Flow manifold. 11/4'' connections.
Product Description
Flow manifold. 11/4'' connections.
Complete with built-in flow meters and flow rate balancing valves.
Technical data
Maximum working pressure:
10 bar
Medium temperature range:
0–80 °C
Outlet centre distance:
50 mm
Download
Drawings and specifications
Part number | Main connection | Connection | Outlet connection |
---|---|---|---|
667735S1 | G 1 1/4" (ISO 228-1) F inlet |
G 1 1/4" A (ISO 228-1) M end outlet |
Ga 3/4" (ISO 228-1) M 3 outlets |
3D models
Tender text
Flow manifold. 11/4'' connections.
Complete with built-in flow meters and flow rate balancing valves.
main connection: G 1 1/4" (ISO 228-1) F, inlet, Connection for Caleffi fittings. Connection: G 1 1/4" A (ISO 228-1) M, end outlet. outlet connection: Ga 3/4" (ISO 228-1) M, 3 outlets. Maximum working pressure: 10 bar. Medium temperature range: 0–80 °C. Outlet centre distance: 50 mm.
SCIP code
a78d0950-cfd0-4ba7-be75-d454f852d0f6
|
|||
667745S1 | G 1 1/4" (ISO 228-1) F inlet |
G 1 1/4" A (ISO 228-1) M end outlet |
Ga 3/4" (ISO 228-1) M 4 outlets |
3D models
Tender text
Flow manifold. 11/4'' connections.
Complete with built-in flow meters and flow rate balancing valves.
main connection: G 1 1/4" (ISO 228-1) F, inlet, Connection for Caleffi fittings. Connection: G 1 1/4" A (ISO 228-1) M, end outlet. outlet connection: Ga 3/4" (ISO 228-1) M, 4 outlets. Maximum working pressure: 10 bar. Medium temperature range: 0–80 °C. Outlet centre distance: 50 mm.
SCIP code
c3e413db-0a84-4d65-a2ec-4f0df2c52837
|
|||
667755S1 | G 1 1/4" (ISO 228-1) F inlet |
G 1 1/4" A (ISO 228-1) M end outlet |
Ga 3/4" (ISO 228-1) M 5 outlets |
3D models
Tender text
Flow manifold. 11/4'' connections.
Complete with built-in flow meters and flow rate balancing valves.
main connection: G 1 1/4" (ISO 228-1) F, inlet, Connection for Caleffi fittings. Connection: G 1 1/4" A (ISO 228-1) M, end outlet. outlet connection: Ga 3/4" (ISO 228-1) M, 5 outlets. Maximum working pressure: 10 bar. Medium temperature range: 0–80 °C. Outlet centre distance: 50 mm.
SCIP code
d013c852-1e6b-42f2-9a5c-1aa47820c2a1
|
|||
667765S1 | G 1 1/4" (ISO 228-1) F inlet |
G 1 1/4" A (ISO 228-1) M end outlet |
Ga 3/4" (ISO 228-1) M 6 outlets |
3D models
Tender text
Flow manifold. 11/4'' connections.
Complete with built-in flow meters and flow rate balancing valves.
main connection: G 1 1/4" (ISO 228-1) F, inlet, Connection for Caleffi fittings. Connection: G 1 1/4" A (ISO 228-1) M, end outlet. outlet connection: Ga 3/4" (ISO 228-1) M, 6 outlets. Maximum working pressure: 10 bar. Medium temperature range: 0–80 °C. Outlet centre distance: 50 mm.
SCIP code
4718c3da-4bd4-4065-8744-e1cc124d6d0f
|
|||
667775S1 | G 1 1/4" (ISO 228-1) F inlet |
G 1 1/4" A (ISO 228-1) M end outlet |
Ga 3/4" (ISO 228-1) M 7 outlets |
3D models
Tender text
Flow manifold. 11/4'' connections.
Complete with built-in flow meters and flow rate balancing valves.
main connection: G 1 1/4" (ISO 228-1) F, inlet, Connection for Caleffi fittings. Connection: G 1 1/4" A (ISO 228-1) M, end outlet. outlet connection: Ga 3/4" (ISO 228-1) M, 7 outlets. Maximum working pressure: 10 bar. Medium temperature range: 0–80 °C. Outlet centre distance: 50 mm.
SCIP code
cd387704-4d77-4f45-8213-afb6ff330e3c
|
|||
667785S1 | G 1 1/4" (ISO 228-1) F inlet |
G 1 1/4" A (ISO 228-1) M end outlet |
Ga 3/4" (ISO 228-1) M 8 outlets |
3D models
Tender text
Flow manifold. 11/4'' connections.
Complete with built-in flow meters and flow rate balancing valves.
main connection: G 1 1/4" (ISO 228-1) F, inlet, Connection for Caleffi fittings. Connection: G 1 1/4" A (ISO 228-1) M, end outlet. outlet connection: Ga 3/4" (ISO 228-1) M, 8 outlets. Maximum working pressure: 10 bar. Medium temperature range: 0–80 °C. Outlet centre distance: 50 mm.
SCIP code
f4ed46ad-5f99-4a46-bac7-34ff52eb0ebd
|
Faq - Frequent questions
MISSING