AUTOFLOW, Compact automatic flow rate regulator, in line, with high resistance polymer cartridge.

Go to
127151.png
127141_dim~-~page-1.png
127141_sez~-~page-1.png
127151.png
127141_dim~-~page-1.png
127141_sez~-~page-1.png
Show In 3D
Download high resolution

Product Description

Compact automatic flow rate regulator, in line, with high resistance polymer cartridge.
Flow rates: 0,02–0,06 m3/h - Δp range: 20–200 kPa - Accuracy: ± 15 %.
Flow rates: 0,085–11,0 m3/h - Δp range: 15–200 kPa - Accuracy: ± 10 %.
PATENT

Technical data

Maximum working pressure: 16 bar
Medium temperature range: 0–100 °C
Maximum percentage of glycol: 50 %
Medium: glycol solutions, water
Material: brass

Certifications

ACS
PZH

Drawings and specifications

Part number Connection Note
2D drawings
Download
Download
3D models
Download
Download
Tender text
CALEFFI, 127141***, AUTOFLOW. Compact automatic flow rate regulator, in line, with high resistance polymer cartridge. Flow rates: 0,02–0,06 m3/h - Δp range: 20–200 kPa - Accuracy: ± 15 %. Flow rates: 0,085–11,0 m3/h - Δp range: 15–200 kPa - Accuracy: ± 10 %. Connection: G 1/2" (ISO 228-1) F. Maximum working pressure: 16 bar. Medium temperature range: 0–100 °C. Maximum percentage of glycol: 50 %. Medium: water. Material: brass.
2D drawings
Download
Download
3D models
Download
Download
Tender text
CALEFFI, 127151***, AUTOFLOW. Compact automatic flow rate regulator, in line, with high resistance polymer cartridge. Flow rates: 0,02–0,06 m3/h - Δp range: 20–200 kPa - Accuracy: ± 15 %. Flow rates: 0,085–11,0 m3/h - Δp range: 15–200 kPa - Accuracy: ± 10 %. Connection: G 3/4" (ISO 228-1) F. Maximum working pressure: 16 bar. Medium temperature range: 0–100 °C. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions. Material: brass.
2D drawings
Download
Download
3D models
Download
Download
Tender text
CALEFFI, 127161***, AUTOFLOW. Compact automatic flow rate regulator, in line, with high resistance polymer cartridge. Flow rates: 0,02–0,06 m3/h - Δp range: 20–200 kPa - Accuracy: ± 15 %. Flow rates: 0,085–11,0 m3/h - Δp range: 15–200 kPa - Accuracy: ± 10 %. Connection: G 1" (ISO 228-1) F. Maximum working pressure: 16 bar. Medium temperature range: 0–100 °C. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions. Material: brass.
2D drawings
Download
Download
3D models
Download
Download
Tender text
CALEFFI, 127171***, AUTOFLOW. Compact automatic flow rate regulator, in line, with high resistance polymer cartridge. Flow rates: 0,02–0,06 m3/h - Δp range: 20–200 kPa - Accuracy: ± 15 %. Flow rates: 0,085–11,0 m3/h - Δp range: 15–200 kPa - Accuracy: ± 10 %. Connection: G 1 1/4" (ISO 228-1) F. Maximum working pressure: 16 bar. Medium temperature range: 0–100 °C. Maximum percentage of glycol: 50 %. Medium: water. Material: brass.
2D drawings
Download
Download
3D models
Download
Download
Tender text
CALEFFI, 127181***, AUTOFLOW. Compact automatic flow rate regulator, in line, with high resistance polymer cartridge. Flow rates: 0,02–0,06 m3/h - Δp range: 20–200 kPa - Accuracy: ± 15 %. Flow rates: 0,085–11,0 m3/h - Δp range: 15–200 kPa - Accuracy: ± 10 %. Connection: G 1 1/2" (ISO 228-1) F. Maximum working pressure: 16 bar. Medium temperature range: 0–100 °C. Maximum percentage of glycol: 50 %. Medium: glycol solutions. Material: brass.
2D drawings
Download
Download
3D models
Download
Download
Tender text
CALEFFI, 127191***, AUTOFLOW. Compact automatic flow rate regulator, in line, with high resistance polymer cartridge. Flow rates: 0,02–0,06 m3/h - Δp range: 20–200 kPa - Accuracy: ± 15 %. Flow rates: 0,085–11,0 m3/h - Δp range: 15–200 kPa - Accuracy: ± 10 %. Connection: G 2" (ISO 228-1) F. Maximum working pressure: 16 bar. Medium temperature range: 0–100 °C. Maximum percentage of glycol: 50 %. Medium: water, glycol solutions. Material: brass.

Applications

Pipe Sizer Caleffi
Pipe Sizer Caleffi

This application allows for sizing and making calculations for pipes and conduits carrying water or air, respectively for hydraulic or aeraulic plants.