ThermoSetter™, Thermal balancing valve with thermal disinfection bypass cartridge (press)
Product Description
Thermal balancing valve with thermal disinfection bypass cartridge (press)
Features union connections.
For domestic hot water recirculation circuits.
Includes bypass cartridge.
Technical data
Maximum operating pressure:
230 psi
Adjustment temperature range:
95 - 140 °F
Download
Drawings and specifications
Code | Primary Connection | Max Cv | Min Cv |
---|---|---|---|
116240AC 006 | 1/2" press union |
4.4 gpm | 1.0 gpm |
Design Cv
1.9 gpm
|
Disinfection Cv
2.3 gpm
|
||
3D models
Tender text
Thermal balancing valve with thermal disinfection bypass cartridge (press)
Features union connections.
For domestic hot water recirculation circuits.
Includes bypass cartridge.
Primary Connection: 1/2", press union. Maximum operating pressure: 230 psi. Adjustment temperature range: 95 - 140 °F. Max Cv: 4.4 gpm. Min Cv: 1.0 gpm. Design Cv: 1.9 gpm. Disinfection Cv: 2.3 gpm.
|
|||
116240AC 106 | 1/2" press union |
4.4 gpm | 1.0 gpm |
Design Cv
1.9 gpm
|
Disinfection Cv
2.3 gpm
|
||
3D models
Tender text
Thermal balancing valve with thermal disinfection bypass cartridge (press)
Features union connections.
For domestic hot water recirculation circuits.
Includes bypass cartridge.
Primary Connection: 1/2", press union. Maximum operating pressure: 230 psi. Adjustment temperature range: 95 - 140 °F. Max Cv: 4.4 gpm. Min Cv: 1.0 gpm. Design Cv: 1.9 gpm. Disinfection Cv: 2.3 gpm.
|
|||
116250AC 006 | 4.4 gpm | 1.0 gpm | 1.9 gpm |
Disinfection Cv
2.3 gpm
|
|||
3D models
Tender text
Thermal balancing valve with thermal disinfection bypass cartridge (press)
Features union connections.
For domestic hot water recirculation circuits.
Includes bypass cartridge.
Maximum operating pressure: 230 psi. Adjustment temperature range: 95 - 140 °F. Max Cv: 4.4 gpm. Min Cv: 1.0 gpm. Design Cv: 1.9 gpm. Disinfection Cv: 2.3 gpm.
|
|||
116250AC 106 | 3/4" press union |
4.4 gpm | 1.0 gpm |
Design Cv
1.9 gpm
|
Disinfection Cv
2.3 gpm
|
||
3D models
Tender text
Thermal balancing valve with thermal disinfection bypass cartridge (press)
Features union connections.
For domestic hot water recirculation circuits.
Includes bypass cartridge.
Primary Connection: 3/4", press union. Maximum operating pressure: 230 psi. Adjustment temperature range: 95 - 140 °F. Max Cv: 4.4 gpm. Min Cv: 1.0 gpm. Design Cv: 1.9 gpm. Disinfection Cv: 2.3 gpm.
|
|||
116640AC 006 | 1/2" press union |
4.4 gpm | 1.0 gpm |
Design Cv
1.9 gpm
|
Disinfection Cv
2.3 gpm
|
||
3D models
Tender text
Thermal balancing valve with thermal disinfection bypass cartridge (press)
Features union connections.
For domestic hot water recirculation circuits.
Includes bypass cartridge.
Primary Connection: 1/2", press union. Maximum operating pressure: 230 psi. Adjustment temperature range: 95 - 140 °F. Max Cv: 4.4 gpm. Min Cv: 1.0 gpm. Design Cv: 1.9 gpm. Disinfection Cv: 2.3 gpm.
|
|||
116640AC 106 | 1/2" press union |
4.4 gpm | 1.0 gpm |
Design Cv
1.9 gpm
|
Disinfection Cv
2.3 gpm
|
||
3D models
Tender text
Thermal balancing valve with thermal disinfection bypass cartridge (press)
Features union connections.
For domestic hot water recirculation circuits.
Includes bypass cartridge.
Primary Connection: 1/2", press union. Maximum operating pressure: 230 psi. Adjustment temperature range: 95 - 140 °F. Max Cv: 4.4 gpm. Min Cv: 1.0 gpm. Design Cv: 1.9 gpm. Disinfection Cv: 2.3 gpm.
|
|||
116650AC 006 | 3/4" press union |
4.4 gpm | 1.0 gpm |
Design Cv
1.9 gpm
|
Disinfection Cv
2.3 gpm
|
||
3D models
Tender text
Thermal balancing valve with thermal disinfection bypass cartridge (press)
Features union connections.
For domestic hot water recirculation circuits.
Includes bypass cartridge.
Primary Connection: 3/4", press union. Maximum operating pressure: 230 psi. Adjustment temperature range: 95 - 140 °F. Max Cv: 4.4 gpm. Min Cv: 1.0 gpm. Design Cv: 1.9 gpm. Disinfection Cv: 2.3 gpm.
|
|||
116650AC 106 | 3/4" press union |
4.4 gpm | 1.0 gpm |
Design Cv
1.9 gpm
|
Disinfection Cv
2.3 gpm
|
||
3D models
Tender text
Thermal balancing valve with thermal disinfection bypass cartridge (press)
Features union connections.
For domestic hot water recirculation circuits.
Includes bypass cartridge.
Primary Connection: 3/4", press union. Maximum operating pressure: 230 psi. Adjustment temperature range: 95 - 140 °F. Max Cv: 4.4 gpm. Min Cv: 1.0 gpm. Design Cv: 1.9 gpm. Disinfection Cv: 2.3 gpm.
|