Changeover and distribution unit pre-assembled in box for radiant panel/ fan-coil systems.
Product Description
Changeover and distribution unit pre-assembled in box for radiant panel/ fan-coil systems.
Equipped with:
- distribution manifold for radiant panel systems with flow meters and shut- off valves, insulated,
- distribution manifold for fan-coil systems with lockshield valves for preset flow rate and shut-off valves, insulated,
- three-way diverter valve with three-point control, complete with insulation and anti-condensation spacer,
- check valve kit,
- box with adjustable depth 110 - 140 mm.
Technical data
Maximum working pressure:
6 bar
Medium temperature range:
5–60 °C
Electric supply:
230 V AC
Outlet centre distance:
50 mm
Download
Drawings and specifications
Part number | Main connection | Outlet connection to radiant panels | Outlet connection to ventil |
---|---|---|---|
6640F1 | R 1" (EN 10226-1) M |
G 3/4" A (ISO 228-1) M 6 outlets |
G 3/4" A (ISO 228-1) M 4 outlets |
2D drawings
3D models
Tender text
Changeover and distribution unit pre-assembled in box for radiant panel/ fan-coil systems.
With insulation.
Equipped with:
- distribution manifold for radiant panel systems with flow meters and shut- off valves, insulated,
- distribution manifold for fan-coil systems with lockshield valves for preset flow rate and shut-off valves, insulated,
- three-way diverter valve with three-point control, complete with insulation and anti-condensation spacer,
- check valve kit,
- box with adjustable depth 110 - 140 mm.
Main connection: R 1" (EN 10226-1) M. Outlet connection to radiant panels: G 3/4" A (ISO 228-1) M, 6 outlets, Connection for Caleffi fittings. Outlet connection to ventil: G 3/4" A (ISO 228-1) M, 4 outlets, Connection for Caleffi fittings. Maximum working pressure: 6 bar. Medium temperature range: 5–60 °C. Electric supply: 230 V AC. Outlet centre distance: 50 mm.
SCIP code
CODICE IN FASE DI ANALISI
|
|||
6640G1 | R 1" (EN 10226-1) M |
G 3/4" A (ISO 228-1) M 7 outlets |
G 3/4" A (ISO 228-1) M 4 outlets |
3D models
Tender text
Changeover and distribution unit pre-assembled in box for radiant panel/ fan-coil systems.
With insulation.
Equipped with:
- distribution manifold for radiant panel systems with flow meters and shut- off valves, insulated,
- distribution manifold for fan-coil systems with lockshield valves for preset flow rate and shut-off valves, insulated,
- three-way diverter valve with three-point control, complete with insulation and anti-condensation spacer,
- check valve kit,
- box with adjustable depth 110 - 140 mm.
Main connection: R 1" (EN 10226-1) M. Outlet connection to radiant panels: G 3/4" A (ISO 228-1) M, 7 outlets, Connection for Caleffi fittings. Outlet connection to ventil: G 3/4" A (ISO 228-1) M, 4 outlets, Connection for Caleffi fittings. Maximum working pressure: 6 bar. Medium temperature range: 5–60 °C. Electric supply: 230 V AC. Outlet centre distance: 50 mm.
SCIP code
CODICE IN FASE DI ANALISI
|
|||
6640H1 | R 1" (EN 10226-1) M |
G 3/4" A (ISO 228-1) M 8 outlets |
G 3/4" A (ISO 228-1) M 4 outlets |
3D models
Tender text
Changeover and distribution unit pre-assembled in box for radiant panel/ fan-coil systems.
With insulation.
Equipped with:
- distribution manifold for radiant panel systems with flow meters and shut- off valves, insulated,
- distribution manifold for fan-coil systems with lockshield valves for preset flow rate and shut-off valves, insulated,
- three-way diverter valve with three-point control, complete with insulation and anti-condensation spacer,
- check valve kit,
- box with adjustable depth 110 - 140 mm.
Main connection: R 1" (EN 10226-1) M. Outlet connection to radiant panels: G 3/4" A (ISO 228-1) M, 8 outlets, Connection for Caleffi fittings. Outlet connection to ventil: G 3/4" A (ISO 228-1) M, 4 outlets, Connection for Caleffi fittings. Maximum working pressure: 6 bar. Medium temperature range: 5–60 °C. Electric supply: 230 V AC. Outlet centre distance: 50 mm.
SCIP code
CODICE IN FASE DI ANALISI
|
|||
6640I1 | R 1" (EN 10226-1) M |
G 3/4" A (ISO 228-1) M 9 outlets |
G 3/4" A (ISO 228-1) M 4 outlets |
3D models
Tender text
Changeover and distribution unit pre-assembled in box for radiant panel/ fan-coil systems.
With insulation.
Equipped with:
- distribution manifold for radiant panel systems with flow meters and shut- off valves, insulated,
- distribution manifold for fan-coil systems with lockshield valves for preset flow rate and shut-off valves, insulated,
- three-way diverter valve with three-point control, complete with insulation and anti-condensation spacer,
- check valve kit,
- box with adjustable depth 110 - 140 mm.
Main connection: R 1" (EN 10226-1) M. Outlet connection to radiant panels: G 3/4" A (ISO 228-1) M, 9 outlets, Connection for Caleffi fittings. Outlet connection to ventil: G 3/4" A (ISO 228-1) M, 4 outlets, Connection for Caleffi fittings. Maximum working pressure: 6 bar. Medium temperature range: 5–60 °C. Electric supply: 230 V AC. Outlet centre distance: 50 mm.
SCIP code
CODICE IN FASE DI ANALISI
|
|||
6640L1 | R 1" (EN 10226-1) M |
G 3/4" A (ISO 228-1) M 10 outlets |
G 3/4" A (ISO 228-1) M 4 outlets |
3D models
Tender text
Changeover and distribution unit pre-assembled in box for radiant panel/ fan-coil systems.
With insulation.
Equipped with:
- distribution manifold for radiant panel systems with flow meters and shut- off valves, insulated,
- distribution manifold for fan-coil systems with lockshield valves for preset flow rate and shut-off valves, insulated,
- three-way diverter valve with three-point control, complete with insulation and anti-condensation spacer,
- check valve kit,
- box with adjustable depth 110 - 140 mm.
Main connection: R 1" (EN 10226-1) M. Outlet connection to radiant panels: G 3/4" A (ISO 228-1) M, 10 outlets, Connection for Caleffi fittings. Outlet connection to ventil: G 3/4" A (ISO 228-1) M, 4 outlets, Connection for Caleffi fittings. Maximum working pressure: 6 bar. Medium temperature range: 5–60 °C. Electric supply: 230 V AC. Outlet centre distance: 50 mm.
SCIP code
CODICE IN FASE DI ANALISI
|
|||
6640M1 | R 1" (EN 10226-1) M |
G 3/4" A (ISO 228-1) M 11 outlets |
G 3/4" A (ISO 228-1) M 4 outlets |
2D drawings
3D models
Tender text
Changeover and distribution unit pre-assembled in box for radiant panel/ fan-coil systems.
With insulation.
Equipped with:
- distribution manifold for radiant panel systems with flow meters and shut- off valves, insulated,
- distribution manifold for fan-coil systems with lockshield valves for preset flow rate and shut-off valves, insulated,
- three-way diverter valve with three-point control, complete with insulation and anti-condensation spacer,
- check valve kit,
- box with adjustable depth 110 - 140 mm.
Main connection: R 1" (EN 10226-1) M. Outlet connection to radiant panels: G 3/4" A (ISO 228-1) M, 11 outlets, Connection for Caleffi fittings. Outlet connection to ventil: G 3/4" A (ISO 228-1) M, 4 outlets, Connection for Caleffi fittings. Maximum working pressure: 6 bar. Medium temperature range: 5–60 °C. Electric supply: 230 V AC. Outlet centre distance: 50 mm.
SCIP code
CODICE IN FASE DI ANALISI
|