Series SATK10

Electronic wall-hanging HIU for domestic hot water production only.

Go to
SATK10203HE.png
SATK10203HE_dim~-~page-1.png
SATK10203HE_idr~-~page-1.png
SATK10203HE.png
SATK10203HE_dim~-~page-1.png
SATK10203HE_idr~-~page-1.png
Download high resolution

Product Description

Electronic wall-hanging HIU for domestic hot water production only.

Technical data

Maximum working pressure: 10 bar
Primary inlet working temperature range: 2–85 °C
Adjustment temperature range (DHW): 42–60 °C
Electric supply: 230 V AC
Running power consumption: 80 W
Depth: 188 mm
Height: 350 mm
Width: 476 mm
△p max.: 0,9 bar

Certifications

CE
PZH

Drawings and specifications

Part number Note Nominal heat exchanger capacity Maximum DHW instantaneous production
2D drawings
Download
Download
3D models
Download
Download
Tender text
Electronic wall-hanging HIU for domestic hot water production only. Maximum working pressure: 10 bar. Primary inlet working temperature range: 2–85 °C. Adjustment temperature range (DHW): 42–60 °C. Electric supply: 230 V AC. Running power consumption: 80 W. Nominal heat exchanger capacity: 40 kW. Depth: 188 mm. Height: 350 mm. Width: 476 mm. Maximum DHW instantaneous production: 18 l/min. △p max.: 0,9 bar.
2D drawings
Download
Download
3D models
Download
Download
Tender text
Electronic wall-hanging HIU for domestic hot water production only. Maximum working pressure: 10 bar. Primary inlet working temperature range: 2–85 °C. Adjustment temperature range (DHW): 42–60 °C. Electric supply: 230 V AC. Running power consumption: 80 W. Nominal heat exchanger capacity: 65 kW. Depth: 188 mm. Height: 350 mm. Width: 476 mm. Maximum DHW instantaneous production: 25 l/min. △p max.: 0,9 bar.
2D drawings
Download
Download
3D models
Download
Download
Tender text
Electronic wall-hanging HIU for domestic hot water production only. Maximum working pressure: 10 bar. Primary inlet working temperature range: 2–85 °C. Adjustment temperature range (DHW): 42–60 °C. Electric supply: 230 V AC. Running power consumption: 80 W. Nominal heat exchanger capacity: 75 kW. Depth: 188 mm. Height: 350 mm. Width: 476 mm. Maximum DHW instantaneous production: 27 l/min. △p max.: 0,9 bar.
2D drawings
Download
Download
3D models
Download
Download
Tender text
Electronic wall-hanging HIU for domestic hot water production only. Maximum working pressure: 10 bar. Primary inlet working temperature range: 2–85 °C. Adjustment temperature range (DHW): 42–60 °C. Electric supply: 230 V AC. Running power consumption: 80 W. Nominal heat exchanger capacity: 40 kW. Depth: 188 mm. Height: 350 mm. Width: 476 mm. Maximum DHW instantaneous production: 18 l/min. △p max.: 0,9 bar.
2D drawings
Download
Download
3D models
Download
Download
Tender text
Electronic wall-hanging HIU for domestic hot water production only. Maximum working pressure: 10 bar. Primary inlet working temperature range: 2–85 °C. Adjustment temperature range (DHW): 42–60 °C. Electric supply: 230 V AC. Running power consumption: 80 W. Nominal heat exchanger capacity: 65 kW. Depth: 188 mm. Height: 350 mm. Width: 476 mm. Maximum DHW instantaneous production: 25 l/min. △p max.: 0,9 bar.
2D drawings
Download
Download
3D models
Download
Download
Tender text
Electronic wall-hanging HIU for domestic hot water production only. Maximum working pressure: 10 bar. Primary inlet working temperature range: 2–85 °C. Adjustment temperature range (DHW): 42–60 °C. Electric supply: 230 V AC. Running power consumption: 80 W. Nominal heat exchanger capacity: 75 kW. Depth: 188 mm. Height: 350 mm. Width: 476 mm. Maximum DHW instantaneous production: 27 l/min. △p max.: 0,9 bar.

Applications

DWS

Caleffi Domestic Water Sizer allows fast and correct sizing of the main components of domestic water systems.

Pipe Sizer Caleffi
Pipe Sizer Caleffi

This application allows for sizing and making calculations for pipes and conduits carrying water or air, respectively for hydraulic or aeraulic plants.

Scroll