Pump station for solar thermal systems, flow and return connection.
Product Description
Pump station for solar thermal systems, flow and return connection.
Complete with:
- Solar circulation pump;
- 253 series safety relief valve for solar thermal systems;
- filler/drain cock;
- instrument holder fitting with pressure gauge;
- flow meter;
- return temperature gauge;
- shut-off and check valve;
- 2 hose connections.
Set up for connection to DeltaSol® SLL digital regulator.
(For other settings refer to 253 series using adapter code F21224).
With PWM control.
With insulation.
Technical data
Maximum working pressure:
10 bar
Medium temperature range:
-10–110 °C
Electric supply:
230 V AC
Maximum percentage of glycol:
50 %
Medium:
glycol solutions, water
Type of pump:
UPM3 15-75
Certifications
Download
Drawings and specifications
Part number | Connection | Flow meter scale | |
---|---|---|---|
279050HE | G 3/4" (ISO 228-1) F |
1–13 l/min | |
2D drawings
3D models
Tender text
Pump station for solar thermal systems, flow and return connection. With insulation.
Complete with:
- Solar circulation pump;
- 253 series safety relief valve for solar thermal systems;
- filler/drain cock;
- instrument holder fitting with pressure gauge;
- flow meter;
- return temperature gauge;
- shut-off and check valve;
- 2 hose connections.
Set up for connection to DeltaSol® SLL digital regulator.
(For other settings refer to 253 series using adapter code F21224).
With PWM control. Connection: G 3/4" (ISO 228-1) F. Maximum working pressure: 10 bar. Medium temperature range: -10–110 °C. Electric supply: 230 V AC. Maximum percentage of glycol: 50 %. Medium: glycol solutions, water. Flow meter scale: 1–13 l/min. Type of pump: UPM3 15-75.
SCIP code
d3b282e0-4498-4607-be32-20384bc9fddd
|
|||
279052HE | G 3/4" (ISO 228-1) F |
8–30 l/min | |
3D models
Tender text
Pump station for solar thermal systems, flow and return connection. With insulation.
Complete with:
- Solar circulation pump;
- 253 series safety relief valve for solar thermal systems;
- filler/drain cock;
- instrument holder fitting with pressure gauge;
- flow meter;
- return temperature gauge;
- shut-off and check valve;
- 2 hose connections.
Set up for connection to DeltaSol® SLL digital regulator.
(For other settings refer to 253 series using adapter code F21224).
With PWM control. Connection: G 3/4" (ISO 228-1) F. Maximum working pressure: 10 bar. Medium temperature range: -10–110 °C. Electric supply: 230 V AC. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions. Flow meter scale: 8–30 l/min. Type of pump: UPM3 15-75.
SCIP code
7877bb65-7084-453d-a433-837723613c2b
|