Series 7507

CONTECA® EASY ULTRA, Direct heat meter for heating and cooling systems (*).

Go to
750704.png
750704_dim~-~page-1.png
750704_app~-~page-1.png
750704.png
750704_dim~-~page-1.png
750704_app~-~page-1.png
Download high resolution

Product Description

Direct heat meter for heating and cooling systems (*).
Complete with:
- electronic integrator with LCD display;
- pair of temperature probes ;
- pair of weld sleeve and probe pockets;
- ultrasonic volume meter with pulse output;
- 2 pulse inlets for DCW and DHW reading.
Can be integrated with additional configuration options, to be ordered concurrently (*).

Technical data

Communication protocol: M-Bus on RS485
Protection class: IP 54
Running power consumption: 1 W
Electric supply: 24 V AC
Probe/cable length: 1,9 m
Accuracy class: 2
Nominal pressure: PN 16
Medium temperature range: 2–90 °C

Note

(*) Available configuration options:
- Cooling metering option (cod. 755810)
- MODBUS-RTU transmission option (cod. 750811)
- Flow rate scanning software option for DHW recirculation (cod. 755826)
- Couple of 8 m temperature probes (cod. 750931)

Certifications

CE
MI004

Drawings and specifications

Part number Connection Note Permanent flow rate (Qp)
Minimum flow rate (Qi)
6 l/h
2D drawings
Download
Download
3D models
Download
Download
Tender text
CALEFFI, 750704, CONTECA® EASY ULTRA. Direct ultrasonic heat meter for zone systems and central heating systems. The metering module is supplied complete with: - pair of immersion temperature probes (L= 1,9 m); - pair of Y pockets; - Ultrasound measuring device; - electronic integrator with LCD display. Local reading via LCD display/centralised reading via BUS transmission. Strainer mesh located in flow pocket. Connection: G 1/2" A (ISO 228-1) M. Medium temperature range: 2–90 °C. Electric supply: 24 V AC. Running power consumption: 1 W. Protection class: IP 54. Probe/cable length: 1,9 m. Nominal pressure: PN 16. Accuracy class: 2. Permanent flow rate (Qp): 1,5 m³/h. Minimum flow rate (Qi): 6 l/h. Communication protocol: M-Bus on RS485.
SCIP code
30acf4e4-0780-4e58-8827-8af4ec780865
Minimum flow rate (Qi)
10 l/h
2D drawings
Download
Download
3D models
Download
Download
Tender text
CALEFFI, 750705, CONTECA® EASY ULTRA. Direct ultrasonic heat meter for zone systems and central heating systems. The metering module is supplied complete with: - pair of immersion temperature probes (L= 1,9 m); - pair of Y pockets; - Ultrasound measuring device; - electronic integrator with LCD display. Local reading via LCD display/centralised reading via BUS transmission. Strainer mesh located in flow pocket. Connection: G 3/4" A (ISO 228-1) M. Medium temperature range: 2–90 °C. Electric supply: 24 V AC. Running power consumption: 1 W. Protection class: IP 54. Probe/cable length: 1,9 m. Nominal pressure: PN 16. Accuracy class: 2. Permanent flow rate (Qp): 2,5 m³/h. Minimum flow rate (Qi): 10 l/h. Communication protocol: M-Bus on RS485.
SCIP code
9e1bc076-97f0-4a31-98d4-b124b1b252c8
Minimum flow rate (Qi)
35 l/h
2D drawings
Download
Download
3D models
Download
Download
Tender text
CALEFFI, 750706, CONTECA® EASY ULTRA. Direct ultrasonic heat meter for zone systems and central heating systems. The metering module is supplied complete with: - pair of immersion temperature probes (L= 1,9 m); - pair of Y pockets; - Ultrasound measuring device; - electronic integrator with LCD display. Local reading via LCD display/centralised reading via BUS transmission. Strainer mesh located in flow pocket. Connection: G 1" A (ISO 228-1) M. Medium temperature range: 2–90 °C. Electric supply: 24 V AC. Running power consumption: 1 W. Protection class: IP 54. Probe/cable length: 1,9 m. Nominal pressure: PN 16. Accuracy class: 2. Permanent flow rate (Qp): 3,5 m³/h. Minimum flow rate (Qi): 35 l/h. Communication protocol: M-Bus on RS485.
SCIP code
1e960c85-a71e-4e62-af6e-3daf525350de
Minimum flow rate (Qi)
24 l/h
2D drawings
Download
Download
3D models
Download
Download
Tender text
CALEFFI, 750707, CONTECA® EASY ULTRA. Direct ultrasonic heat meter for zone systems and central heating systems. The metering module is supplied complete with: - pair of immersion temperature probes (L= 1,9 m); - pair of Y pockets; - Ultrasound measuring device; - electronic integrator with LCD display. Local reading via LCD display/centralised reading via BUS transmission. Strainer mesh located in flow pocket. Connection: G 1 1/4" A (ISO 228-1) M. Medium temperature range: 2–90 °C. Electric supply: 24 V AC. Running power consumption: 1 W. Protection class: IP 54. Probe/cable length: 1,9 m. Nominal pressure: PN 16. Accuracy class: 2. Permanent flow rate (Qp): 6 m³/h. Minimum flow rate (Qi): 24 l/h. Communication protocol: M-Bus on RS485.
SCIP code
4807cc06-544d-420c-9c21-265b8be20208
Minimum flow rate (Qi)
40/100 l/h
2D drawings
Download
Download
3D models
Download
Download
Tender text
CALEFFI, 750708, CONTECA® EASY ULTRA. Direct ultrasonic heat meter for zone systems and central heating systems. The metering module is supplied complete with: - pair of immersion temperature probes (L= 1,9 m); - pair of Y pockets; - Ultrasound measuring device; - electronic integrator with LCD display. Local reading via LCD display/centralised reading via BUS transmission. Strainer mesh located in flow pocket. Connection: G 1 1/2" A (ISO 228-1) M. Medium temperature range: 2–90 °C. Electric supply: 24 V AC. Running power consumption: 1 W. Protection class: IP 54. Probe/cable length: 1,9 m. Nominal pressure: PN 16. Accuracy class: 2. Permanent flow rate (Qp): 10 m³/h. Minimum flow rate (Qi): 40/100 l/h. Communication protocol: M-Bus on RS485.
SCIP code
954d2166-4294-45b4-9504-fe18375a5c98