Motorised three-way ball zone valve, by-pass version.
Product Description
Motorised three-way ball zone valve, by-pass version.
Complete with three-point control actuator.
Operating time 40s.
With auxiliary microswitch.
PATENT
Technical data
Maximum working pressure:
10 bar
Medium temperature range:
-5–110 °C
Ambient temperature range:
0–55 °C
Protection class:
IP 54
Supply cable length:
1 m
Auxiliary microswitch contact rating (230 V):
0,8 A
Operating time:
40 s
Rotation:
90° rotation
Certifications
Download
Drawings and specifications
Part number | Connection | Electric supply | Kv straight |
---|---|---|---|
644342 3BY | G 1/2" A (ISO 228-1) M |
230 V AC | 10,3 m³/h |
Kv by-pass
1,8 m³/h
|
|||
3D models
Tender text
Motorised three-way ball zone valve, by-pass version. With auxiliary microswitch.
Complete with motor with 3-contact control.
Connection: G 1/2" A (ISO 228-1) M. Maximum working pressure: 10 bar. Medium temperature range: -5–110 °C. Ambient temperature range: 0–55 °C. Electric supply: 230 V AC. Protection class: IP 54. Supply cable length: 1 m. Auxiliary microswitch contact rating (230 V): 0,8 A. Kv straight: 10,3 m³/h. Kv by-pass: 1,8 m³/h. Operating time: 40 s (90° rotation).
SCIP code
092f4928-7a9e-4d07-90ca-583c2b85de1a
|
|||
644352 3BY | G 3/4" A (ISO 228-1) M |
230 V AC | 10,3 m³/h |
Kv by-pass
1,8 m³/h
|
|||
3D models
Tender text
Motorised three-way ball zone valve, by-pass version. With auxiliary microswitch.
Complete with motor with 3-contact control.
Connection: G 3/4" A (ISO 228-1) M. Maximum working pressure: 10 bar. Medium temperature range: -5–110 °C. Ambient temperature range: 0–55 °C. Electric supply: 230 V AC. Protection class: IP 54. Supply cable length: 1 m. Auxiliary microswitch contact rating (230 V): 0,8 A. Kv straight: 10,3 m³/h. Kv by-pass: 1,8 m³/h. Operating time: 40 s (90° rotation).
SCIP code
b4ac2a08-21a4-439b-9d53-7ddc11b39e95
|
|||
644362 3BY | G 1" A (ISO 228-1) M |
230 V AC | 10,3 m³/h |
Kv by-pass
1,8 m³/h
|
|||
3D models
Tender text
Motorised three-way ball zone valve, by-pass version. With auxiliary microswitch.
Complete with motor with 3-contact control.
Connection: G 1" A (ISO 228-1) M. Maximum working pressure: 10 bar. Medium temperature range: -5–110 °C. Ambient temperature range: 0–55 °C. Electric supply: 230 V AC. Protection class: IP 54. Supply cable length: 1 m. Auxiliary microswitch contact rating (230 V): 0,8 A. Kv straight: 10,3 m³/h. Kv by-pass: 1,8 m³/h. Operating time: 40 s (90° rotation).
SCIP code
d9041ba7-f075-418f-9481-19df39f779bf
|
|||
644344 3BY | G 1/2" A (ISO 228-1) M |
24 V AC | 10,3 m³/h |
Kv by-pass
1,8 m³/h
|
|||
2D drawings
3D models
Tender text
Motorised three-way ball zone valve, by-pass version. With auxiliary microswitch.
Complete with motor with 3-contact control.
Connection: G 1/2" A (ISO 228-1) M. Maximum working pressure: 10 bar. Medium temperature range: -5–110 °C. Ambient temperature range: 0–55 °C. Electric supply: 24 V AC. Protection class: IP 54. Supply cable length: 1 m. Auxiliary microswitch contact rating (230 V): 0,8 A. Kv straight: 10,3 m³/h. Kv by-pass: 1,8 m³/h. Operating time: 40 s (90° rotation).
SCIP code
cdb3f596-0228-4ff5-9ac6-6c13f370696c
|
|||
644354 3BY | G 3/4" A (ISO 228-1) M |
24 V AC | 10,3 m³/h |
Kv by-pass
1,8 m³/h
|
|||
3D models
Tender text
Motorised three-way ball zone valve, by-pass version. With auxiliary microswitch.
Complete with motor with 3-contact control.
Connection: G 3/4" A (ISO 228-1) M. Maximum working pressure: 10 bar. Medium temperature range: -5–110 °C. Ambient temperature range: 0–55 °C. Electric supply: 24 V AC. Protection class: IP 54. Supply cable length: 1 m. Auxiliary microswitch contact rating (230 V): 0,8 A. Kv straight: 10,3 m³/h. Kv by-pass: 1,8 m³/h. Operating time: 40 s (90° rotation).
SCIP code
cda62dbd-6fc0-410e-a40e-2975754b35dc
|
|||
644364 3BY | G 1" A (ISO 228-1) M |
24 V AC | 10,3 m³/h |
Kv by-pass
1,8 m³/h
|
|||
3D models
Tender text
Motorised three-way ball zone valve, by-pass version. With auxiliary microswitch.
Complete with motor with 3-contact control.
Connection: G 1" A (ISO 228-1) M. Maximum working pressure: 10 bar. Medium temperature range: -5–110 °C. Ambient temperature range: 0–55 °C. Electric supply: 24 V AC. Protection class: IP 54. Supply cable length: 1 m. Auxiliary microswitch contact rating (230 V): 0,8 A. Kv straight: 10,3 m³/h. Kv by-pass: 1,8 m³/h. Operating time: 40 s (90° rotation).
SCIP code
cf11a512-c2e3-45f2-8d8c-63cc4e5dd9c9
|