ThermoSetter™, Thermal balancing valve (thermal disinfection using actuator)
Product Description
Thermal balancing valve (thermal disinfection using actuator)
Adjustable thermal balancing valve for domestic hot water recirculation circuits.
With by-pass valve for thermal disinfection. Purchase 656 actuator separately. Drywell includes temperature gauge.
Optional outlet check valve.
Adjustment temperature range: 95°F —150°F for the 1" and 1-1/4" only. The smaller ones have a top range of 140°F.
1/2" and 3/4" models: Cv max.: 2.1; Cv min: 0.23. Cv disinfection: 1.2; Cv design: 0.52. 1" and 1 1/4" models: Cv max.: 4.4; Cv min: 1.0. Cv disinfection: 2.3; Cv design: 1.9.
Technical data
Maximum operating pressure:
230 psi
Adjustment temperature range:
95–150 °F
Download
Drawings and specifications
Part number | Connection | Note | Max Cv |
---|---|---|---|
116360A | 1" FNPT |
Gauge | 4.4 |
Min Cv
1.0
|
Design Cv
1.9
|
Disinfection Cv
2.3
|
|
3D models
Tender text
Thermal balancing valve (thermal disinfection using actuator)
Adjustable thermal balancing valve for domestic hot water recirculation circuits.
With by-pass valve for thermal disinfection. Purchase 656 actuator separately. Drywell includes temperature gauge. Optional outlet check valve. Adjustment temperature range: 95°F —150°F for the 1" and 1-1/4" only. The smaller ones have a top range of 140°F. 1/2" and 3/4" models: Cv max.: 2.1; Cv min: 0.23. Cv disinfection: 1.2; Cv design: 0.52. 1" and 1 1/4" models: Cv max.: 4.4; Cv min: 1.0. Cv disinfection: 2.3; Cv design: 1.9. connection: 1" FNPT. Maximum operating pressure: 230 psi. Adjustment temperature range: 95–150 °F. Max Cv: 4.4. Min Cv: 1.0. Design Cv: 1.9. Disinfection Cv: 2.3.
|
|||
116360AC | 1" FNPT |
Check, gauge | 4.4 |
Min Cv
1.0
|
Design Cv
1.9
|
Disinfection Cv
2.3
|
|
3D models
Tender text
Thermal balancing valve (thermal disinfection using actuator)
Adjustable thermal balancing valve for domestic hot water recirculation circuits.
With by-pass valve for thermal disinfection. Purchase 656 actuator separately. Drywell includes temperature gauge. Optional outlet check valve. Adjustment temperature range: 95°F —150°F for the 1" and 1-1/4" only. The smaller ones have a top range of 140°F. 1/2" and 3/4" models: Cv max.: 2.1; Cv min: 0.23. Cv disinfection: 1.2; Cv design: 0.52. 1" and 1 1/4" models: Cv max.: 4.4; Cv min: 1.0. Cv disinfection: 2.3; Cv design: 1.9. connection: 1" FNPT. Maximum operating pressure: 230 psi. Adjustment temperature range: 95–150 °F. Max Cv: 4.4. Min Cv: 1.0. Design Cv: 1.9. Disinfection Cv: 2.3.
|
|||
116370A | 1 1/4" FNPT |
Gauge | 4.4 |
Min Cv
1.0
|
Design Cv
1.9
|
Disinfection Cv
2.3
|
|
3D models
Tender text
Thermal balancing valve (thermal disinfection using actuator)
Adjustable thermal balancing valve for domestic hot water recirculation circuits.
With by-pass valve for thermal disinfection. Purchase 656 actuator separately. Drywell includes temperature gauge. Optional outlet check valve. Adjustment temperature range: 95°F —150°F for the 1" and 1-1/4" only. The smaller ones have a top range of 140°F. 1/2" and 3/4" models: Cv max.: 2.1; Cv min: 0.23. Cv disinfection: 1.2; Cv design: 0.52. 1" and 1 1/4" models: Cv max.: 4.4; Cv min: 1.0. Cv disinfection: 2.3; Cv design: 1.9. connection: 1 1/4" FNPT. Maximum operating pressure: 230 psi. Adjustment temperature range: 95–150 °F. Max Cv: 4.4. Min Cv: 1.0. Design Cv: 1.9. Disinfection Cv: 2.3.
|
|||
116370AC | 1 1/4" FNPT |
Check, gauge | 4.4 |
Min Cv
1.0
|
Design Cv
1.9
|
Disinfection Cv
2.3
|
|
3D models
Tender text
Thermal balancing valve (thermal disinfection using actuator)
Adjustable thermal balancing valve for domestic hot water recirculation circuits.
With by-pass valve for thermal disinfection. Purchase 656 actuator separately. Drywell includes temperature gauge. Optional outlet check valve. Adjustment temperature range: 95°F —150°F for the 1" and 1-1/4" only. The smaller ones have a top range of 140°F. 1/2" and 3/4" models: Cv max.: 2.1; Cv min: 0.23. Cv disinfection: 1.2; Cv design: 0.52. 1" and 1 1/4" models: Cv max.: 4.4; Cv min: 1.0. Cv disinfection: 2.3; Cv design: 1.9. connection: 1 1/4" FNPT. Maximum operating pressure: 230 psi. Adjustment temperature range: 95–150 °F. Max Cv: 4.4. Min Cv: 1.0. Design Cv: 1.9. Disinfection Cv: 2.3.
|