Series 6005

LEGIOFLOW®, Multi-function compact unit for temperature control, thermal disinfection and distribution for domestic water system. Version without cold water circuit outlet kit. 

Go to
600502.png
Download high resolution

Product Description

Multi-function compact unit for temperature control, thermal disinfection and distribution for domestic water system. Version without cold water circuit outlet kit. 
Complete with:
- anti-scald thermostatic mixing valve;
- flushing valve for thermal disinfection complete with thermo-electric actuator;
- ball shut-off valve with built-in strainers and check valves;
- outlet kit for cold water circuit.
Normally closed thermo-electric actuator.
For applications with button- or photocell-operated user taps.
Performance according to the NF 079 doc. 8, EN 1111 and EN 1287 standards.
PATENT

Technical data

Maximum working pressure: 10 bar
Medium temperature range: 5–85 °C
Adjustment temperature range: 30–50 °C
Setting: 43 °C
Electric supply: 230 V (AC)
Power consumption: 3 W
Protection class: IP 44
Supply cable length: 0,8 m
Material: dezincification resistant brass DR

Certifications

ACS
PZH

Drawings and specifications

Part number Connection Note Kv mixing valve
Kv flushing valve
1,80 m³/h
3D models
Tender text
Multi-function compact unit for temperature control, thermal disinfection and distribution for domestic water system. Version without cold water circuit outlet kit.  Complete with: - anti-scald thermostatic mixing valve; - flushing valve for thermal disinfection complete with thermo-electric actuator; - ball shut-off valve with built-in strainers and check valves; - outlet kit for cold water circuit. Normally closed thermo-electric actuator. For applications with button- or photocell-operated user taps. Performance according to the NF 079 doc. 8, EN 1111 and EN 1287 standards. connection: G 3/4" A (ISO 228-1) M. Maximum working pressure: 10 bar. Medium temperature range: 5–85 °C. Adjustment temperature range: 30–50 °C. Setting: 43 °C. Electric supply: 230 V (AC). Power consumption: 3 W. Protection class: IP 44. Supply cable length: 0,8 m. Kv mixing valve: 1,75 m³/h. Kv flushing valve: 1,80 m³/h. Material: dezincification resistant brass DR.
Kv flushing valve
1,80 m³/h
3D models
Tender text
Multi-function compact unit for temperature control, thermal disinfection and distribution for domestic water system. Version without cold water circuit outlet kit.  Complete with: - anti-scald thermostatic mixing valve; - flushing valve for thermal disinfection complete with thermo-electric actuator; - ball shut-off valve with built-in strainers and check valves; - outlet kit for cold water circuit. Normally closed thermo-electric actuator. For applications with button- or photocell-operated user taps. Performance according to the NF 079 doc. 8, EN 1111 and EN 1287 standards. connection: G 3/4" A (ISO 228-1) M. Maximum working pressure: 10 bar. Medium temperature range: 5–85 °C. Adjustment temperature range: 30–50 °C. Setting: 43 °C. Electric supply: 230 V (AC). Power consumption: 3 W. Protection class: IP 44. Supply cable length: 0,8 m. Kv mixing valve: 1,75 m³/h. Kv flushing valve: 1,80 m³/h. Material: dezincification resistant brass DR.

Applications

Pipe Sizer Caleffi
Pipe Sizer Caleffi

This application allows for sizing and making calculations for pipes and conduits carrying water or air, respectively for hydraulic or aeraulic plants.