Series 5485

Inertial hydraulic separator for heat pump.

Go to
548515.png
Download high resolution

Product Description

Inertial hydraulic separator for heat pump.
In AISI 304 stainless steel.
With highly effective expended EPP insulation.
With insulation.

Technical data

Maximum working pressure: 4 bar
Medium temperature range: -10–95 °C
Maximum percentage of glycol: 30 %
Medium: glycol solutions, water
Material: stainless steel

Drawings and specifications

Part number Connection Maximum recommended flow rate Volume
2D drawings
Download
Download
3D models
Download
Download
Tender text
Wall-mounted buffer tank-hydraulic separator for heat pump. With insulation. Air vent top connection:  15–30 liters 1"; 50 liters 1 1/4". Drain valve bottom connection: 15–30 liters 1"; 50 liters 1 1/4". Front probe holder connection 1/4" F. In AISI 304 stainless steel. With highly effective expended EPP insulation. Connection: G 1" (ISO 228-1) F... Maximum working pressure: 4 bar. Medium temperature range: -10–95 °C. Maximum percentage of glycol: 30 %. Medium: glycol solutions, water. Maximum recommended flow rate: 3,5 m³/h. Volume: 15 l. Material: stainless steel.
SCIP code
CODICE IN FASE DI ANALISI
2D drawings
Download
Download
3D models
Download
Download
Tender text
Inertial hydraulic separator for heat pump. With insulation. In AISI 304 stainless steel. With highly effective expended EPP insulation. Connection: G 1" (ISO 228-1) F... Maximum working pressure: 4 bar. Medium temperature range: -10–95 °C. Maximum percentage of glycol: 30 %. Medium: water, glycol solutions. Maximum recommended flow rate: 3,5 m³/h. Volume: 20 l. Material: stainless steel.
SCIP code
CODICE IN FASE DI ANALISI
2D drawings
Download
Download
3D models
Download
Download
Tender text
Inertial hydraulic separator for heat pump. With insulation. In AISI 304 stainless steel. With highly effective expended EPP insulation. Connection: G 1" (ISO 228-1) F... Maximum working pressure: 4 bar. Medium temperature range: -10–95 °C. Maximum percentage of glycol: 30 %. Medium: water, glycol solutions. Maximum recommended flow rate: 3,5 m³/h. Volume: 25 l. Material: stainless steel.
SCIP code
CODICE IN FASE DI ANALISI
2D drawings
Download
Download
3D models
Download
Download
Tender text
Inertial hydraulic separator for heat pump. With insulation. In AISI 304 stainless steel. With highly effective expended EPP insulation. Connection: G 1" (ISO 228-1) F... Maximum working pressure: 4 bar. Medium temperature range: -10–95 °C. Maximum percentage of glycol: 30 %. Medium: water, glycol solutions. Maximum recommended flow rate: 3,5 m³/h. Volume: 30 l. Material: stainless steel.
SCIP code
CODICE IN FASE DI ANALISI
2D drawings
Download
Download
3D models
Download
Download
Tender text
Inertial hydraulic separator for heat pump. With insulation. In AISI 304 stainless steel. With highly effective expended EPP insulation. Connection: G 1 1/4" (ISO 228-1) F. G 1 1/4" (ISO 228-1) F. G 1/4" (ISO 228-1) F. Maximum working pressure: 4 bar. Medium temperature range: -10–95 °C. Maximum percentage of glycol: 30 %. Medium: water, glycol solutions. Maximum recommended flow rate: 5,5 m³/h. Volume: 50 l. Material: stainless steel.
SCIP code
CODICE IN FASE DI ANALISI