Series 767

Motorised regulating unit DN 25, for heating and cooling systems.

Go to
767662HE2.png
767600HE_dim~-~page-1.png
767600HE_bol~-~page-1.png
767600HE_app~-~page-1.png
767662HE2.png
767600HE_dim~-~page-1.png
767600HE_bol~-~page-1.png
767600HE_app~-~page-1.png
Download high resolution

Product Description

Motorised regulating unit DN 25, for heating and cooling systems.
Factory configuration: upstream flow - supply on the RH side.
Complete with:
- high-efficiency pump;
- motorised mixing valve;
- designed for heat meter installation CONTECA EASY codes 750405G or 750705G.
RH to LH Convertible.
With insulation.
With auxiliary microswitch.

Technical data

Maximum working pressure: 10 bar
Medium temperature range: 5–90 °C
Outlet centre distance: 125 mm

Certifications

CE

Drawings and specifications

Part number Boiler side connection System side connection Electric supply
Control signal
3 point
2D drawings
Download
Download
3D models
Download
Download
Tender text
Motorised regulating unit DN 25, for heating and cooling systems. With insulation. With auxiliary microswitch. Factory configuration: upstream flow - supply on the RH side. Complete with: - high-efficiency pump; - motorised mixing valve; - designed for heat meter installation CONTECA EASY codes 750405G or 750705G. RH to LH Convertible. Boiler side connection: G 1" (ISO 228-1) F. System side connection: G 1 1/2" A (ISO 228-1) M. Maximum working pressure: 10 bar. Medium temperature range: 5–90 °C. Electric supply: 230 V AC. Control signal: 3 point. Outlet centre distance: 125 mm.
SCIP code
3bd77297-493c-4165-9e99-e0d535414066
Control signal
0–10 V
2D drawings
Download
Download
3D models
Download
Download
Tender text
Motorised regulating unit DN 25, for heating and cooling systems. With insulation. With auxiliary microswitch. Factory configuration: upstream flow - supply on the RH side. Complete with: - high-efficiency pump; - motorised mixing valve; - designed for heat meter installation CONTECA EASY codes 750405G or 750705G. RH to LH Convertible. Boiler side connection: G 1 1/2" A (ISO 228-1) M. System side connection: G 1" (ISO 228-1) F. Maximum working pressure: 10 bar. Medium temperature range: 5–90 °C. Electric supply: 24 V AC/DC. Control signal: 0–10 V. Outlet centre distance: 125 mm.
SCIP code
ef6162d5-5c29-4c0b-bf85-7600ba06404b

Applications

Pipe Sizer Caleffi
Pipe Sizer Caleffi

This application allows for sizing and making calculations for pipes and conduits carrying water or air, respectively for hydraulic or aeraulic plants.