Motorised regulating unit for heating and cooling systems.
Product Description
Motorised regulating unit for heating and cooling systems.
Set up for CONTECA® (MI004) heat metering, with a template and adapters for direct immersion probes.
Regulation with sector three-way valve and 3-point actuator. Can be connected to digital regulators code 161010.
Bottom-up flow - boiler connection on RH side.
With insulation.
With auxiliary microswitch.
Technical data
Maximum working pressure:
10 bar
Medium temperature range:
5–100 °C
Electric supply:
230 V (AC)
Main centre distance:
125 mm
Certifications
Drawings and specifications
Part number | System side connection | Boiler side connection | Note |
---|---|---|---|
767662HE2 | G 1" (ISO 228-1) F inlet |
G 1 1/2" A (ISO 228-1) M end outlet |
Bottom-up flow - right-hand side flow |
Flow rate with available head 4 m.c.a.
2,2 m³/h
|
Type of pump
Para 25-9
|
||
2D drawings
3D models
Tender text
Motorised regulating unit for heating and cooling systems.
With insulation.
With auxiliary microswitch.
Set up for CONTECA® (MI004) heat metering, with a template and adapters for direct immersion probes.
Regulation with sector three-way valve and 3-point actuator. Can be connected to digital regulators code 161010.
Bottom-up flow - boiler connection on RH side. system side connection: G 1" (ISO 228-1) F, inlet. boiler side connection: G 1 1/2" A (ISO 228-1) M, end outlet. Maximum working pressure: 10 bar. Medium temperature range: 5–100 °C. Electric supply: 230 V (AC). Main centre distance: 125 mm. Flow rate with available head 4 m.c.a.: 2,2 m³/h. Type of pump: Para 25-9.
SCIP code
3bd77297-493c-4165-9e99-e0d535414066
|
|||
767664HE2 | G 1" (ISO 228-1) F inlet |
G 1 1/2" A (ISO 228-1) M end outlet |
Bottom-up flow - right-hand side flow |
Flow rate with available head 4 m.c.a.
2,2 m³/h
|
Type of pump
Para 25-9
|
||
2D drawings
3D models
Tender text
Motorised regulating unit for heating and cooling systems.
With insulation.
With auxiliary microswitch.
Set up for CONTECA® (MI004) heat metering, with a template and adapters for direct immersion probes.
Regulation with sector three-way valve and 3-point actuator. Can be connected to digital regulators code 161010.
Bottom-up flow - boiler connection on RH side. system side connection: G 1" (ISO 228-1) F, inlet. boiler side connection: G 1 1/2" A (ISO 228-1) M, end outlet. Maximum working pressure: 10 bar. Medium temperature range: 5–100 °C. Electric supply: 230 V (AC). Main centre distance: 125 mm. Flow rate with available head 4 m.c.a.: 2,2 m³/h. Type of pump: Para 25-9.
SCIP code
ef6162d5-5c29-4c0b-bf85-7600ba06404b
|