Technical data
Maximum operating pressure:
300 psi
Fluid temperature range:
32–240 °F
Electric supply:
24 V (AC)
Power consumption at full capacity:
7 VA
Auxiliary microswitch contact rating (24 V):
0.4 A
Maximum glycol %:
50 %
Medium:
water, glycol solutions, vapor (max. 15 psi)
Download
Drawings and specifications
Part number | Connection | Maximum △p | Cv |
---|---|---|---|
Z44P | 1/2" press union |
30 psi | 3.5 gpm |
3D models
Tender text
2-way motorized zone valve (press)
With auxiliary microswitch.
UL873, cULus Listed & CE. UL 1995 sec. 18 air plenums and ducts.U.S. Patent 7,048,251. Auxiliary micro-switch. Overall length: 5-5/8". Spring return. Connection: 1/2", press union. Maximum working pressure: 300 psi. Medium temperature range: 32–240 °F. Electric supply: 24 V (AC). Power consumption: 7 VA. Auxiliary microswitch contact rating (24 V): 0.4 A. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions, vapor (max. 15 psi). △p max.: 30 psi. Cv: 3.5 gpm.
|
|||
Z54P | 1/2" press union |
30 psi | 3.5 gpm |
3D models
Tender text
2-way motorized zone valve (press)
With auxiliary microswitch.
UL873, cULus Listed & CE. UL 1995 sec. 18 air plenums and ducts.U.S. Patent 7,048,251. Auxiliary micro-switch. Overall length: 5-5/8". Spring return. Connection: 1/2", press union. Maximum working pressure: 300 psi. Medium temperature range: 32–240 °F. Electric supply: 24 V (AC). Power consumption: 7 VA. Auxiliary microswitch contact rating (24 V): 0.4 A. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions, vapor (max. 15 psi). △p max.: 30 psi. Cv: 3.5 gpm.
|
|||
Z45P | 3/4" press union |
20 psi | 7.5 gpm |
3D models
Tender text
2-way motorized zone valve (press)
With auxiliary microswitch.
UL873, cULus Listed & CE. UL 1995 sec. 18 air plenums and ducts.U.S. Patent 7,048,251. Auxiliary micro-switch. Overall length: 5-5/8". Spring return. Connection: 3/4", press union. Maximum working pressure: 300 psi. Medium temperature range: 32–240 °F. Electric supply: 24 V (AC). Power consumption: 7 VA. Auxiliary microswitch contact rating (24 V): 0.4 A. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions, vapor (max. 15 psi). △p max.: 20 psi. Cv: 7.5 gpm.
|
|||
Z55P | 3/4" press union |
20 psi | 7.5 gpm |
3D models
Tender text
2-way motorized zone valve (press)
With auxiliary microswitch.
UL873, cULus Listed & CE. UL 1995 sec. 18 air plenums and ducts.U.S. Patent 7,048,251. Auxiliary micro-switch. Overall length: 5-5/8". Spring return. Connection: 3/4", press union. Maximum working pressure: 300 psi. Medium temperature range: 32–240 °F. Electric supply: 24 V (AC). Power consumption: 7 VA. Auxiliary microswitch contact rating (24 V): 0.4 A. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions, vapor (max. 15 psi). △p max.: 20 psi. Cv: 7.5 gpm.
|
|||
Z45PL | 3/4" press union |
20 psi | 7.5 gpm |
3D models
Tender text
2-way motorized zone valve (press)
With auxiliary microswitch.
UL873, cULus Listed & CE. UL 1995 sec. 18 air plenums and ducts.U.S. Patent 7,048,251. Auxiliary micro-switch. Overall length: 5-5/8". Spring return. Connection: 3/4", press union. Maximum working pressure: 300 psi. Medium temperature range: 32–240 °F. Electric supply: 24 V (AC). Power consumption: 7 VA. Auxiliary microswitch contact rating (24 V): 0.4 A. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions, vapor (max. 15 psi). △p max.: 20 psi. Cv: 7.5 gpm.
|
|||
Z55PL | 3/4" press union |
20 psi | 7.5 gpm |
3D models
Tender text
2-way motorized zone valve (press)
With auxiliary microswitch.
UL873, cULus Listed & CE. UL 1995 sec. 18 air plenums and ducts.U.S. Patent 7,048,251. Auxiliary micro-switch. Overall length: 5-5/8". Spring return. Connection: 3/4", press union. Maximum working pressure: 300 psi. Medium temperature range: 32–240 °F. Electric supply: 24 V (AC). Power consumption: 7 VA. Auxiliary microswitch contact rating (24 V): 0.4 A. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions, vapor (max. 15 psi). △p max.: 20 psi. Cv: 7.5 gpm.
|
|||
Z46P | 1" press union |
20 psi | 7.5 gpm |
3D models
Tender text
2-way motorized zone valve (press)
With auxiliary microswitch.
UL873, cULus Listed & CE. UL 1995 sec. 18 air plenums and ducts.U.S. Patent 7,048,251. Auxiliary micro-switch. Overall length: 5-5/8". Spring return. Connection: 1", press union. Maximum working pressure: 300 psi. Medium temperature range: 32–240 °F. Electric supply: 24 V (AC). Power consumption: 7 VA. Auxiliary microswitch contact rating (24 V): 0.4 A. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions, vapor (max. 15 psi). △p max.: 20 psi. Cv: 7.5 gpm.
|
|||
Z56P | 1" press union |
20 psi | 7.5 gpm |
3D models
Tender text
2-way motorized zone valve (press)
With auxiliary microswitch.
UL873, cULus Listed & CE. UL 1995 sec. 18 air plenums and ducts.U.S. Patent 7,048,251. Auxiliary micro-switch. Overall length: 5-5/8". Spring return. Connection: 1", press union. Maximum working pressure: 300 psi. Medium temperature range: 32–240 °F. Electric supply: 24 V (AC). Power consumption: 7 VA. Auxiliary microswitch contact rating (24 V): 0.4 A. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions, vapor (max. 15 psi). △p max.: 20 psi. Cv: 7.5 gpm.
|
|||
Z55S | 3/4" sweat union |
20 psi | 7.5 gpm |
3D models
Tender text
2-way motorized zone valve (press)
With auxiliary microswitch.
UL873, cULus Listed & CE. UL 1995 sec. 18 air plenums and ducts.U.S. Patent 7,048,251. Auxiliary micro-switch. Overall length: 5-5/8". Spring return. Connection: 3/4", sweat union. Maximum working pressure: 300 psi. Medium temperature range: 32–240 °F. Electric supply: 24 V (AC). Power consumption: 7 VA. Auxiliary microswitch contact rating (24 V): 0.4 A. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions, vapor (max. 15 psi). △p max.: 20 psi. Cv: 7.5 gpm.
|