Product Description

Controllable, reduced pressure zone backflow preventer, standard version.
Upstream of the backflow preventer is mandatory to install a strainer 577 series.
BA type.

Certified to EN 12729.

Technical data

Material: dezincification resistant brass DR "low lead"
Nominal pressure: PN 10
Medium temperature range: 5–65 °C
Differential operating pressure: 14 kPa
Low Lead

Certifications

ACS
BELGAQUA
DVGW DIN CERT
KIWA
NF
SVGW
VA1.57/19919
HY-CERT
RISE SC0933-09
PZH
KIWA UK

Drawings and specifications

Part number Connection Actions
574040 R 1/2" (EN 10226-1) M
union
2D drawings
Download
Download
3D models
Download
Download
Tender text
CALEFFI, 574040. Controllable, reduced pressure zone backflow preventer, standard version. Upstream of the backflow preventer is mandatory to install a strainer 577 series. BA type. Certified to EN 12729. Connection: R 1/2" (EN 10226-1) M, union. Differential operating pressure: 14 kPa. Medium temperature range: 5–65 °C. Nominal pressure: PN 10. Material: dezincification resistant brass DR "low lead".
SCIP code
cef39714-2227-43be-a0a5-294c7e1a2f75
574050 R 3/4" (EN 10226-1) M
union
2D drawings
Download
Download
3D models
Download
Download
Tender text
CALEFFI, 574050. Controllable, reduced pressure zone backflow preventer, standard version. Upstream of the backflow preventer is mandatory to install a strainer 577 series. BA type. Certified to EN 12729. Connection: R 3/4" (EN 10226-1) M, union. Differential operating pressure: 14 kPa. Medium temperature range: 5–65 °C. Nominal pressure: PN 10. Material: dezincification resistant brass DR "low lead".
SCIP code
60d20fba-f487-4370-b730-6a9284a799c4
574006 R 1" (EN 10226-1) M
union
2D drawings
Download
Download
3D models
Download
Download
Tender text
CALEFFI, 574006. Controllable, reduced pressure zone backflow preventer, standard version. Upstream of the backflow preventer is mandatory to install a strainer 577 series. BA type. Certified to EN 12729. Connection: R 1" (EN 10226-1) M, union. Differential operating pressure: 14 kPa. Medium temperature range: 5–65 °C. Nominal pressure: PN 10. Material: dezincification resistant brass DR "low lead".
SCIP code
3eacde51-5eef-490e-ba30-96a1d57cec2c

Applications

Pipe Sizer Caleffi
Pipe Sizer Caleffi