Technical data

Maximum working pressure: 10 bar
Medium temperature range: 5–80 °C
Outlet centre distance: 50 mm

Drawings and specifications

Part number Connection Connection Outlet connection
3D models
Tender text
Pair of manifolds. Complete with: - return manifold with built-in shut-off valves fitted for thermo-electric actuator; - flow manifold with micrometric preregulating valves. Connection: G 1" (ISO 228-1) F, inlet. Connection: G 1" A (ISO 228-1) M, end outlet. outlet connection: G 3/4" A (ISO 228-1) M, 2 outlets. Maximum working pressure: 10 bar. Medium temperature range: 5–80 °C. Outlet centre distance: 50 mm.
SCIP code
13cc9c6a-d7ee-468c-b098-63250c66ffe3
3D models
Tender text
Pair of manifolds. Complete with: - return manifold with built-in shut-off valves fitted for thermo-electric actuator; - flow manifold with micrometric preregulating valves. Connection: G 1" (ISO 228-1) F, inlet. Connection: G 1" A (ISO 228-1) M, end outlet. outlet connection: G 3/4" A (ISO 228-1) M, 3 outlets. Maximum working pressure: 10 bar. Medium temperature range: 5–80 °C. Outlet centre distance: 50 mm.
SCIP code
b6666837-2c6c-4b60-9396-3bd996e14e16
3D models
Tender text
Pair of manifolds. Complete with: - return manifold with built-in shut-off valves fitted for thermo-electric actuator; - flow manifold with micrometric preregulating valves. Connection: G 1" (ISO 228-1) F, inlet. Connection: G 1" A (ISO 228-1) M, end outlet. outlet connection: G 3/4" A (ISO 228-1) M, 4 outlets. Maximum working pressure: 10 bar. Medium temperature range: 5–80 °C. Outlet centre distance: 50 mm.
SCIP code
e7baa215-2311-477f-828f-932982338362
3D models
Download
Download
Tender text
Pair of manifolds. Complete with: - return manifold with built-in shut-off valves fitted for thermo-electric actuator; - flow manifold with micrometric preregulating valves. Connection: G 1" (ISO 228-1) F, inlet. Connection: G 1" A (ISO 228-1) M, end outlet. outlet connection: G 3/4" A (ISO 228-1) M, 5 outlets. Maximum working pressure: 10 bar. Medium temperature range: 5–80 °C. Outlet centre distance: 50 mm.
SCIP code
a29a6a40-5fb0-4393-a91b-0faafa710958
3D models
Tender text
Pair of manifolds. Complete with: - return manifold with built-in shut-off valves fitted for thermo-electric actuator; - flow manifold with micrometric preregulating valves. Connection: G 1" (ISO 228-1) F, inlet. Connection: G 1" A (ISO 228-1) M, end outlet. outlet connection: G 3/4" A (ISO 228-1) M, 6 outlets. Maximum working pressure: 10 bar. Medium temperature range: 5–80 °C. Outlet centre distance: 50 mm.
SCIP code
b65a4368-a18a-48a4-8d84-b7ad499fcfbd

Applications

DWS

Caleffi Domestic Water Sizer allows fast and correct sizing of the main components of domestic water systems.

Pipe Sizer Caleffi
Pipe Sizer Caleffi

This application allows for sizing and making calculations for pipes and conduits carrying water or air, respectively for hydraulic or aeraulic plants.

Scroll