Series 7002

User module with heat meter template.

User module with heat meter template.
User module with heat meter template.
User module with heat meter template.
User module with heat meter template.
Download high resolution

Product Description

User module with heat meter template.
Complete with:
- 2 pairs of 3/4" M ball valves;
- pressure independent control valve with presetting;
- technopolymer template for flow meter (T max. 55 °C);
- inspectable strainer with probe connection;
- technopolymer mounting bracket.
To be coupled with thermo-electric actuators 6565/6566 series.

Technical data

Medium temperature range: 3–90 °C

Drawings and specifications

Part number Flow rate regulation range Actions
700255 H20 0,02–0,20 m³/h
2D drawings
3D models
Tender text
CALEFFI, 700255 H20. User module with heat meter template. Complete with: - 2 pairs of 3/4" M ball valves; - pressure independent control valve with presetting; - technopolymer template for flow meter (T max. 55 °C); - inspectable strainer with probe connection; - technopolymer mounting bracket. To be coupled with thermo-electric actuators 6565/6566 series. Medium temperature range: 3–90 °C. Flow rate regulation range: 0,02–0,20 m³/h.
SCIP code
d1ab1c59-b41a-4b05-9bef-4fff94382ae1
700255 1H2 0,12–1,20 m³/h
2D drawings
3D models
Tender text
CALEFFI, 700255 1H2. User module with heat meter template. Complete with: - 2 pairs of 3/4" M ball valves; - pressure independent control valve with presetting; - technopolymer template for flow meter (T max. 55 °C); - inspectable strainer with probe connection; - technopolymer mounting bracket. To be coupled with thermo-electric actuators 6565/6566 series. Medium temperature range: 3–90 °C. Flow rate regulation range: 0,12–1,20 m³/h.
SCIP code
15c77822-72e6-483d-96c3-93bb7339ade1
700255 H40 0,08–0,40 m³/h
2D drawings
3D models
Tender text
CALEFFI, 700255 H40. User module with heat meter template. Complete with: - 2 pairs of 3/4" M ball valves; - pressure independent control valve with presetting; - technopolymer template for flow meter (T max. 55 °C); - inspectable strainer with probe connection; - technopolymer mounting bracket. To be coupled with thermo-electric actuators 6565/6566 series. Medium temperature range: 3–90 °C. Flow rate regulation range: 0,08–0,40 m³/h.
SCIP code
9c82b4de-d5ef-448f-97d9-9d84e913b651

Applications

Pipe Sizer Caleffi

This application allows for sizing and making calculations for pipes and conduits carrying water or air, respectively for hydraulic or aeraulic plants.