Series 6443

Motorised three-way diverter valve.

Go to
644342.png
644342_dim~-~page-1.png
644342.png
644342_dim~-~page-1.png
Download high resolution

Product Description

Motorised three-way diverter valve.
Complete with motor with 3-contact control.
With auxiliary microswitch.
PATENT

Technical data

Maximum working pressure: 10 bar
Medium temperature range: -5–110 °C
Ambient temperature range: 0–55 °C
Power consumption: 4 VA
Protection class: IP 40 (horizontal position), IP 44 (vertical position)
Supply cable length: 1 m
Auxiliary microswitch contact rating (230 V): 0,8 A
△p max.: 10 bar
Operating time: 40 s
Operating time - Note: 90° rotation

Certifications

ACS
CE
ENEC13
PZH

Drawings and specifications

Part number Connection Electric supply Kv
3D models
Tender text
Motorised three-way diverter valve. With auxiliary microswitch. Complete with motor with 3-contact control. Connection: G 1/2" A (ISO 228-1) M. Maximum working pressure: 10 bar. Medium temperature range: -5–110 °C. Ambient temperature range: 0–55 °C. Electric supply: 230 V (AC). Power consumption: 4 VA. Protection class: IP 40 (horizontal position), IP 44 (vertical position). Supply cable length: 1 m. Auxiliary microswitch contact rating (230 V): 0,8 A. △p max.: 10 bar. Kv: 3,9 m³/h. Operating time: 40 s (90° rotation).
SCIP code
61ef2538-74b3-4103-a983-d4ec4cda04a1
2D drawings
Download
Download
3D models
Download
Download
Tender text
Motorised three-way diverter valve. With auxiliary microswitch. Complete with motor with 3-contact control. Connection: G 3/4" A (ISO 228-1) M. Maximum working pressure: 10 bar. Medium temperature range: -5–110 °C. Ambient temperature range: 0–55 °C. Electric supply: 230 V (AC). Power consumption: 4 VA. Protection class: IP 40 (horizontal position), IP 44 (vertical position). Supply cable length: 1 m. Auxiliary microswitch contact rating (230 V): 0,8 A. △p max.: 10 bar. Kv: 3,9 m³/h. Operating time: 40 s (90° rotation).
SCIP code
7e7ebc3a-c81c-4a06-80b1-f58b13af520f
3D models
Tender text
Motorised three-way diverter valve. With auxiliary microswitch. Complete with motor with 3-contact control. Connection: R 3/4" (EN 10226-1) M. Maximum working pressure: 10 bar. Medium temperature range: -5–110 °C. Ambient temperature range: 0–55 °C. Electric supply: 230 V (AC). Power consumption: 4 VA. Protection class: IP 44 (vertical position), IP 40 (horizontal position). Supply cable length: 1 m. Auxiliary microswitch contact rating (230 V): 0,8 A. △p max.: 10 bar. Kv: 8,6 m³/h. Operating time: 40 s (90° rotation).
SCIP code
7a49a48c-3a59-44f5-b3de-f866e2e2d5e6
3D models
Tender text
Motorised three-way diverter valve. With auxiliary microswitch. Complete with motor with 3-contact control. Connection: R 1" (EN 10226-1) M. Maximum working pressure: 10 bar. Medium temperature range: -5–110 °C. Ambient temperature range: 0–55 °C. Electric supply: 230 V (AC). Power consumption: 4 VA. Protection class: IP 40 (horizontal position), IP 44 (vertical position). Supply cable length: 1 m. Auxiliary microswitch contact rating (230 V): 0,8 A. △p max.: 10 bar. Kv: 9,0 m³/h. Operating time: 40 s (90° rotation).
SCIP code
f7532cc4-d0a1-4243-989e-4b3d16e7025e
2D drawings
Download
Download
3D models
Download
Download
Tender text
Motorised three-way diverter valve. With auxiliary microswitch. Complete with motor with 3-contact control. Connection: G 1/2" A (ISO 228-1) M. Maximum working pressure: 10 bar. Medium temperature range: -5–110 °C. Ambient temperature range: 0–55 °C. Electric supply: 24 V (AC). Power consumption: 4 VA. Protection class: IP 44 (vertical position), IP 40 (horizontal position). Supply cable length: 1 m. Auxiliary microswitch contact rating (230 V): 0,8 A. △p max.: 10 bar. Kv: 3,9 m³/h. Operating time: 40 s (90° rotation).
SCIP code
8455d1fc-91e1-4711-9925-e770105a5ec7
3D models
Tender text
Motorised three-way diverter valve. With auxiliary microswitch. Complete with motor with 3-contact control. Connection: G 3/4" A (ISO 228-1) M. Maximum working pressure: 10 bar. Medium temperature range: -5–110 °C. Ambient temperature range: 0–55 °C. Electric supply: 24 V (AC). Power consumption: 4 VA. Protection class: IP 44 (vertical position), IP 40 (horizontal position). Supply cable length: 1 m. Auxiliary microswitch contact rating (230 V): 0,8 A. △p max.: 10 bar. Kv: 3,9 m³/h. Operating time: 40 s (90° rotation).
SCIP code
6c1526df-068f-45fa-bf46-0cc7f8478798
3D models
Tender text
Motorised three-way diverter valve. With auxiliary microswitch. Complete with motor with 3-contact control. Connection: R 3/4" (EN 10226-1) M. Maximum working pressure: 10 bar. Medium temperature range: -5–110 °C. Ambient temperature range: 0–55 °C. Electric supply: 24 V (AC). Power consumption: 4 VA. Protection class: IP 40 (horizontal position), IP 44 (vertical position). Supply cable length: 1 m. Auxiliary microswitch contact rating (230 V): 0,8 A. △p max.: 10 bar. Kv: 8,6 m³/h. Operating time: 40 s (90° rotation).
SCIP code
9719f0bb-72f4-4a62-be57-50ed26d990ac
3D models
Tender text
Motorised three-way diverter valve. With auxiliary microswitch. Complete with motor with 3-contact control. Connection: R 1" (EN 10226-1) M. Maximum working pressure: 10 bar. Medium temperature range: -5–110 °C. Ambient temperature range: 0–55 °C. Electric supply: 24 V (AC). Power consumption: 4 VA. Protection class: IP 40 (horizontal position), IP 44 (vertical position). Supply cable length: 1 m. Auxiliary microswitch contact rating (230 V): 0,8 A. △p max.: 10 bar. Kv: 9,0 m³/h. Operating time: 40 s (90° rotation).
SCIP code
391923d3-60f5-4175-bd91-712b8b53b2ab

Applications

Pipe Sizer Caleffi
Pipe Sizer Caleffi

This application allows for sizing and making calculations for pipes and conduits carrying water or air, respectively for hydraulic or aeraulic plants.