Direct heat meter for heating and cooling systems (*).
Complete with:
- electronic integrator with LCD display;
- pair of temperature probes ;
- pair of Y fitting probe pockets;
- ultrasonic volume meter with pulse output;
- 2 pulse inlets for DCW and DHW reading.
Can be integrated with additional configuration options, to be ordered concurrently (*).

Technical data

Communication protocol: M-Bus on RS485
Protection class: IP 54
Running power consumption: 1 W
Electric supply: 24 V AC
Probe/cable length: 1,9 m
Accuracy class: 2
Nominal pressure: PN 16
Medium temperature range: 2–90 °C

Note

(*) Available configuration options:
- Cooling metering option (cod. 755810)
- MODBUS-RTU transmission option (cod. 750811)
- Flow rate scanning software option for DHW recirculation (cod. 755826)
- Couple of 8 m temperature probes (cod. 750931)

Services and Connectivity

Certifications

CE
MI004

Drawings and specifications

Part number Connection Permanent flow rate (Qp) Minimum flow rate (Qi)
2D drawings
Download
Download
3D models
Download
Download
Tender text
CALEFFI, 750704, CONTECA® EASY ULTRA. Direct heat meter for heating and cooling systems (*). Complete with: - electronic integrator with LCD display; - pair of temperature probes ; - pair of Y fitting probe pockets; - ultrasonic volume meter with pulse output; - 2 pulse inlets for DCW and DHW reading. Can be integrated with additional configuration options, to be ordered concurrently (*). Connection: G 1/2" A (ISO 228-1) M. Medium temperature range: 2–90 °C. Electric supply: 24 V AC. Running power consumption: 1 W. Protection class: IP 54. Probe/cable length: 1,9 m. Nominal pressure: PN 16. Accuracy class: 2. Permanent flow rate (Qp): 1,5 m³/h. Minimum flow rate (Qi): 6 l/h. Communication protocol: M-Bus on RS485.
SCIP code
30acf4e4-0780-4e58-8827-8af4ec780865
2D drawings
Download
Download
3D models
Download
Download
Tender text
CALEFFI, 750705, CONTECA® EASY ULTRA. Direct heat meter for heating and cooling systems (*). Complete with: - electronic integrator with LCD display; - pair of temperature probes ; - pair of Y fitting probe pockets; - ultrasonic volume meter with pulse output; - 2 pulse inlets for DCW and DHW reading. Can be integrated with additional configuration options, to be ordered concurrently (*). Connection: G 3/4" A (ISO 228-1) M. Medium temperature range: 2–90 °C. Electric supply: 24 V AC. Running power consumption: 1 W. Protection class: IP 54. Probe/cable length: 1,9 m. Nominal pressure: PN 16. Accuracy class: 2. Permanent flow rate (Qp): 2,5 m³/h. Minimum flow rate (Qi): 10 l/h. Communication protocol: M-Bus on RS485.
SCIP code
9e1bc076-97f0-4a31-98d4-b124b1b252c8
2D drawings
Download
Download
3D models
Download
Download
Tender text
CALEFFI, 750706, CONTECA® EASY ULTRA. Direct heat meter for heating and cooling systems (*). Complete with: - electronic integrator with LCD display; - pair of temperature probes ; - pair of Y fitting probe pockets; - ultrasonic volume meter with pulse output; - 2 pulse inlets for DCW and DHW reading. Can be integrated with additional configuration options, to be ordered concurrently (*). Connection: G 1" A (ISO 228-1) M. Medium temperature range: 2–90 °C. Electric supply: 24 V AC. Running power consumption: 1 W. Protection class: IP 54. Probe/cable length: 1,9 m. Nominal pressure: PN 16. Accuracy class: 2. Permanent flow rate (Qp): 3,5 m³/h. Minimum flow rate (Qi): 35 l/h. Communication protocol: M-Bus on RS485.
SCIP code
1e960c85-a71e-4e62-af6e-3daf525350de
2D drawings
Download
Download
3D models
Download
Download
Tender text
CALEFFI, 750707, CONTECA® EASY ULTRA. Direct heat meter for heating and cooling systems (*). Complete with: - electronic integrator with LCD display; - pair of temperature probes ; - pair of Y fitting probe pockets; - ultrasonic volume meter with pulse output; - 2 pulse inlets for DCW and DHW reading. Can be integrated with additional configuration options, to be ordered concurrently (*). Connection: G 1 1/4" A (ISO 228-1) M. Medium temperature range: 2–90 °C. Electric supply: 24 V AC. Running power consumption: 1 W. Protection class: IP 54. Probe/cable length: 1,9 m. Nominal pressure: PN 16. Accuracy class: 2. Permanent flow rate (Qp): 6 m³/h. Minimum flow rate (Qi): 24 l/h. Communication protocol: M-Bus on RS485.
SCIP code
4807cc06-544d-420c-9c21-265b8be20208
2D drawings
Download
Download
3D models
Download
Download
Tender text
CALEFFI, 750708, CONTECA® EASY ULTRA. Direct heat meter for heating and cooling systems (*). Complete with: - electronic integrator with LCD display; - pair of temperature probes ; - pair of Y fitting probe pockets; - ultrasonic volume meter with pulse output; - 2 pulse inlets for DCW and DHW reading. Can be integrated with additional configuration options, to be ordered concurrently (*). Connection: G 1 1/2" A (ISO 228-1) M. Medium temperature range: 2–90 °C. Electric supply: 24 V AC. Running power consumption: 1 W. Protection class: IP 54. Probe/cable length: 1,9 m. Nominal pressure: PN 16. Accuracy class: 2. Permanent flow rate (Qp): 10 m³/h. Minimum flow rate (Qi): 40/100 l/h. Communication protocol: M-Bus on RS485.
SCIP code
954d2166-4294-45b4-9504-fe18375a5c98