Series 519

Differential by-pass valve, adjustable with graduated scale.

Go to
519500.png
519500_bol~-~page-1.png
519500_dim~-~page-1.png
519500.png
519500_bol~-~page-1.png
519500_dim~-~page-1.png
Download high resolution

Product Description

Differential by-pass valve, adjustable with graduated scale.

Technical data

Maximum working pressure: 10 bar
Medium temperature range: 0–110 °C
Maximum percentage of glycol: 30 %
Medium: water, glycol solutions

Certifications

WRAS

Drawings and specifications

Part number Connection Connection Note
Setting range
1–6 m g.w.
2D drawings
Download
Download
3D models
Download
Download
Tender text
Differential by-pass valve, adjustable with graduated scale. Connection: Ø 22, inlet. Connection: Ø 22, end outlet. Maximum working pressure: 10 bar. Medium temperature range: 0–110 °C. Setting range: 1–6 m g.w.. Maximum percentage of glycol: 30 %. Medium: water, glycol solutions.
SCIP code
838add87-92eb-40e0-8364-d1f936b829cd
Setting range
1–6 m g.w.
2D drawings
Download
Download
3D models
Download
Download
Tender text
Differential by-pass valve, adjustable with graduated scale. Connection: G 3/4" (ISO 228-1) F, inlet. Connection: G 3/4" A (ISO 228-1) M, end outlet. Maximum working pressure: 10 bar. Medium temperature range: 0–110 °C. Setting range: 1–6 m g.w.. Maximum percentage of glycol: 30 %. Medium: water, glycol solutions.
SCIP code
40532ad2-c540-42dd-aa11-9d6e67e56aa7
Setting range
10–40 m g.w.
2D drawings
Download
Download
3D models
Download
Download
Tender text
Differential by-pass valve, adjustable with graduated scale. Connection: G 3/4" (ISO 228-1) F, inlet. Connection: G 3/4" A (ISO 228-1) M, end outlet. Maximum working pressure: 10 bar. Medium temperature range: 0–110 °C. Setting range: 10–40 m g.w.. Maximum percentage of glycol: 30 %. Medium: water, glycol solutions.
SCIP code
6f90cd69-104e-4c8d-87dc-685af7fd3a8b
Setting range
1–6 m g.w.
2D drawings
Download
Download
Download
3D models
Download
Download
Tender text
Differential by-pass valve, adjustable with graduated scale. Connection: G 1 1/4" (ISO 228-1) F, inlet. Connection: R 1 1/4" (EN 10226-1) M, end outlet. Maximum working pressure: 10 bar. Medium temperature range: 0–110 °C. Setting range: 1–6 m g.w.. Maximum percentage of glycol: 30 %. Medium: water, glycol solutions.
SCIP code
e2be43f5-27e7-4178-aa2f-a6caf17f59ed
Setting range
5–25 m g.w.
2D drawings
Download
Download
3D models
Download
Download
Tender text
Differential by-pass valve, adjustable with graduated scale. Connection: G 1 1/4" (ISO 228-1) F, inlet. Connection: R 1 1/4" (EN 10226-1) M, end outlet. Maximum working pressure: 10 bar. Medium temperature range: 0–110 °C. Setting range: 5–25 m g.w.. Maximum percentage of glycol: 30 %. Medium: water, glycol solutions.
SCIP code
2c5fcc23-9ccb-4dd4-902a-6fd6c9444e07

Applications

Pipe Sizer Caleffi
Pipe Sizer Caleffi

This application allows for sizing and making calculations for pipes and conduits carrying water or air, respectively for hydraulic or aeraulic plants.