at the outlet.
Complete with strainer at the inlet.
For vertical installation. Certified to EN 12729 and
Beschluss 4/2007 standard. Inlet Connection: G 3/4" (ISO 228-1) F, captive nut. Outlet connection: G 3/4" A (ISO 228-1) M. Medium temperature range: 5–65 °C. Nominal pressure: PN 10. DN: DN 15 (body). Material: dezincification resistant brass DR.
SCIP code
d1f4f8e7-b897-44cc-8ad9-7b876117c321
|
|||
580150 | G 3/4" (ISO 228-1) F captive nut |
G 3/4" A (ISO 228-1) M |
DN 20 (body) |
2D drawings
3D models
Tender text
Backflow preventer with multifunction geometry. BA type. Complete with connection fitting to the tap at the inlet and hose connection at the outlet.
Complete with strainer at the inlet.
For vertical installation. Certified to EN 12729 and
Beschluss 4/2007 standard. Inlet Connection: G 3/4" (ISO 228-1) F, captive nut. Outlet connection: G 3/4" A (ISO 228-1) M. Medium temperature range: 5–65 °C. Nominal pressure: PN 10. DN: DN 20 (body). Material: dezincification resistant brass DR.
SCIP code
16725443-0b86-4f33-b192-010715f383b5
|