Z1 actuator for motorized zone valves (opened)
Product Description
Z1 actuator for motorized zone valves (opened)
UL873, cULus Listed & CE. UL 1995 sec.18 air plenums and ducts.U.S. Patent 7,048,251.
Normally open actuators fit on Z2 valves only.
Easy pushbutton attachment 7/8" knockout for 1/2" conduit connector.
Rating of auxiliary switch contacts: 24 VAC: 0.0 A min, 0.4 A max. (24 V). 120 and Z111900 VAC: 0.25 A min, 5.0 A max. (230 V).
Conduit connector size:1/2".
With auxiliary microswitch.
Technical data
Power consumption at full capacity:
7 VA
Download
Drawings and specifications
Part number | Note | Electric supply | |
---|---|---|---|
Z131000 | Micro-switch, 18" wires | 24 V AC | |
3D models
Tender text
Z1 actuator for motorized zone valves (opened)
With auxiliary microswitch.
UL873, cULus Listed & CE. UL 1995 sec.18 air plenums and ducts.U.S. Patent 7,048,251. Normally open actuators fit on Z2 valves only. Easy pushbutton attachment 7/8" knockout for 1/2" conduit connector. Rating of auxiliary switch contacts: 24 VAC: 0.0 A min, 0.4 A max. (24 V). 120 and Z111900 VAC: 0.25 A min, 5.0 A max. (230 V). Conduit connector size:1/2". Electric supply: 24 V AC. Power consumption at full capacity: 7 VA.
|
|||
Z136000 | Micro-switch, 6" wires | 120 V (AC) | |
3D models
Tender text
Z1 actuator for motorized zone valves (opened)
With auxiliary microswitch.
UL873, cULus Listed & CE. UL 1995 sec.18 air plenums and ducts.U.S. Patent 7,048,251. Normally open actuators fit on Z2 valves only. Easy pushbutton attachment 7/8" knockout for 1/2" conduit connector. Rating of auxiliary switch contacts: 24 VAC: 0.0 A min, 0.4 A max. (24 V). 120 and Z111900 VAC: 0.25 A min, 5.0 A max. (230 V). Conduit connector size:1/2". Electric supply: 120 V (AC). Power consumption at full capacity: 7 VA.
|
|||
Z141000 | 18" wires | 24 V AC | |
3D models
Tender text
Z1 actuator for motorized zone valves (opened)
With auxiliary microswitch.
UL873, cULus Listed & CE. UL 1995 sec.18 air plenums and ducts.U.S. Patent 7,048,251. Normally open actuators fit on Z2 valves only. Easy pushbutton attachment 7/8" knockout for 1/2" conduit connector. Rating of auxiliary switch contacts: 24 VAC: 0.0 A min, 0.4 A max. (24 V). 120 and Z111900 VAC: 0.25 A min, 5.0 A max. (230 V). Conduit connector size:1/2". Electric supply: 24 V AC. Power consumption at full capacity: 7 VA.
|
|||
Z146000 | 6" wires | 120 V (AC) | |
3D models
Tender text
Z1 actuator for motorized zone valves (opened)
With auxiliary microswitch.
UL873, cULus Listed & CE. UL 1995 sec.18 air plenums and ducts.U.S. Patent 7,048,251. Normally open actuators fit on Z2 valves only. Easy pushbutton attachment 7/8" knockout for 1/2" conduit connector. Rating of auxiliary switch contacts: 24 VAC: 0.0 A min, 0.4 A max. (24 V). 120 and Z111900 VAC: 0.25 A min, 5.0 A max. (230 V). Conduit connector size:1/2". Electric supply: 120 V (AC). Power consumption at full capacity: 7 VA.
|