ThermoSetter™, Thermal balancing valve for thermal disinfection using electronic actuator (PEX)
Product Description
Thermal balancing valve for thermal disinfection using electronic actuator (PEX)
Features union connections.
Standard with outlet check valve.
For domestic hot water recirculation circuits.
With by-pass valve for thermal disinfection.
Temperature gauge included.
Actuator bypass.
Drywell for temperature gauge or probe.
Technical data
Maximum operating pressure:
230 psi
Adjustment temperature range:
95 – 140 °F
Note
Purchase 656 actuator separately.
Download
Drawings and specifications
Part number | Primary Connection | Max Cv | Min Cv |
---|---|---|---|
116340AC 007 | 1/2" PEX crimp union |
2.1 gpm | 0.23 gpm |
Design Cv
0.52 gpm
|
Disinfection Cv
1.2 gpm
|
||
3D models
Tender text
Thermal balancing valve for thermal disinfection using electronic actuator (PEX)
Features union connections.
Standard with outlet check valve.
For domestic hot water recirculation circuits.
With by-pass valve for thermal disinfection.
Temperature gauge included.
Actuator bypass.
Drywell for temperature gauge or probe.
Primary Connection: 1/2", PEX crimp union. Maximum operating pressure: 230 psi. Adjustment temperature range: 95 – 140 °F. Max Cv: 2.1 gpm. Min Cv: 0.23 gpm. Design Cv: 0.52 gpm. Disinfection Cv: 1.2 gpm.
|
|||
116340AC 008 | 1/2" PEX expansion union |
2.1 gpm | 0.23 gpm |
Design Cv
0.52 gpm
|
Disinfection Cv
1.2 gpm
|
||
3D models
Tender text
Thermal balancing valve for thermal disinfection using electronic actuator (PEX)
Features union connections.
Standard with outlet check valve.
For domestic hot water recirculation circuits.
With by-pass valve for thermal disinfection.
Temperature gauge included.
Actuator bypass.
Drywell for temperature gauge or probe.
Primary Connection: 1/2", PEX expansion union. Maximum operating pressure: 230 psi. Adjustment temperature range: 95 – 140 °F. Max Cv: 2.1 gpm. Min Cv: 0.23 gpm. Design Cv: 0.52 gpm. Disinfection Cv: 1.2 gpm.
|
|||
116340AC 107 | 1/2" PEX crimp union |
2.1 gpm | 0.23 gpm |
Design Cv
0.52 gpm
|
Disinfection Cv
1.2 gpm
|
||
3D models
Tender text
Thermal balancing valve for thermal disinfection using electronic actuator (PEX)
Features union connections.
Standard with outlet check valve.
For domestic hot water recirculation circuits.
With by-pass valve for thermal disinfection.
Temperature gauge included.
Actuator bypass.
Drywell for temperature gauge or probe.
Primary Connection: 1/2", PEX crimp union. Maximum operating pressure: 230 psi. Adjustment temperature range: 95 – 140 °F. Max Cv: 2.1 gpm. Min Cv: 0.23 gpm. Design Cv: 0.52 gpm. Disinfection Cv: 1.2 gpm.
|
|||
116340AC 108 | 1/2" PEX expansion union |
2.1 gpm | 0.23 gpm |
Design Cv
0.52 gpm
|
Disinfection Cv
1.2 gpm
|
||
3D models
Tender text
Thermal balancing valve for thermal disinfection using electronic actuator (PEX)
Features union connections.
Standard with outlet check valve.
For domestic hot water recirculation circuits.
With by-pass valve for thermal disinfection.
Temperature gauge included.
Actuator bypass.
Drywell for temperature gauge or probe.
Primary Connection: 1/2", PEX expansion union. Maximum operating pressure: 230 psi. Adjustment temperature range: 95 – 140 °F. Max Cv: 2.1 gpm. Min Cv: 0.23 gpm. Design Cv: 0.52 gpm. Disinfection Cv: 1.2 gpm.
|
|||
116350AC 007 | 3/4" PEX crimp union |
2.1 gpm | 0.23 gpm |
Design Cv
0.52 gpm
|
Disinfection Cv
1.2 gpm
|
||
3D models
Tender text
Thermal balancing valve for thermal disinfection using electronic actuator (PEX)
Features union connections.
Standard with outlet check valve.
For domestic hot water recirculation circuits.
With by-pass valve for thermal disinfection.
Temperature gauge included.
Actuator bypass.
Drywell for temperature gauge or probe.
Primary Connection: 3/4", PEX crimp union. Maximum operating pressure: 230 psi. Adjustment temperature range: 95 – 140 °F. Max Cv: 2.1 gpm. Min Cv: 0.23 gpm. Design Cv: 0.52 gpm. Disinfection Cv: 1.2 gpm.
|
|||
116350AC 008 | 3/4" PEX expansion union |
2.1 gpm | 0.23 gpm |
Design Cv
0.52 gpm
|
Disinfection Cv
1.2 gpm
|
||
3D models
Tender text
Thermal balancing valve for thermal disinfection using electronic actuator (PEX)
Features union connections.
Standard with outlet check valve.
For domestic hot water recirculation circuits.
With by-pass valve for thermal disinfection.
Temperature gauge included.
Actuator bypass.
Drywell for temperature gauge or probe.
Primary Connection: 3/4", PEX expansion union. Maximum operating pressure: 230 psi. Adjustment temperature range: 95 – 140 °F. Max Cv: 2.1 gpm. Min Cv: 0.23 gpm. Design Cv: 0.52 gpm. Disinfection Cv: 1.2 gpm.
|
|||
116350AC 107 | 3/4" PEX crimp union |
2.1 gpm | 0.23 gpm |
Design Cv
0.52 gpm
|
Disinfection Cv
1.2 gpm
|
||
3D models
Tender text
Thermal balancing valve for thermal disinfection using electronic actuator (PEX)
Features union connections.
Standard with outlet check valve.
For domestic hot water recirculation circuits.
With by-pass valve for thermal disinfection.
Temperature gauge included.
Actuator bypass.
Drywell for temperature gauge or probe.
Primary Connection: 3/4", PEX crimp union. Maximum operating pressure: 230 psi. Adjustment temperature range: 95 – 140 °F. Max Cv: 2.1 gpm. Min Cv: 0.23 gpm. Design Cv: 0.52 gpm. Disinfection Cv: 1.2 gpm.
|
|||
116350AC 108 | 3/4" PEX expansion union |
2.1 gpm | 0.23 gpm |
Design Cv
0.52 gpm
|
Disinfection Cv
1.2 gpm
|
||
3D models
Tender text
Thermal balancing valve for thermal disinfection using electronic actuator (PEX)
Features union connections.
Standard with outlet check valve.
For domestic hot water recirculation circuits.
With by-pass valve for thermal disinfection.
Temperature gauge included.
Actuator bypass.
Drywell for temperature gauge or probe.
Primary Connection: 3/4", PEX expansion union. Maximum operating pressure: 230 psi. Adjustment temperature range: 95 – 140 °F. Max Cv: 2.1 gpm. Min Cv: 0.23 gpm. Design Cv: 0.52 gpm. Disinfection Cv: 1.2 gpm.
|