Series 574

Controllable, reduced pressure zone backflow preventer, standard version.

Controllable, reduced pressure zone backflow preventer, standard version.
Controllable, reduced pressure zone backflow preventer, standard version.
Controllable, reduced pressure zone backflow preventer, standard version.
Controllable, reduced pressure zone backflow preventer, standard version.
Controllable, reduced pressure zone backflow preventer, standard version.
Controllable, reduced pressure zone backflow preventer, standard version.
Controllable, reduced pressure zone backflow preventer, standard version.
Controllable, reduced pressure zone backflow preventer, standard version.
Download high resolution

Product Description

Controllable, reduced pressure zone backflow preventer, standard version.
Upstream of the backflow preventer is mandatory to install a strainer 577 series.
BA type.

Certified to EN 12729.

Technical data

Auxiliary Microswitch: NO
Battery included: NO
Electrical Components: No
Insulation: No
Material: dezincification resistant brass DR "low lead"
Nominal pressure: PN 10
Medium temperature range: 5–65 °C
Differential operating pressure: 14 kPa
Low Lead

Certifications

ACS
BELGAQUA
DVGW DIN CERT
KIWA
NF
SVGW
VA1.57/19919
HY-CERT
RISE SC0933-09
PZH
KIWA UK

Drawings and specifications

Part number Connection Actions
574040 R 1/2" (EN 10226-1) M
union
2D drawings
3D models
Tender text
CALEFFI, 574040. Controllable, reduced pressure zone backflow preventer, standard version. Upstream of the backflow preventer is mandatory to install a strainer 577 series. BA type. Certified to EN 12729. Connection: R 1/2" (EN 10226-1) M, union. Differential operating pressure: 14 kPa. Medium temperature range: 5–65 °C. Nominal pressure: PN 10. Material: dezincification resistant brass DR "low lead".
SCIP code
cef39714-2227-43be-a0a5-294c7e1a2f75
574050 R 3/4" (EN 10226-1) M
union
2D drawings
3D models
Tender text
CALEFFI, 574050. Controllable, reduced pressure zone backflow preventer, standard version. Upstream of the backflow preventer is mandatory to install a strainer 577 series. BA type. Certified to EN 12729. Connection: R 3/4" (EN 10226-1) M, union. Differential operating pressure: 14 kPa. Medium temperature range: 5–65 °C. Nominal pressure: PN 10. Material: dezincification resistant brass DR "low lead".
SCIP code
60d20fba-f487-4370-b730-6a9284a799c4
574006 R 1" (EN 10226-1) M
union
2D drawings
3D models
Tender text
CALEFFI, 574006. Controllable, reduced pressure zone backflow preventer, standard version. Upstream of the backflow preventer is mandatory to install a strainer 577 series. BA type. Certified to EN 12729. Connection: R 1" (EN 10226-1) M, union. Differential operating pressure: 14 kPa. Medium temperature range: 5–65 °C. Nominal pressure: PN 10. Material: dezincification resistant brass DR "low lead".
SCIP code
3eacde51-5eef-490e-ba30-96a1d57cec2c

Applications

Pipe Sizer Caleffi

This application allows for sizing and making calculations for pipes and conduits carrying water or air, respectively for hydraulic or aeraulic plants.