Series 7504K

CONTECA EASY, Direct heat meter for heat interface units.

Go to
750405K.png
Download high resolution

Product Description

Direct heat meter for heat interface units.
Complete with:
- electronic integrator with LCD display;
- pair of immersion temperature probes;
- turbine volume meter with pulse output;
- mounting brackets;
- pulse input for DCW.
Upgradable with configuration options to be ordered together (*).

Technical data

Medium temperature range: 2–90 °C
Electric supply: 24 V AC
Running power consumption: 1 W
Protection class: IP 54
Probe/cable length: 1 m
Nominal pressure: PN 16
Accuracy class: 3
Communication protocol: M-Bus on RS485

Note

(*) Configuration options needs to be chosen when placing the order on heat meter in which they have to be enabled.

Certifications

CE
MI004

Drawings and specifications

Part number Connection Permanent flow rate (Qp) Measure type
2D drawings
Download
Download
3D models
Download
Download
Tender text
Direct heat meter for heat interface units. Complete with: - electronic integrator with LCD display; - pair of immersion temperature probes; - turbine volume meter with pulse output; - mounting brackets; - pulse input for DCW. Upgradable with configuration options to be ordered together (*). Connection: G 1" A (ISO 228-1) M. Medium temperature range: 2–90 °C. Electric supply: 24 V AC. Running power consumption: 1 W. Protection class: IP 54. Probe/cable length: 1 m. Nominal pressure: PN 16. Accuracy class: 3. Permanent flow rate (Qp): 2,5 m³/h. Communication protocol: M-Bus on RS485. Measure type: single nozzle.
SCIP code
74511593-a4dd-48e8-b8d0-09da1b831ade