Real installations: Ritz Carlton, Riyadh

Date

Hydronic products are mostly concealed, either within walls or in heating plant compartments. However, they are essential for guaranteeing comfortable conditions in the living spaces we inhabit daily, year-round.

That is the reason why it's important to show you where our products where chosen and installed.


A reference list and more detailed cases here


Today we would like to draw attention to the prestigious project of the Ritz Carlton Riyadh in Saudi Arabia. 

CONSTRUCTION SITE 

492 between guest rooms and suites, 62,000 square feet of event space, a gentlemen’s-only spa, a majestic indoor heated pool, restaurants. 

 

INSTALLATION DETAILS

In this luxury hotel the regulation of the domestic water temperature and the management of the thermal disinfection of the whole system is entrusted to six flanged electronic mixing valves LEGIOMIX  6000 series. This choice has been taken with the aim to maximize both the comfort level and the guaranteed safety of all the guests. 

Six separate water distribution areas supply domestic hot water to the whole structure including rooms, suites, common areas, pool and SPA. Each 6000 series LEGIOMIX unit may have different settings depending on the area it is dedicated to. Each unit, furthermore, is set to carry the thermal disinfection of the system with scheduled timing and temperature. This way the users are protected from Legionella bacteria and the system is considered safe. All the settings may be easily changed acting directly on the digital regulator, which provides/allows the historic data and parameters download. 

Due to this high-tech system, Ritz-Carlton can be proud of the level of care it offers to its guests.

 

 PRODUCT FEATURES

The electronic mixing valve is used in centralised systems that produce and distribute domestic hot water.

It guarantees and maintains the temperature of the domestic hot water delivered to the user when there are variations in the temperature and pressure of the hot and cold water at the inlet or in the draw-off flow rate.

This particular Caleffi product is equipped with a specific regulator that controls a set of programs for circuit thermal disinfection against Legionella.

It also enables checking the temperature and time for thermal disinfection are actually reached and undertaking the appropriate corrective action. All the parameters are updated every day and logged, with temperatures recorded every hour.

Depending on the system type and user habits, it is possible to program temperature levels and operation times in the most appropriate manner.

Last, it is fitted for a monitoring and remote control connection.