Backflow preventer with multifunction geometry. BA type. Threaded union connections.
Product Description
Backflow preventer with multifunction geometry. BA type. Threaded union connections.
Complete with inlet strainer.
For in-line, horizontal or vertical installation.
Certified to EN 12729 standard.
Technical data
Medium temperature range:
0–65 °C
PN (Nominal pressure):
PN 10
Material:
dezincification resistant brass DR
Certifications









Download
Drawings and specifications
Part number | Connection | Note | DN |
---|---|---|---|
580004 | R 1/2" (EN 10226-1) M union |
- | DN 15 (body) |
2D drawings
3D models
Tender text
Backflow preventer with multifunction geometry. BA type. Threaded union connections.
Complete with inlet strainer.
For in-line, horizontal or vertical installation.
Certified to EN 12729 standard. connection: R 1/2" (EN 10226-1) M, union. Medium temperature range: 0–65 °C. PN (Nominal pressure): PN 10. DN: DN 15 (body). Material: dezincification resistant brass DR.
|
|||
580040 | R 1/2" (EN 10226-1) M union |
(DN 20 cartridge) | DN 15 (body) |
2D drawings
3D models
Tender text
Backflow preventer with multifunction geometry. BA type. Threaded union connections.
Complete with inlet strainer.
For in-line, horizontal or vertical installation.
Certified to EN 12729 standard. connection: R 1/2" (EN 10226-1) M, union. Medium temperature range: 0–65 °C. PN (Nominal pressure): PN 10. DN: DN 15 (body). Material: dezincification resistant brass DR.
|
|||
580050 | R 3/4" (EN 10226-1) M union |
- | DN 20 (body) |
2D drawings
3D models
Tender text
Backflow preventer with multifunction geometry. BA type. Threaded union connections.
Complete with inlet strainer.
For in-line, horizontal or vertical installation.
Certified to EN 12729 standard. connection: R 3/4" (EN 10226-1) M, union. Medium temperature range: 0–65 °C. PN (Nominal pressure): PN 10. DN: DN 20 (body). Material: dezincification resistant brass DR.
|
|||
580060 | R 1" (EN 10226-1) M union |
- | DN 25 (body) |
2D drawings
3D models
Tender text
Backflow preventer with multifunction geometry. BA type. Threaded union connections.
Complete with inlet strainer.
For in-line, horizontal or vertical installation.
Certified to EN 12729 standard. connection: R 1" (EN 10226-1) M, union. Medium temperature range: 0–65 °C. PN (Nominal pressure): PN 10. DN: DN 25 (body). Material: dezincification resistant brass DR.
|
|||
580070 | R 1 1/4" (EN 10226-1) M union |
- | DN 32 (body) |
2D drawings
3D models
Tender text
Backflow preventer with multifunction geometry. BA type. Threaded union connections.
Complete with inlet strainer.
For in-line, horizontal or vertical installation.
Certified to EN 12729 standard. connection: R 1 1/4" (EN 10226-1) M, union. Medium temperature range: 0–65 °C. PN (Nominal pressure): PN 10. DN: DN 32 (body). Material: dezincification resistant brass DR.
|