Solenoid valve for gas, normally closed, with manual reset.
Class A - Group 2.

Technical data

Protection class: IP 65
Maximum working pressure: 500 mbar

Certifications

CE

Drawings and specifications

Part number Connection Electric supply Actions
837005 Rp 3/4" (EN 10226-1) F
230 V AC
3D models
Tender text
CALEFFI, 837005. Solenoid valve for gas, normally closed, with manual reset. Class A - Group 2. Connection: Rp 3/4" (EN 10226-1) F. Maximum working pressure: 500 mbar. Electric supply: 230 V AC. Protection class: IP 65.
SCIP code
5a64e3ec-aac5-49b5-870a-8722ed1e8bdd
837006 Rp 1" (EN 10226-1) F
230 V AC
3D models
Tender text
CALEFFI, 837006. Solenoid valve for gas, normally closed, with manual reset. Class A - Group 2. Connection: Rp 1" (EN 10226-1) F. Maximum working pressure: 500 mbar. Electric supply: 230 V AC. Protection class: IP 65.
SCIP code
5a64e3ec-aac5-49b5-870a-8722ed1e8bdd
837007 Rp 1 1/4" (EN 10226-1) F
230 V AC
3D models
Tender text
CALEFFI, 837007. Solenoid valve for gas, normally closed, with manual reset. Class A - Group 2. Connection: Rp 1 1/4" (EN 10226-1) F. Maximum working pressure: 500 mbar. Electric supply: 230 V AC. Protection class: IP 65.
SCIP code
5a64e3ec-aac5-49b5-870a-8722ed1e8bdd
837008 Rp 1 1/2" (EN 10226-1) F
230 V AC
2D drawings
3D models
Tender text
CALEFFI, 837008. Solenoid valve for gas, normally closed, with manual reset. Class A - Group 2. Connection: Rp 1 1/2" (EN 10226-1) F. Maximum working pressure: 500 mbar. Electric supply: 230 V AC. Protection class: IP 65.
SCIP code
5a64e3ec-aac5-49b5-870a-8722ed1e8bdd
837009 Rp 2" (EN 10226-1) F
230 V AC
3D models
Tender text
CALEFFI, 837009. Solenoid valve for gas, normally closed, with manual reset. Class A - Group 2. Connection: Rp 2" (EN 10226-1) F. Maximum working pressure: 500 mbar. Electric supply: 230 V AC. Protection class: IP 65.
SCIP code
5a64e3ec-aac5-49b5-870a-8722ed1e8bdd
837105 Rp 3/4" (EN 10226-1) F
24 V AC
3D models
Tender text
CALEFFI, 837105. Solenoid valve for gas, normally closed, with manual reset. Class A - Group 2. Connection: Rp 3/4" (EN 10226-1) F. Maximum working pressure: 500 mbar. Electric supply: 24 V AC. Protection class: IP 65.
SCIP code
5a64e3ec-aac5-49b5-870a-8722ed1e8bdd
837106 Rp 1" (EN 10226-1) F
24 V AC
3D models
Tender text
CALEFFI, 837106. Solenoid valve for gas, normally closed, with manual reset. Class A - Group 2. Connection: Rp 1" (EN 10226-1) F. Maximum working pressure: 500 mbar. Electric supply: 24 V AC. Protection class: IP 65.
SCIP code
5a64e3ec-aac5-49b5-870a-8722ed1e8bdd
837107 Rp 1 1/4" (EN 10226-1) F
24 V AC
3D models
Tender text
CALEFFI, 837107. Solenoid valve for gas, normally closed, with manual reset. Class A - Group 2. Connection: Rp 1 1/4" (EN 10226-1) F. Maximum working pressure: 500 mbar. Electric supply: 24 V AC. Protection class: IP 65.
SCIP code
5a64e3ec-aac5-49b5-870a-8722ed1e8bdd
837108 Rp 1 1/2" (EN 10226-1) F
24 V AC
2D drawings
3D models
Tender text
CALEFFI, 837108. Solenoid valve for gas, normally closed, with manual reset. Class A - Group 2. Connection: Rp 1 1/2" (EN 10226-1) F. Maximum working pressure: 500 mbar. Electric supply: 24 V AC. Protection class: IP 65.
SCIP code
5a64e3ec-aac5-49b5-870a-8722ed1e8bdd
837109 Rp 2" (EN 10226-1) F
24 V AC
3D models
Tender text
CALEFFI, 837109. Solenoid valve for gas, normally closed, with manual reset. Class A - Group 2. Connection: Rp 2" (EN 10226-1) F. Maximum working pressure: 500 mbar. Electric supply: 24 V AC. Protection class: IP 65.
SCIP code
5a64e3ec-aac5-49b5-870a-8722ed1e8bdd
837205 Rp 3/4" (EN 10226-1) F
12 V DC
3D models
Tender text
CALEFFI, 837205. Solenoid valve for gas, normally closed, with manual reset. Class A - Group 2. Connection: Rp 3/4" (EN 10226-1) F. Maximum working pressure: 500 mbar. Electric supply: 12 V DC. Protection class: IP 65.
SCIP code
5a64e3ec-aac5-49b5-870a-8722ed1e8bdd
837206 Rp 1" (EN 10226-1) F
12 V DC
3D models
Tender text
CALEFFI, 837206. Solenoid valve for gas, normally closed, with manual reset. Class A - Group 2. Connection: Rp 1" (EN 10226-1) F. Maximum working pressure: 500 mbar. Electric supply: 12 V DC. Protection class: IP 65.
SCIP code
5a64e3ec-aac5-49b5-870a-8722ed1e8bdd
837207 Rp 1 1/4" (EN 10226-1) F
12 V DC
3D models
Tender text
CALEFFI, 837207. Solenoid valve for gas, normally closed, with manual reset. Class A - Group 2. Connection: Rp 1 1/4" (EN 10226-1) F. Maximum working pressure: 500 mbar. Electric supply: 12 V DC. Protection class: IP 65.
SCIP code
5a64e3ec-aac5-49b5-870a-8722ed1e8bdd
837208 Rp 1 1/2" (EN 10226-1) F
12 V DC
2D drawings
3D models
Tender text
CALEFFI, 837208. Solenoid valve for gas, normally closed, with manual reset. Class A - Group 2. Connection: Rp 1 1/2" (EN 10226-1) F. Maximum working pressure: 500 mbar. Electric supply: 12 V DC. Protection class: IP 65.
SCIP code
5a64e3ec-aac5-49b5-870a-8722ed1e8bdd
837209 Rp 2" (EN 10226-1) F
12 V DC
3D models
Tender text
CALEFFI, 837209. Solenoid valve for gas, normally closed, with manual reset. Class A - Group 2. Connection: Rp 2" (EN 10226-1) F. Maximum working pressure: 500 mbar. Electric supply: 12 V DC. Protection class: IP 65.
SCIP code
5a64e3ec-aac5-49b5-870a-8722ed1e8bdd

Applications

Pipe Sizer Caleffi

This application allows for sizing and making calculations for pipes and conduits carrying water or air, respectively for hydraulic or aeraulic plants.