Series 7507G

CONTECA® EASY ULTRA, Direct heat meter for heating and cooling systems(*).

Go to
750705G.png
Download high resolution

Product Description

Direct heat meter for heating and cooling systems(*).
Complete with:
- electronic integrator with LCD display
- pair of immersion temperature probes;
- ultrasonic volume meter with pulse output;
- 2 pulse inputs for DHW and DCW.
Upgradable with configuration options to be ordered together (*).

Technical data

Communication protocol: M-Bus on RS485
Accuracy class: 2
Nominal pressure: PN 16
Probe/cable length: 1 m
Protection class: IP 54
Running power consumption: 1 W
Electric supply: 24 V AC
Medium temperature range: 2–90 °C

Certifications

CE
MI004

Drawings and specifications

Part number Connection Permanent flow rate (Qp) Minimum flow rate (Qi)
2D drawings
Download
Download
3D models
Download
Tender text
CALEFFI, 750705G, CONTECA® EASY ULTRA. Direct heat meter for heating and cooling systems(*). Complete with: - electronic integrator with LCD display - pair of immersion temperature probes; - ultrasonic volume meter with pulse output; - 2 pulse inputs for DHW and DCW. Upgradable with configuration options to be ordered together (*). Connection: G 1" A (ISO 228-1) M. Medium temperature range: 2–90 °C. Electric supply: 24 V AC. Running power consumption: 1 W. Protection class: IP 54. Probe/cable length: 1 m. Nominal pressure: PN 16. Accuracy class: 2. Permanent flow rate (Qp): 2,5 m³/h. Minimum flow rate (Qi): 10 l/h. Communication protocol: M-Bus on RS485.
SCIP code
c337a869-4683-4db7-926d-149bc5192a24
2D drawings
Download
Download
3D models
Download
Tender text
CALEFFI, 750706G, CONTECA® EASY ULTRA. Direct heat meter for heating and cooling systems(*). Complete with: - electronic integrator with LCD display - pair of immersion temperature probes; - ultrasonic volume meter with pulse output; - 2 pulse inputs for DHW and DCW. Upgradable with configuration options to be ordered together (*). Connection: G 1 1/4" A (ISO 228-1) M. Medium temperature range: 2–90 °C. Electric supply: 24 V AC. Running power consumption: 1 W. Accuracy class: 2. Permanent flow rate (Qp): 3,5 m³/h. Minimum flow rate (Qi): 35 l/h.
SCIP code
CODE UNDER ANALYSIS
2D drawings
Download
Download
3D models
Download
Tender text
CALEFFI, 750707G, CONTECA® EASY ULTRA. Direct heat meter for heating and cooling systems(*). Complete with: - electronic integrator with LCD display - pair of immersion temperature probes; - ultrasonic volume meter with pulse output; - 2 pulse inputs for DHW and DCW. Upgradable with configuration options to be ordered together (*). Connection: G 1 1/2" A (ISO 228-1) M. Medium temperature range: 2–90 °C. Electric supply: 24 V AC. Running power consumption: 1 W. Accuracy class: 2. Permanent flow rate (Qp): 6 m³/h. Minimum flow rate (Qi): 24 l/h.
SCIP code
CODE UNDER ANALYSIS