LEGIOFLOW®, Multi-function compact unit for temperature control, thermal disinfection and distribution for domestic water system. Version without cold water circuit outlet kit.
Product Description
Multi-function compact unit for temperature control, thermal disinfection and distribution for domestic water system. Version without cold water circuit outlet kit.
Complete with:
- anti-scald thermostatic mixing valve;
- flushing valve for thermal disinfection complete with thermo-electric actuator;
- ball shut-off valve with built-in strainers and check valves;
- outlet kit for cold water circuit.
Normally closed thermo-electric actuator.
For applications with button- or photocell-operated user taps.
Performance according to the NF 079 doc. 8, EN 1111 and EN 1287 standards.
PATENT
Technical data
Maximum working pressure:
10 bar
Medium temperature range:
5–85 °C
Adjustment temperature range:
30–50 °C
Setting:
43 °C
Electric supply:
230 V (AC)
Power consumption:
3 W
Protection class:
IP 44
Supply cable length:
0,8 m
Material:
dezincification resistant brass DR
Certifications


Download
Application diagrams
Drawings and specifications
Part number | Connection | Note | Kv mixing valve |
---|---|---|---|
600502 | G 3/4" A (ISO 228-1) M |
With thermo-electric actuator | 1,75 m³/h |
Kv flushing valve
1,80 m³/h
|
|||
3D models
Tender text
Multi-function compact unit for temperature control, thermal disinfection and distribution for domestic water system. Version without cold water circuit outlet kit.
Complete with:
- anti-scald thermostatic mixing valve;
- flushing valve for thermal disinfection complete with thermo-electric actuator;
- ball shut-off valve with built-in strainers and check valves;
- outlet kit for cold water circuit.
Normally closed thermo-electric actuator.
For applications with button- or photocell-operated user taps. Performance according to the NF 079 doc. 8, EN 1111 and EN 1287 standards. connection: G 3/4" A (ISO 228-1) M. Maximum working pressure: 10 bar. Medium temperature range: 5–85 °C. Adjustment temperature range: 30–50 °C. Setting: 43 °C. Electric supply: 230 V (AC). Power consumption: 3 W. Protection class: IP 44. Supply cable length: 0,8 m. Kv mixing valve: 1,75 m³/h. Kv flushing valve: 1,80 m³/h. Material: dezincification resistant brass DR.
|
|||
600503 | G 3/4" A (ISO 228-1) M |
Without thermo-electric actuator | 1,75 m³/h |
Kv flushing valve
1,80 m³/h
|
|||
3D models
Tender text
Multi-function compact unit for temperature control, thermal disinfection and distribution for domestic water system. Version without cold water circuit outlet kit.
Complete with:
- anti-scald thermostatic mixing valve;
- flushing valve for thermal disinfection complete with thermo-electric actuator;
- ball shut-off valve with built-in strainers and check valves;
- outlet kit for cold water circuit.
Normally closed thermo-electric actuator.
For applications with button- or photocell-operated user taps. Performance according to the NF 079 doc. 8, EN 1111 and EN 1287 standards. connection: G 3/4" A (ISO 228-1) M. Maximum working pressure: 10 bar. Medium temperature range: 5–85 °C. Adjustment temperature range: 30–50 °C. Setting: 43 °C. Electric supply: 230 V (AC). Power consumption: 3 W. Protection class: IP 44. Supply cable length: 0,8 m. Kv mixing valve: 1,75 m³/h. Kv flushing valve: 1,80 m³/h. Material: dezincification resistant brass DR.
|