Series 140

Differential pressure control valve (DPCV).

Go to
140340.png
140340_sez~-~page-1.png
140340_dim~-~page-1.png
140340.png
140340_sez~-~page-1.png
140340_dim~-~page-1.png
Download high resolution

Product Description

Differential pressure control valve (DPCV).
Complete with capillary connection pipe to the valve on the flow pipe.
With insulation.

Technical data

Medium temperature range: -10–120 °C
Capillary length: 1,5 m
Maximum percentage of glycol: 50 %
Medium: water, glycol solutions
Material: dezincification resistant brass DR

Drawings and specifications

Part number Connection Note Maximum working pressure
△p setting
50–300 mbar
2D drawings
Download
Download
3D models
Download
Download
Tender text
Differential pressure control valve (DPCV). With insulation. Complete with capillary connection pipe to the valve on the flow pipe. Connection: G 1/2" (ISO 228-1) F. Maximum working pressure: 16 bar. Medium temperature range: -10–120 °C. △p setting: 50–300 mbar. Capillary length: 1,5 m. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions. Material: dezincification resistant brass DR.
SCIP code
52818d38-ce74-482c-beee-0920c2362e4e
△p setting
250–600 mbar
2D drawings
Download
Download
3D models
Download
Download
Tender text
Differential pressure control valve (DPCV). With insulation. Complete with capillary connection pipe to the valve on the flow pipe. Connection: G 1/2" (ISO 228-1) F. Maximum working pressure: 16 bar. Medium temperature range: -10–120 °C. △p setting: 250–600 mbar. Capillary length: 1,5 m. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions. Material: dezincification resistant brass DR.
SCIP code
f0dabdcd-9ce4-428a-8523-10bbb59d1a2f
△p setting
50–300 mbar
2D drawings
Download
Download
3D models
Download
Download
Tender text
Differential pressure control valve (DPCV). With insulation. Complete with capillary connection pipe to the valve on the flow pipe. Connection: G 3/4" (ISO 228-1) F. Maximum working pressure: 16 bar. Medium temperature range: -10–120 °C. △p setting: 50–300 mbar. Capillary length: 1,5 m. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions. Material: dezincification resistant brass DR.
SCIP code
6c30d4f0-76fe-4229-9308-c57cf6d53804
△p setting
250–600 mbar
2D drawings
Download
Download
3D models
Download
Download
Tender text
Differential pressure control valve (DPCV). With insulation. Complete with capillary connection pipe to the valve on the flow pipe. Connection: G 3/4" (ISO 228-1) F. Maximum working pressure: 16 bar. Medium temperature range: -10–120 °C. △p setting: 250–600 mbar. Capillary length: 1,5 m. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions. Material: dezincification resistant brass DR.
SCIP code
16c390e7-077f-4482-8d81-0693dce4da9c
△p setting
50–300 mbar
2D drawings
Download
Download
3D models
Tender text
Differential pressure control valve (DPCV). With insulation. Complete with capillary connection pipe to the valve on the flow pipe. Connection: G 1" (ISO 228-1) F. Maximum working pressure: 16 bar. Medium temperature range: -10–120 °C. △p setting: 50–300 mbar. Capillary length: 1,5 m. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions. Material: dezincification resistant brass DR.
SCIP code
90b062c1-442f-47df-a8f9-e30445d87f51
△p setting
250–600 mbar
2D drawings
Download
Download
3D models
Tender text
Differential pressure control valve (DPCV). With insulation. Complete with capillary connection pipe to the valve on the flow pipe. Connection: G 1" (ISO 228-1) F. Maximum working pressure: 16 bar. Medium temperature range: -10–120 °C. △p setting: 250–600 mbar. Capillary length: 1,5 m. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions. Material: dezincification resistant brass DR.
SCIP code
462a8f84-d277-4882-b6cf-9c9961e4434d
△p setting
50–300 mbar
2D drawings
Download
Download
3D models
Download
Download
Tender text
Differential pressure control valve (DPCV). Complete with capillary connection pipe to the valve on the flow pipe. Connection: G 1/2" (ISO 228-1) F. Maximum working pressure: 16 bar. Medium temperature range: -10–120 °C. △p setting: 50–300 mbar. Capillary length: 1,5 m. Maximum percentage of glycol: 50 %. Medium: glycol solutions, water. Material: dezincification resistant brass DR.
SCIP code
36ddd24c-b4b5-4ffd-8451-c901402a29d7
△p setting
250–600 mbar
3D models
Tender text
Differential pressure control valve (DPCV). Complete with capillary connection pipe to the valve on the flow pipe. Connection: G 1/2" (ISO 228-1) F. Maximum working pressure: 16 bar. Medium temperature range: -10–120 °C. △p setting: 250–600 mbar. Capillary length: 1,5 m. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions. Material: dezincification resistant brass DR.
SCIP code
5c63a2c5-ab70-4391-b992-a3c2161116a9
△p setting
50–300 mbar
2D drawings
Download
Download
3D models
Download
Download
Tender text
Differential pressure control valve (DPCV). Complete with capillary connection pipe to the valve on the flow pipe. Connection: G 3/4" (ISO 228-1) F. Maximum working pressure: 16 bar. Medium temperature range: -10–120 °C. △p setting: 50–300 mbar. Capillary length: 1,5 m. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions. Material: dezincification resistant brass DR.
SCIP code
c50f635b-08cc-432d-b2d5-6b4fa20ae8f3
△p setting
250–600 mbar
3D models
Tender text
Differential pressure control valve (DPCV). Complete with capillary connection pipe to the valve on the flow pipe. Connection: G 3/4" (ISO 228-1) F. Maximum working pressure: 16 bar. Medium temperature range: -10–120 °C. △p setting: 250–600 mbar. Capillary length: 1,5 m. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions. Material: dezincification resistant brass DR.
SCIP code
383e9560-dce5-4d00-8df3-9bb4419e909d
△p setting
50–300 mbar
3D models
Tender text
Differential pressure control valve (DPCV). Complete with capillary connection pipe to the valve on the flow pipe. Connection: G 1" (ISO 228-1) F. Maximum working pressure: 16 bar. Medium temperature range: -10–120 °C. △p setting: 50–300 mbar. Capillary length: 1,5 m. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions. Material: dezincification resistant brass DR.
SCIP code
480cbfab-d48a-4c5f-8128-157859ead42f
△p setting
250–600 mbar
2D drawings
Download
Download
3D models
Download
Download
Tender text
Differential pressure control valve (DPCV). Complete with capillary connection pipe to the valve on the flow pipe. Connection: G 1" (ISO 228-1) F. Maximum working pressure: 16 bar. Medium temperature range: -10–120 °C. △p setting: 250–600 mbar. Capillary length: 1,5 m. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions. Material: dezincification resistant brass DR.
SCIP code
79a29f91-bdb7-4f61-ac23-055337606eba

Applications

Pipe Sizer Caleffi
Pipe Sizer Caleffi

This application allows for sizing and making calculations for pipes and conduits carrying water or air, respectively for hydraulic or aeraulic plants.